Standard Repair Process Detail Technical Manual
symptom
Content
SET Model
43UK63
EAY64529501, LGP43DJ-17U1

Power Check Sequence

1. AC input Check : SK100 (100~240Vac)
2. PWR-ON Check :
- SET On : above 3V
- SET St-by : 0V
3. 13.2V DC Check :
- SET On : 13.2V
- SET St-by : 7.8V
4. MS Level Check : MS
MS Level
Range [V]
MS (0V)
0 ~ 0.25
MS (2V)
1.75 ~ 2.25
MS (3V)
2.75 ~ 3.25
※ Home mode : General Customer
Store mode : use Store
5. LED voltage Check : P801, Pin 1-7
Picture Condition : VIVID (Back light 100)
Min
61.2V
all condition meets, Power Board OK.
Error
B. Power error _No power

Check power input voltage and ST-BY 7.8V

Power P/N, Name
LED On/Off
Off
On (Home mode)
On (Store Mode)
Max
74.8V
Established
P801
SK100 (AC input)
date
Revised
date
P201
Copyright © 2018 LG Electronics Inc. All rights reserved.
Only for training and service purposes.
A18