Download Print this page

Skipper ETNSLJB Operation And Installation Manual

100mm gate valve for echo sounder transducer

Advertisement

Quick Links

SKIPPER ETNSLJB
100mm GATE VALVE FOR ECHO
SOUNDER TRANSDUCER
Operation And Installation Manual
Edition 20070522
Skipper Electronics A/S
Ryensvingen 5
P.O.Box 151, Manglerud
0612 Oslo, Norway
www.skipper.no
Telphone
+47 23 30 22 70
Telefax
+47 23 30 22 71
E-mail: skipper@skipper.no
Co.reg.no: NO-965378847 -MVA

Advertisement

loading
Need help?

Need help?

Do you have a question about the ETNSLJB and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Skipper ETNSLJB

  • Page 1 SKIPPER ETNSLJB 100mm GATE VALVE FOR ECHO SOUNDER TRANSDUCER Operation And Installation Manual Edition 20070522 Skipper Electronics A/S Telphone +47 23 30 22 70 Ryensvingen 5 Telefax +47 23 30 22 71 P.O.Box 151, Manglerud E-mail: skipper@skipper.no 0612 Oslo, Norway Co.reg.no: NO-965378847 -MVA...
  • Page 2 Copying of this document, and giving it to others and the use or Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Communication of contents therof, are forbidden without express Mitteilung ihres Inhaltes nicht gestattet, soweit nicht ausdrücklich Authority. Offenders are liable to the payment of damages. zugestanden.
  • Page 3: Installation

    ECHO SOUNDER TRANSDUCER. INSTALLATION. The SKIPPER 100 mm Gate Valve Echo Sounder is used for installation of : 1: Echo Sounder Transducer type TGM 60-50-25L or TGM 50-200-25L. The SKIPPER 100 mm Gate Valve Echo Sounder is delivered assembled for transport.
  • Page 4 Check that the transducer sensor housing, when fully inserted, is flush with the lower surface of the bottom flange. If the above point are not met exactly, it is possible to adjust the height of the gate valve by inserting thicker or more than one “Klingersil”...
  • Page 5 REMOVAL OF ECHO SOUNDER TRANSDUCER UNIT The sensor unit is secured with 6 each 16 mm pinbolts with nuts and washers, and two 16mm nuts on each 16 x 300 mm safety bolts. There should be a split pin through the hole drilled near the top of the safety bolts. WARNING ! ON VESSELS WITH DEEP DRAFT, THE SEA PRESSURE ON THE SENSOR UNIT IS CONSIDERABLE, AND MAY PUSH THE UNIT UPWARDS, ONCE LOOSENED, WITH GREAT...
  • Page 6 REINSTALLATION OF ECHO SOUNDER TRANSDUCER UNIT. Before the sensor unit is reinstalled , please check that the O-ring on top of the intermediate element and also the water blocking O-ring inside the intermediate element, are free of damage and well greased. Grease the transducer unit with water resistant grease and insert it into the top of the intermediate element, pushing it as far down as it will go.