ASYS Totech EU SUPER DRY XSDB-1402-53 1416 201 Operation Manual

Applies to all cabinets of the -24, -54 and -57 series with touchscreen

Advertisement

O peration Manual Touchscreen
Applies to all cabinets of the -24, -54 and -57
(From LOGO software version upward of 1-24)
OPERATING THE DEVICE
All mechanical and electrical connections should be checked for tight fit and tightness prior to
commissioning, as well as to remove any soil.
Insert the plug into a grounded electrical outlet. If the device does not start instantly, it is in the
standby state. Please press the activation icon on the screen.
The initialization program of the cabinet now starts. When the initialization is complete, the display
shows the home screen and the fans start running.
series with Touchscreen

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Totech EU SUPER DRY XSDB-1402-53 1416 201 and is the answer not in the manual?

Questions and answers

Summary of Contents for ASYS Totech EU SUPER DRY XSDB-1402-53 1416 201

  • Page 1 ​ O peration Manual Touchscreen Applies to all cabinets of the -24, -54 and -57 series with Touchscreen (From LOGO software version upward of 1-24) OPERATING THE DEVICE All mechanical and electrical connections should be checked for tight fit and tightness prior to commissioning, as well as to remove any soil.
  • Page 2: Table Of Contents

    ​ O peration Manual Touchscreen OPERATING THE DEVICE 1. HOME DISPLAY 1.1 Regeneration 2. ALARM Use [Delete] to delete the complete alarm list. 3. TIMER (OPTION) 3.1 COUNTDOWN 3.2 FLT-RESET 4. GRAPH DISPLAY MENU 5. SERVICE 6. SETTINGS 6.1 SETTINGS 1/4 6.1.1 SETPOINT HUMIDITY 6.1.2 HUMIDITY ALARM LIMIT 6.1.2.1 ALARM...
  • Page 3 ​ O peration Manual Touchscreen 11.2 CHANGE THE IP ADDRESS OF THE DISPLAY 11.3 SELECT THE LOGO! BASE MODULE IP ADDRESS 12. Calibration 13. Maintenance 14. Troubleshooting 14.1 For malfunction 14.2 Measuring faults 14.3 Communication error via Ethernet 14.4 Display indicates “BM no resp Press ESC” 14.5 No indication on Display 14.6 Logic module and extension module checking 14.7 Humidity too high...
  • Page 4: Home Display

    ​ O peration Manual Touchscreen 1. HOME DISPLAY The display shows the relative humidity and temperature inside the cabinet / room in the left window. In the right-hand window you will find the displayed setpoints with arrows and the remote display at the bottom, as well as a bar graph for the current measured values in direct comparison.
  • Page 5: Alarm

    ​ O peration Manual Touchscreen 2. ALARM If an alarm is triggered, the display background flashes red. Use the [Alarm] key to go to the alarm display. All alarms with date, time and type are recorded from start to end. Press [Alarm Acknowledge] to reset the alarm delay.
  • Page 6: Graph Display

    ​ O peration Manual Touchscreen 4. GRAPH DISPLAY With this display, a trend graph for humidity and temperature profile is recorded. The display shows the relative humidity (blue) and temperature (red) as a trend graph. The dashed lines indicate the respective alarm limits. The zoom buttons allow you to adjust the displayed time window.
  • Page 7: Menu

    ​ O peration Manual Touchscreen MENU 5. SERVICE The service function is used to set the control parameters and is used exclusively by the manufacturer. Access only with service password. 6. SETTINGS Press the [Settings] key in the menu to enter the password prompt. Here you have the option to display only the settings (white representation of the values), or by entering the security code via Enter to set the values (blue representation of the values).
  • Page 8: Setpoint Humidity

    ​ O peration Manual Touchscreen 6.1.1 SETPOINT HUMIDITY In the "Humidity" setpoint menu, the desired relative humidity is entered as a percentage when the active drying is stopped. If the setpoint exceeds 15 minutes, the device automatically performs a regeneration. If "0"...
  • Page 9: Settings

    ​ O peration Manual Touchscreen 6.2 SETTINGS 2/4 6.2.1 OFFSET, LOCK, FIRMWARE Pressing [Next] will bring you to the next page. Here you can calibrate the sensor values by offset and also assign a password which can be used to protect the setting values. On this page is the [USB Boot] function.
  • Page 10: Settings

    ​ O peration Manual Touchscreen 6.3 SETTINGS 3/4 6.3.1 SYSTEM TIME, DATA LOGGER Continue to the third setting page by pressing [Next]. The current system time is displayed and you have the option to change it. To do this, activate the value to be changed under "​...
  • Page 11: Settings

    ​ O peration Manual Touchscreen 6.4 SETTINGS 4/4 MANUAL REGENERATION AND REGENERATION TIMER Continue to the fourth setting page by pressing [Next]. This page contains the regenerations timer. Here you can define up to three times, in which a regeneration is to be started. Dynamic regeneration remains active so that additional generations are performed automatically.
  • Page 12: Standby

    ​ O peration Manual Touchscreen 8. STANDBY To put the drying cabinet in standby mode, press the [Standby] button via [Menu] and then [Activate standby]. While the standby mode is activated, the backlighting of the display and the drying unit are deactivated.
  • Page 13 ​ O peration Manual Touchscreen...
  • Page 14: Networking Configuration

    ​ O peration Manual Touchscreen 11. NETWORKING CONFIGURATION ATTENTION: The user can only use the configuration menu for the settings described in this manual. Any further changes can lead to a malfunction! The drying cabinet or drying unit is pre-configured from the factory with the following IP settings. To establish a connection to your network, the address configuration must be adapted accordingly.
  • Page 15: Select The Logo! Base Module Ip Address

    ​ O peration Manual Touchscreen 11.3 SELECT THE LOGO! BASE MODULE IP ADDRESS To make sure the display is connected to the LOGO! Base module in the drying unit, the IP address of the base module has to be specified in the display: To do this, go to the [Setting] menu on the 3rd page and press [Offline].
  • Page 16: Troubleshooting

    ​ O peration Manual Touchscreen 14. Troubleshooting 14.1 For malfunction ✓ Disconnect device from power supply completely, and restart after 10 seconds. ✓ Check logic module and extension module as described under item 9.6. 14.2 Measuring faults ✓ Unplug the sensor and check plug connector. ✓...
  • Page 17: Humidity Too High

    ​ O peration Manual Touchscreen 14.7 Humidity too high ✓ At first startup, wait at least 24 hours for the cabinet to stabilize. ✓ The cabinet is in a regeneration cycle, it is normal the humidity will rise during this procedure. ✓...
  • Page 18: Warranty And Liability

    ​ O peration Manual Touchscreen 15. Warranty and Liability 15.1 Warranty and liability Principally, we apply our "General Terms & Conditions", which the operator has been provided with upon contract conclusion at the latest. Warranty and liability claims in relation to personal injury and property damage shall be excluded if the same arise from one or more of the causes below: ✓...
  • Page 19: Guidelines For The Rma Procedure Of Totech Europe B

    ​ O peration Manual Touchscreen 15.5 Guidelines for the RMA procedure of Totech Europe B.V. Please provide us as much as possible details to speed up the process. ✓ Navigate to our service portal at ​ h ttp://service.superdry-totech.com/ ✓ Totech Europe B.V. will only accept tickets filed in our service portal. ✓...
  • Page 20: Serial Numbers

    ​ O peration Manual Touchscreen 16. Serial numbers 16.1 Cabinet serial numbers Explanation how the serial number of the cabinet is identified: 16.2 Dry-unit serial numbers Explanation how the serial number of the Drying Unit is identified:...
  • Page 21: Ce-Declaration

    ​ O peration Manual Touchscreen 17. CE Declaration With this writing, we: Totech Europe BV Paxtonstraat 11 8013 RP Zwolle That the following Dry Cabinets are fitted with U-5003 Drying Unit: MSD 1222-54, HSD series, XSD series, XSDB series, XSDC series, XSDR series, SDR series confirm that the drying cabinet described corresponds with the fundamental safety and health demands of the following EC instructions: EN55011: 1998+A1:1999+A2:2002...

This manual is also suitable for:

Totech eu super dry u-5003 i-3315003

Table of Contents