  • Page 1 Operating Instructions ® ISARIA PRO Compact Version V1.1 / 20. Januar 2020...
  • Page 2: Table Of Contents

    Gender-specific writing style AFETY Proper use/warranty Selecting personnel and required qualifications Organisational safety Safety information Dangers arising from the ISARIA 4.5.1 Danger through high magnetic forces on E sensor 4.5.2 Risk to safety in public and non-public road transport 4.5.3...
  • Page 3 ® Contents ISARIA PRO Compact PERATION General information on processing a task Operating scheme Creating a task Selecting task and starting Stopping a task Copying task Organisational data 7.7.1 Creating and saving organisational data 7.7.2 Data export of organisational data 7.7.3...
  • Page 4: Introduction

    We are glad you have opted for one of our products. We wish you flawless and successful operation. The distributing company is Fritzmeier Umwelttechnik under the name of ISARIA PRO Compact® (hereinafter called ISARIA). Distribution is handled via the company “CNH Industrial” with the brand “AgXtend”...
  • Page 5: Product Description

    This version of the instruction manual was created for the Müller Touch800 terminal. ISARIA is intended to precisely determine the nutrient condition of crops and is used for the sub- field optimisation (site-specific) of the application substance (spreadable fertiliser, liquids, crop protection products or growth regulators).
  • Page 6: Scope Of Delivery

    ® Product description ISARIA PRO Compact Scope of delivery fig. 2 Bracket for attaching the R sensor to the Operating and maintenance manual vehicle mirror Cable clips for secure routing of cables E sensor InCab T-Connect adapter cable R sensor, left vehicle side...
  • Page 7: Operation, Prior Knowledge

    General information on menu navigation/operation The ISARIA is operated via a touchscreen terminal The operating menu is largely self-explanatory. System statuses are displayed through symbols and plain text displays.
  • Page 8: Operating And Display Elements

    ® Notes on this manual ISARIA PRO Compact Operating and display elements LED, green There is measurement data from the sensors LED, blue Power supply established LED, blue Power supply established See instruction manual from manufacturer fig. 3 Notes on this manual General information This instruction manual contains all information and descriptions required to operate the system.
  • Page 9: Symbols Used

    ® Notes on this manual ISARIA PRO Compact Symbols used This manual contains the following symbols: CAUTION: warns of a risk to persons and materials. Disregarding information marked with this symbol may result in severe injury and material damage. ATTENTION: warns of material damage. Disregarding information marked with this symbol may result in material damage.
  • Page 10: Safety

    Personnel to be trained, taught, instructed or personnel currently undergoing general professional training must be supervised by experienced persons at all times when working on the ISARIA! All work on the ISARIA must be performed only by trained specialist personnel, and in compliance with all valid accident prevention regulations (UVV).
  • Page 11: Safety Information

    ® Safety ISARIA PRO Compact Safety information The ISARIA features the following safety information stickers. The operator must at all times ensure that these are complete and in perfect, legible and recognisable condition. Meaning Attachment location Dimension in mm ►...
  • Page 12: Dangers Arising From The Isaria

    Electromagnetic fields can affect and disturb pacemakers and defibrillators. The E sensor of the ISARIA (It. 2, fig. 1) is attached to the anchor plate (14) with a strong magnet. People and animals with a pacemaker and/or defibrillator must be kept at a sufficient safety distance away.
  • Page 13: Damage To The Environment Or Crops Due To Excessively High Application Quantities

    It may also be (as a result of incorrectly set parameters) that communication with the application device does not correspond to the requirements. For every change to the components connected to the ISOBUS, it must be ensured that the output quantity calculated by the ISARIA corresponds to the quantity which is actually output.
  • Page 14: Assembly

    ® Assembly ISARIA PRO Compact Assembly R sensors • Attach both R sensors (1) to the side on the vehicle cab and align Determine suitable assembly location. E.g. bracket of the rear mirror Important: fig. 4 - Assembly location must be selected in such a way that the R sensors are subjected to as little vibration as possible.
  • Page 15 ® Assembly ISARIA PRO Compact • If need be, select a reducer (40) which fits the attachment location and attach bracket (3) to attachment location. fig. 6 • Align R sensors as shown (direction of travel (A)) fig. 7 FRITZMEIER Umwelttechnik GmbH & Co. KG V1.1...
  • Page 16: Job Computer

    ® Assembly ISARIA PRO Compact Job computer • Position the job computer (4) in a suitable location in the interior of the cab (if need be, bolt down) in such a way that the cables can be easily connected. In doing so, ensure that the following distances (cable...
  • Page 17: E Sensor

    ® Assembly ISARIA PRO Compact E sensor Attaching E sensor (2) to the roof of the vehicle cab • Attach metal plate (14) to a suitable location (adhesive strip ATTENTION Risk of injury due to high magnetic forces. The magnet on the underside of the E sensor (2) is very strong.
  • Page 18: Cables

    ® Assembly ISARIA PRO Compact Cables 5.4.1 R sensors <=> E sensor • Connect resistors (5) to the plugs (36) of the R sensors (1) • Connect extension cable (6) to resistor (5) and connect with E sensor (2). Observe connections:...
  • Page 19: E Sensor <=> Job Computer

    ® Assembly ISARIA PRO Compact 5.4.2 E sensor <=> Job computer • Connect connection cable of job computer (7) to plug-in location (C) of the E sensor (2), guide to job computer • Connect connection cable of job computer (7) to job computer (16) fig.
  • Page 20: Job Computer <=> Terminal

    ® Assembly ISARIA PRO Compact 5.4.3 Job computer <=> Terminal • Connect plug (A) of connection cable of job computer (7) to the terminal (connection C on the TOUCH800) fig. 15 5.4.4 Job computer <=> ISOBUS • Connect plug (B) of connection cable of job computer (7) to a free ISOBUS plug-in location (C) fig.
  • Page 21: Initial Commissioning

    ® Initial commissioning ISARIA PRO Compact Initial commissioning Configuring TOUCH800 • Connect TOUCH800 to power supply and switch it on 6.1.1 Operating mode • Set operating mode to “Extended”. To do this: <Tasks menu> (A) ►<Settings> (B) ► <Operating Mode> (C) ► <Extended> (D) ► <OK> (E) fig.
  • Page 22: Gps Connection

    ® Initial commissioning ISARIA PRO Compact 6.1.2 GPS connection • Set baud rate to “9600”. To do this: <Service> (A) ►<GPS> (B) ► <Baud rate> (C) ► <9600> (D) ► <OK> (E) ► <OK> • Restart the terminal fig. 19 22 / 48 FRITZMEIER Umwelttechnik GmbH &...
  • Page 23: Initialising Storage Medium, Usb Data Medium

    ® Initial commissioning ISARIA PRO Compact 6.1.3 Initialising storage medium, USB data medium • Ensure that the original USB stick (included in delivery) is connected to the terminal • <Tasks menu> (A) ► <Settings (B) ► <USB> (C) ► Loading data fig.
  • Page 24: Operation

    General information on processing a task General A task ensures communication between ISARIA and the application device via ISOBUS. Recurring activities or information regarding a field can thus be saved and, if need be, used. If different application devices are used, they can be selected via prepared tasks.
  • Page 25 ® Operation ISARIA PRO Compact Carrying out a calibration run Required Function Section Parametrise ISARIA Provisions for calculating the application quantity ▼ depending on the level of crop growth Switch on calibration Measurements can be recorded 7.10 ▼ Drive Recording of measurements FRITZMEIER Umwelttechnik GmbH &...
  • Page 26: Creating A Task

    ® Operation ISARIA PRO Compact Creating a task • <Tasks menu> (A) ► <Tasks> (B) ► <create new task> (C) ► a new task with the suggested name (D = date, time) is prepared. The data fields (E) for this new task can be edited fig.
  • Page 27 ® Operation ISARIA PRO Compact • <Implements> (A) ► <Add implement> (B) ► <ISARIA Basic> (D) • <add implement> (B) again ► <Düngerstreuer (fertiliser spreader)> (C, if available) • <Back> (E) ► <Yes> Save changes; the task has been created fig.
  • Page 28: Selecting Task And Starting

    ® Operation ISARIA PRO Compact Selecting task and starting • As described in 7.3, display the list of tasks (B, fig. 21) • <Select task> (A) ► <Task start> (B) ►The task is being started; the task symbol is indicated with a green dot fig.
  • Page 29: Copying Task

    ® Operation ISARIA PRO Compact Copying task • As described in “7.4 Selecting task and starting”, navigate to the list of recorded tasks • Select a task; the data fields of the task are available for editing • <Copy task>, a new task with the same content will be created. The task name is identical, however is marked with a * (asterisk) before the first character in the character sequence FRITZMEIER Umwelttechnik GmbH &...
  • Page 30: Organisational Data

    ® Operation ISARIA PRO Compact Organisational data When creating tasks, in addition to data which is relevant to outputting the application substance, organisational data (name, address, company, field (site-specific), etc.) can also be saved and imported/exported. 7.7.1 Creating and saving organisational data •...
  • Page 31: Data Export Of Organisational Data

    ® Operation ISARIA PRO Compact 7.7.2 Data export of organisational data • <Tasks menu> (A) ► <Logout> (B) • Adopting new tasks: - Yes (C) = the organisational data located on the terminal (see 7.7.1) will be copied together with the task data to the stick. At the same time, task data saved on the stick is copied to the terminal.
  • Page 32: Data Import Of Organisational Data

    ® Operation ISARIA PRO Compact 7.7.3 Data import of organisational data Requirement: USB stick with data suitable for the terminal is connected with the terminal, the <Logout> button (B in fig. 26) is not greyed out. • <Tasks menu> (A) ► <Logout> (B in fig. 26) ► Yes (C in fig. 26), the data is imported from the...
  • Page 33: Parametrising Isaria

    ® Operation ISARIA PRO Compact Parametrising ISARIA • <CXP> (A) ► Acknowledge GPS signal note with OK (B)* ► CropXplorer Basic main menu is opened • <Operation menu> (C) * is only displayed if the menu is opened for the first time after starting up the terminal fig.
  • Page 34: Basic Data For Fertilisation I

    ® Operation ISARIA PRO Compact 7.8.1 Basic data for fertilisation I Growth stage - Grain, bolting II (EC 37-39) Fertiliser strategy - Grain, quality dose ( EC - 47-55 ) - Balancing: N supply - Rape main shoot (~EC 30)
  • Page 35: Basic Data For Fertilisation Ii

    ® Operation ISARIA PRO Compact 7.8.2 Basic data for fertilisation II Target quantity Enter value relevant to crop production. Take note of the relevant fertiliser ordinance and subsequent delivery (soil conditions). Example For an N supply (A) measurement (index) of 20.4, 90 kg N/ha is used.
  • Page 36: Key Data Of Application Device

    ® Operation ISARIA PRO Compact Key data of application device • <CXP> (A, fig. 27) ►CropXplorer Basic is displayed • <Settings> (A) • <Application device> (B) ► Setting options: - C = spreader or sprayer - Deposit point of the fertiliser (metres)
  • Page 37: Calibration Run

    Calibration run General To calculate the application value, the measurements from the sensors are used. These measurements are taken via a calibration run with the ISARIA. Carrying out a calibration run • <Operation menu> (C, fig. 27) ►Operation menu is shown •...
  • Page 38: Notifications On The Screen While Driving

    ® Operation ISARIA PRO Compact 7.11 Notifications on the screen while driving 7.11.1 Switching notifications on and off • <CXP> (A, fig. 27) ►CropXplorer Basic is displayed • <Settings> (A) ► The display of the measurements in the operation menu can be set * range fig.
  • Page 39: Status And Error Notifications

    ® Operation ISARIA PRO Compact 7.11.2 Status and error notifications Maximum target quantity exceeded Maximum target quantity undershot Automatic operation activated Manual operation activated Error: no communication with the E sensor Error: no communication with one of the R sensors...
  • Page 40: Output Of Fertiliser

    ® Operation ISARIA PRO Compact 7.12 Output of fertiliser 7.12.1 Automatic operation In automatic operation* (notification (2, fig. 33)) the application quantity can be adjusted at any time during the fertilisation run (for preparation see 7.2 / 24). For this, increase (A) or lower (B) the range.
  • Page 41: The Most Important Symbols And Their Meaning

    ® Operation ISARIA PRO Compact 7.13 The most important symbols and their meaning Task has pause status. For when an additional task is started while this task is still running Task has been started Task has been stopped Task has been created but has not yet been started...
  • Page 42 ® Operation ISARIA PRO Compact 7.14 Table with range recommendations (Values saved in the ISARIA which can be changed via the settings of the task) Range recommendations in automatic mode N fertilisation, grain, 3 doses Schedule Growth stage Range recommendation...
  • Page 43: Special Settings

    ® Special settings ISARIA PRO Compact Special settings Biomass – calibrating threshold value The biomass threshold value (C) indicates the index value (only for biomass) below which the system no longer outputs the amount of fertiliser calculated from the sensor values. Below this value, the manually set, specific quantity (D) is output.
  • Page 44 ® Special settings ISARIA PRO Compact Calibrating • <Start> (F) and drive on a representative stretch; the sensor values are calculated • <Save> (G); the threshold value (C) is saved • If need be, adjust “Specific amount” (H) Additional functions...
  • Page 45: Connecting And Disconnecting Usb Storage Medium

    ® Special settings ISARIA PRO Compact 8.1.1 Connecting and disconnecting USB storage medium • Insert original USB stick (included in delivery) to terminal <Service> (A) If the USB symbol is shown in colour, the USB stick is ready for use. Organisational data can be saved as well as exported and imported (see chapter 7.7)
  • Page 46: Troubleshooting

    ® Troubleshooting ISARIA PRO Compact Troubleshooting Version number of the installed software • <CPX> (A, fig. 27) ►CropXplorer Basic is displayed • <Settings> ► <Information> ► manufacturer information and version number of the software can be seen fig. 38 46 / 48 FRITZMEIER Umwelttechnik GmbH &...
  • Page 47: Possible Errors And How To Fix Them

    ® Maintenance ISARIA PRO Compact Possible errors and how to fix them See section, figure/page Error Cause/solution ▼ - Manual operation is activated/switch on automatic fig. 33 / 39 operation - No task has been started/start task 7.4 / 28...
  • Page 48: Technical Data

    ® Technical data ISARIA PRO Compact Technical data Dimensions/weight Dimensions (mm, approx.) Weight (kg, approx.) R sensor with bracket 132 x 186 x 188 E sensor 215 x 224 x 99 Job computer 130 x 95 x 40 11.0 Case (with all assemblies and...