Page 4
fi lter that separates waveforms of the signals and rejects the ones that are diff erent from a “classic” shape of an ESD event. First, try to use the PED-718 ESD Event Detector with Noise Filter switch turned off...
Page 5
L. Power PED-718 ESD Event Detector uses a 9V alkaline ba ery. Do not use any other type of ba ery. If you are not using your PED-718 ESD Event Detector for an extended period of me, remove the ba ery from the unit in order to prevent damage caused by ba ery leakage.
Page 6
PED-718 ESD Event Detector P. Antenna In order for the PED-718 ESD Event Detector to detect most ESD events, its antenna needs to be properly installed. Screw the antenna using only your fi ngers—no tools since over ghtening the connec on may lead to damage to the instrument.
Page 7
PED-718 ESD Event Detector Rev. A / April 2019...
Page 8
Specifi ca ons are subject to change without no ce. All Prostat trademarks and trade names are the property of Prostat Corpora on. All other trademarks and trade names are the property of their respec ve companies. P R O F E S S I O N A L...