  • Page 1 OPERATION AND INSTALLATION Cylinder and hydraulic module » HSBB 200 S (GB)
  • Page 2 16.1 Dimensions and connections  18 16.2 Hydraulic diagram  19 16.3 Wiring diagram  20 16.4 Details on energy consumption  22 16.5 Data table  22 GUARANTEE | ENVIRONMENT AND RECYCLING | HSBB 200 S (GB) www.stiebel-eltron.com...
  • Page 3 Failure to observe this information will result in serious injury or death. WARNING Failure to observe this information may result in serious injury or death. CAUTION Failure to observe this information may result in non-seri- ous or minor injury. www.stiebel-eltron.com HSBB 200 S (GB) |...
  • Page 4 - WPL 15 in summer. - HPA-O 3-8 CS Plus - HPA-O 7 Premium The system is controlled by means of the integral heat pump manager. Please observe the heat pump manager operating and installation instructions. | HSBB 200 S (GB) www.stiebel-eltron.com...
  • Page 5 - FET remote control the type plate (000000-0000-000000). Further accessories - Remote control for heating operation No.: 000000-0000-000000 - High limit safety cut-out STB-FB - Pressure hoses - Water softener HZEA - Segmented anode Made in Germany www.stiebel-eltron.com HSBB 200 S (GB) |...
  • Page 6 The minimum side clearances can be swapped to left or right. 10.2 Transport and handling Material losses Store and transport the appliance at temperatures be- tween -20 °C to +60 °C. f Remove the 2 screws on the cover. f Lift the cover. | HSBB 200 S (GB) www.stiebel-eltron.com...
  • Page 7 There must be no shut-off valve between the heat gen- erator and the safety valve. www.stiebel-eltron.com HSBB 200 S (GB) |...
  • Page 8 To avoid damage as a result of scaling, it may be necessary to soften or desalinate the fill water. The fill water limits specified in chapter "Specification / Data table" must always be observed. f Recheck these limits 8-12 weeks after commissioning and during the annual system service. | HSBB 200 S (GB) www.stiebel-eltron.com...
  • Page 9 (see chapter "Specifi- cation / Data table"). If necessary reduce the flow rate at the butterfly valve of the safety assembly. f Carry out a tightness check. f Check the safety valve. www.stiebel-eltron.com HSBB 200 S (GB) |...
  • Page 10 Note Permission to connect the appliance may need to be ob- tained from your local power supply utility. Material losses Close the quick-action air vent valve again after venting. | HSBB 200 S (GB) www.stiebel-eltron.com...
  • Page 11 Control voltage Material losses f Only connect energy efficient circulation pumps ap- proved by us to the pump connections. XD01.2 Heat pump enable signal Enable signal www.stiebel-eltron.com HSBB 200 S (GB) |...
  • Page 12 Earth X1.18 CAN (connection for FET remote control and CAN B ISG Internet Service Gateway) X1.19 CAN (connection for heat pump and WPE heat CAN A pump extension)     AA01 (WPM) | HSBB 200 S (GB) www.stiebel-eltron.com...
  • Page 13 In the case of temporary faults, the output switches the signal through for a specific time. In the case of faults that result in a permanent appliance shutdown, the output switches through permanently. www.stiebel-eltron.com HSBB 200 S (GB) |...
  • Page 14 Remove the cover (see chapter “Installation / Removing / fit- ting the front casing”). f Insert the temperature sensor into the sensor well “Sensor heat pump cooling, optional” from behind. f Connect the temperature sensor to AA01-X1.11. | HSBB 200 S (GB) www.stiebel-eltron.com...
  • Page 15 With the FET remote control you can adjust the set room temper- ature for the heating circuit by ± 5 °C and change the operating mode. f Connect the remote control to AA01-X1.2. 1 High limit safety cut-out reset button www.stiebel-eltron.com HSBB 200 S (GB) |...
  • Page 16 Draining the DHW cylinder"). f If you take the system out of use, set the heat pump manager to standby so that the safety functions that protect the appli- ance (e.g. frost protection) remain active. | HSBB 200 S (GB) www.stiebel-eltron.com...
  • Page 17 0.3 Ω. If it is not possible to insert a rod anode from above, install a segmented anode. f Decide the intervals in which further checks should be car- ried out. www.stiebel-eltron.com HSBB 200 S (GB) |...
  • Page 18 Cold water inlet Male thread DHW outlet Diameter DHW circulation Male thread G 1/2 Safety assembly drain Diameter T&P valve Heat pump flow Diameter Heat pump return Diameter Heating flow Diameter Heating return Diameter | HSBB 200 S (GB) www.stiebel-eltron.com...
  • Page 19 (i.e. no elbows or bends) Pressure drop of each elbow or bend Connection dimensions Safety assembly connection Expansion valve end connection Expansion vessel connection, male, BSP G 1 A Tundish inlet connection Tundish outlet connection www.stiebel-eltron.com HSBB 200 S (GB) |...
  • Page 20 Connector, CAN A (WP connection) MA10 Motor, heating circuit pump (not for HSBB or TSBB eco) AA01-X1.2 Connector, CAN B (FET/ISG connection) MA14 Motor, buffer charging pump (PWM/1-10V) AA01-X1.3 Connector, outside temperature sensor MA15 Motor, diverter valve, heating/DHW | HSBB 200 S (GB) www.stiebel-eltron.com...
  • Page 21 AA01-X2.14 Connector, mixer, heating circuit 2 AA07-X70 Connector, switching, pump, heating circuit PWM/1-10V (X2.14.1 Mixer OPEN/X2.14.2 Mixer CLOSE) AA07-X71 Not assigned AA01-X2.15 Connector, mixer, heating circuit 3 AA07-X72 Connector, CAN bus (X2.15.1 Mixer OPEN/X2.15.2 Mixer CLOSE) EB01-X59 Terminal, MFG www.stiebel-eltron.com HSBB 200 S (GB) |...
  • Page 22 Specification 16.4 Details on energy consumption Product datasheet: DHW cylinder to regulation (EU) no. 812/2013 HSBB 200 S (GB) set 236916 Manufacturer STIEBEL ELTRON Supplier’s model identifier HSBB 200 S (GB) Set Energy efficiency class Standby losses Cylinder capacity 16.5 Data table...
  • Page 23 | GUaraNTEE | ENVirONmENT aND rECYCliNG HSBB 200 S (GB) set Values Expansion vessel volume Expansion vessel - pre-charge pressure 0.15 Nominal design flow rate of heating system at A-7/W35 and 7 K m³/h Heating flow rate (min.) m³/h Safety assembly, max.
  • Page 24 Deutschland Verkauf Tel. 05531 702-110 | Fax 05531 702-95108 | info-center@stiebel-eltron.de STIEBEL ELTRON GmbH & Co. KG Kundendienst Tel. 05531 702-111 | Fax 05531 702-95890 | kundendienst@stiebel-eltron.de Dr.-Stiebel-Straße 33 | 37603 Holzminden Ersatzteilverkauf Tel. 05531 702-120 | Fax 05531 702-95335 | ersatzteile@stiebel-eltron.de Tel.