J&M 631340 Electrical Installation page 2

Hoist/winch

Advertisement

the relay before connecting to the battery. Make sure the connection is good before testing the system.
CAUTION: If the wire becomes hot/warm after you attach it to the battery, or the reset breaker trips,
immediately disconnect and check the system for proper routing.
7) Mounting the Cord Hanger
Determine an accessible location for the handheld.
Mount the bracket using the #10 pan head screws.
Check that the rotation of the motor matches the
indicators on the handheld. If it is reversed, switch the
wires at the motor. Once everything is correct, re-attach
the box cover and secure down any cord between the
box and cord mount.
8) Routing the Cable (hoist only)
It is recommended that you unwind the Cable and cut it
to 25ft and then rewind it. This reduces the stress on the
motor and electrical components allowing a longer life span. Attach the upper pulley with the pin and clip
along with the cable to the end of the boom. The
pin must be rotated correctly to fit into the
groove so that the clip will fit. Attach the block &
tackle on the far end of the upper pulley and
loop the hook attached to the cable on the tab
at the end of the boom tube. Please note the
hook needs to be first clipped on at the top and
then rotated down into the correct position.
Note: (Do not remove the block and pulley, this
adds more load on the cable and may cause
damage over time.)
Contact J&M for assistance at 714-898-4259 or Info@PlumbingVans.com

Advertisement

loading