Operating manual Table of contents INTRODUCTION ......................... 3 DESCRIPTION AND OPERATION OF THE PRODUCT ..........4 Description ..........................4 Technical specifications ......................4 Structure and operation of the Product .................. 6 Measurement instruments, tools and appliances ..............13 Marking and sealing ......................14 Packaging ..........................
This operating manual (hereinafter referred to as OM) is intended to describe structure, operating principles, technical service and usage of Analog-to-digital convert- er ADPC-101 (hereinafter referred to as the Product, ADPC-101). In addition to the instructions given in this document, the safety regulations and rules applicable in the field shall be observed.
Operating manual DESCRIPTION AND OPERATION OF THE PRODUCT 1.1 D ESCRIPTION The Product ensures Analog-to-digital conversion of obsolete signals from gy- rocompasses and logs in NMEA 0183 sentences and transmission of these data to the corresponding navigational equipment. The Product is used on the ships equipped with gyrocompasses and logs. They do not output current data in NMEA 0183 sentences (IEC 61162) to navigational equipment, which requires course and speed data in digital format.
Page 5
Analog-to-digital converter ADPC-101 log with closing contact interface. Technical specifications of the Product are represented in Table 1. Table 1 – General technical specifications of the Product Parameter Value Power supply 9.6…36.0 Input voltage with galvanic isolation, V DC...
TRUCTURE AND OPERATION OF THE RODUCT 1.3.1 The Product is manufactured in metal casing where a grounding stud and connection ports are located, see Figure 1. Figure 1 – ADPC-101 external view The Product structure includes functional elements, see Table 2. v.4.17...
Page 7
Analog-to-digital converter ADPC-101 Table 2 – Functional elements Type, standard size, Pos. № Elements Description identifier Main point grounding element of the М4х15 Grounding stud Product To connect power supply and external МG-16 Cable gland equipment – To display data «1»...
Page 8
Operating manual – threshold voltage approx. 6 V. DIP-switch «J10» status: а) – ADPC-101 device RS-422/485 channel; – ADPC-101 middle device RS-422/485 channel. Connectors «J9», «J1» (see Figure 5) are used for device configuration at manu- facturing stage and not used during operation.
Page 9
Analog-to-digital converter ADPC-101 Figure 2 – Connection diagram of selsyn type gyromcompass...
Page 10
Operating manual Figure 3 – Connection diagram of stepper type gyromcompass v.4.17...
Page 11
Analog-to-digital converter ADPC-101 Figure 4 – Connection diagram of stepper type gyrocompass with common positive...
Page 12
Operating manual Figure 5 – Terminals layout on the Product’s printed circuit board Table 3 – Assignment of the Product’s port terminals Terminal № Connector Description «CS1+» «CS1–» «CS2+» «CS2–» «J1» To connect gyrocompass «CS3+» «CS3–» «CSR+» «CSR–» «LOG+» «LOG–» «J2»...
Analog-to-digital converter ADPC-101 Terminal № Connector Description «RX» «TX» «GND» To connect data receivers «TX–» «J3» «TX+» «GND» «+24V» To connect power supply «GND» 1.4 M EASUREMENT INSTRUMENTS TOOLS AND APPLIANCES Consumables required for the TS are represented in Table 4.
Operating manual 1.5 M ARKING AND SEALING The Product has a nameplate indicating name, input voltage, power consump- tion, protection degree, weight, serial number and date of manufacturing. The sealing of the Product is not provided. 1.6 P ACKAGING At the time of delivery the Product is packed in a corrugated board box and in- ner packaging (air bubble film) ensuring its transportation and storage at the warehouse.
Analog-to-digital converter ADPC-101 INTENDED USE OF THE PRODUCT PERATIONAL CONSTRAINTS Select the installation site in compliance with operational constraints (operating temperature and protection degree – IP). Caution! Distance between the installation site and magnetic compass shall not be less than 1 m! SAGE PREPARATIONS 2.2.1 Safety features...
Operating manual 2.2.4 To switch the Product off: a) transfer circuit breakers of main power switchboard to «OFF» position; b) disconnect de-energized cables. SAGE OF THE PRODUCT 2.3.1 As soon as power is supplied, the Product transfers to the mode of course and speed data display;...
Page 17
Analog-to-digital converter ADPC-101 c) enter course data using digit buttons and point «.»; d) press «ENTER». The LCD returns into display mode of current course data from gyrocompass and log; sound signaling stops. To edit or delete the last character of the input value, you may use «CLEAR»...
Page 18
Operating manual «1» «3» «2» «0» «SHIFT» «.» «3» «ENTER» 2 To enter 152.4 and then change digit 2 to 8, press: «1» «1» «5» «2» «SHIFT» «.» «4» «SHIFT» «CLEAR» «CLEAR» «CLEAR» «8» «SHIFT» «.» «4» «ENTER». 2.3.4 In the mode of additional display of inputs status, LCD shows logic signal states on the Product inputs, which might be useful during installation operations, see Figure 8.
Page 19
Analog-to-digital converter ADPC-101 2.3.6 In mode of current ship turn rate display LCD shows current ship turn rate. When switching to this mode, the LCD lower line with current course data starts showing ship rate turn data, see Figure 9.
Page 20
Operating manual a) COM baudrate – baudrate: 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 76800, 115200, 230400 bit/s; b) COM parity – parity bit: NO, EVEN, ODD; c) COM stop bits – stop bits: 1, 2. 2.3.11 Keyboard setting “Button click” – sound key stroke: Yes, No. 2.3.12 Display setting “Display refresh”...
Page 21
Analog-to-digital converter ADPC-101 IIVTG - $IIVTG,,,,,x.x,N,,*cs; IIVBW - $IIVBW,x.x,,A,,,*cs; SIVHW - $SIVHW,x.x,T,,,x.x,N,,*cs (mixed format – course and speed are out- put in one line); VMVBW - $VMVBW,x.x,,A,,,A,,V,,V*cs (NMEA v 2.3); Note – «сs» is a checksum.
Operating manual TECHNICAL SERVICE OF THE PRODUCT 3.1 G ENERAL DESCRIPTION The Product’s TS shall be provided by the staff acquainted with its composition, structure and operation features. In order to provide safe and reliable operation of the Product, the staff shall maintain semi-annual TS.
Analog-to-digital converter ADPC-101 Table 6 – CL №1. Visual check of the Product Man-hours To be done Routine per 1 Prod- 1 check completeness and appearance of the Product; mechanical damage, paint defects must be absent; marking plates shall be present; legends are to be read easily;...
Operating manual CURRENT REPAIR OF THE PRODUCT 4.1 G ENERAL DESCRIPTION To provide diagnostics of the problems and defects, use information in Table 8. Please contact the Manufacturer’s service centre in case of other defects, which cannot be traced. 4.2 S AFETY FEATURES Any repair works shall be provided by personnel examined and received proper qualifications in the area of the occupational safety.
Page 25
Analog-to-digital converter ADPC-101 Table 8 – The list of possible malfunctions and troubleshooting Malfunction Possible reasons To be done No mains power Supply mains power The Product does not Power cable is not connected Connect the power cable switch on...
Operating manual STORAGE The units must be stored in packaging inside areas complying with the required storage conditions (+ 5…+ 40 °С) with the concentration of dust, oil, moisture and ag- gressive impurities in the air within the required limits for the working areas of produc- tion facilities.
Analog-to-digital converter ADPC-101 TRANSPORTATION The Product must be transported in the Manufacturer's transportation package in closed means of transport. Types of shipment: а) motor vehicle and railroad transportation in closed means of transport (cov- ered cars, multipurpose containers); b) air transportation (in sealed and heated compartments);...
Operating manual DISPOSAL New equipment, the parts of the Product damaged during operation, and any overage equipment must not be disposed as standard household wastes, since they con- tain the materials suitable for re-use. Decommissioned and non-used components of the Product must be delivered to a special waste disposal center licensed by local authorities.
Need help?
Do you have a question about the ADPC-101 and is the answer not in the manual?
Questions and answers