Do you have a question about the BAT-FLEX and is the answer not in the manual?
Questions and answers
Summary of Contents for Astrol Electronic BAT-FLEX
Page 1
BAT-FLEX Manual Rev. Remarks /changes created checked released Initial, ported 01.03.13 01.03.13 01.03.13 Corrected channel specification 21.08.14 21.08.14 Astrol Electronic AG reserves the right to change specifications without notice Bat FLEX Manual 1/19 AD-10069-007 Rev. 03...
Appendix B: BAT FLEX Small Connection Designation ............18 Labels ..........................19 11.1. Back side ........................19 11.2. Inside ..........................19 Order code ......................... 19 Astrol Electronic AG reserves the right to change specifications without notice Bat FLEX Manual 2/19 AD-10069-007 Rev. 03...
Turn the BatFlex device on, using the main switch on the front side. The device is now ready to communicate with the PC. Astrol Electronic AG reserves the right to change specifications without notice Bat FLEX Manual 3/19 AD-10069-007 Rev. 03...
This card is a compound consisting of two stacked BatFlex Small cards. This allows to use up to 8 channels with a single card slot. The full specification can be found in chapter 2.5.4. Astrol Electronic AG reserves the right to change specifications without notice Bat FLEX Manual 4/19 AD-10069-007 Rev.
The status label indicates if there are any errors or complications detected Astrol Electronic AG reserves the right to change specifications without notice Bat FLEX Manual 5/19 AD-10069-007 Rev. 03...
Page 6
Do not plug the Ethernet cable into the JTAG connector. The connectors have different pin counts, however, because of the RJ standard, they look very similar. Astrol Electronic AG reserves the right to change specifications without notice Bat FLEX Manual 6/19 AD-10069-007 Rev.
The reference output cable must not touch the case in any way. Connecting the reference output to the case will lead to wrong calibration of the device. Astrol Electronic AG reserves the right to change specifications without notice Bat FLEX Manual 7/19 AD-10069-007 Rev.
Network device port: Communication port ,default port is 16723 Communication mode has to be set to „Ethernet UDP/IP“. Astrol Electronic AG reserves the right to change specifications without notice Bat FLEX Manual 8/19 AD-10069-007 Rev. 03...
By right-clicking on the „Astrol-Box“ in the channel-list a window appears with some additional information about the selected device. There are also some buttons to calibrate, reset, search for new devices and update the firmware. Astrol Electronic AG reserves the right to change specifications without notice Bat FLEX Manual 9/19 AD-10069-007 Rev.
Data File because it contains all the essential information to visualize the results. This window shows the configuration page of a cyclovoltametric step Astrol Electronic AG reserves the right to change specifications without notice Bat FLEX Manual 10/19 AD-10069-007 Rev. 03...
Set target as next Go to next step. Step Action step Cond. invalid Check Conditions Cond. met Has Jump Target? Last Step? Astrol Electronic AG reserves the right to change specifications without notice Bat FLEX Manual 11/19 AD-10069-007 Rev. 03...
This step opens the output for a specific amount of time. The measurement editor overview: Inserting new steps to the program can be simply achieved by right-clicking at the desired position Astrol Electronic AG reserves the right to change specifications without notice Bat FLEX Manual 12/19 AD-10069-007 Rev.
It’s possible to track the previously mentioned execution pointer during a measurement by opening the „Schritte (Steps)“ window. Each measurement has its own control window Astrol Electronic AG reserves the right to change specifications without notice Bat FLEX Manual 13/19...
After saving the program one can proceed with the measurement and data analysis. Astrol Electronic AG reserves the right to change specifications without notice Bat FLEX Manual 14/19 AD-10069-007 Rev. 03...
The CCCC Software offers 4 simulation channels. They can be used to test a measurement flow. Keep in mind that these channels may not be completely accurate due to a simpler simulation algorithm. Astrol Electronic AG reserves the right to change specifications without notice Bat FLEX Manual 15/19 AD-10069-007 Rev.
The following parameters are essential, it`s recommended to copy it for further use: IPv4 Subnet Mask Default Gateway DNS Servers Click on Properties now. Astrol Electronic AG reserves the right to change specifications without notice Bat FLEX Manual 16/19 AD-10069-007 Rev. 03...
Page 17
For example www.google.ch will not show any result, the IP address (http://74.125.224.72/, Date: 6.1.2014) has to be used. Astrol Electronic AG reserves the right to change specifications without notice Bat FLEX Manual 17/19 AD-10069-007 Rev. 03...
Never connect different guard types, the device could be damaged! Guard- 1 Guard+ 1 Aux+ 1 Guard+ 1 The connector on the device side is a Sub-D 25 female Astrol Electronic AG reserves the right to change specifications without notice Bat FLEX Manual 18/19 AD-10069-007 Rev. 03...
Need help?
Do you have a question about the BAT-FLEX and is the answer not in the manual?
Questions and answers