o p e r at i n g i n s t r u c t i o n s m a n u a l
HYDRO-GUARD
HG-8
Warm Climate
Flushing
System
!
WARNING:
Platform weight is approximately 60 lbs. Use proper lifting tools and
techniques when loading and/or unloading device and lowering flushing
components into housing to avoid accidental drops and subsequent
damage to the device.
1. Each person involved in the assembly, installation and/or maintenance
of the Hydro-Guard Automatic Flushing Device must read this manual
carefully and follow all instructions prior to performing any installation or
maintenance procedures involving the Unit.
2. Verify the drainage path prior to installation to ensure that pedestrian
and vehicular hazards will not be created by the installation and use of the
Hydro-Guard Automatic Flushing Device (In areas in which freezing may
occur, special attention should be given to this procedure).
3. Never assemble, disassemble, or perform Hydro-Guard maintenance
unless the influent supply valve has been closed, verified and secured,
and internal piping pressure has been relieved.
4. Always use all necessary safety equipment and follow all recommended
procedures when installing, operating and maintaining the Hydro-Guard
Automatic Flushing Device.
5. Perform annual safety inspections and replace worn or defective parts.
6. Operate the Hydro-Guard Automatic Flushing Device only when fully
installed and correctly assembled.
!
cAutIoN:
The recommended optimal operating pressure for a Hydro-Guard
Automatic Flushing System is between 20psi and 120psi. In the event
pressure may exceed 120psi it is recommended that a Pressure Regulating
Valve be installed ahead of the Hydro-Guard flushing system.
®
www.muellercompany.com/hydro-guard
®
The content of this manual is the sole and exclusive property of Mueller Co.
Unauthorized distribution or reproduction strictly prohibited.

TAblE OF COnTEnTS

Assembly, Disassembly &
Maintenance Instructions
Reliable Connections
Customer Service Center
Decatur, Illinois
800.798.3131
moreinfo@muellercompany.com
PAGE
2-3
3-6
7
8
9
10
11
TM

Advertisement

loading
Need help?

Need help?

Do you have a question about the HYDRO-GUARD HG-8 and is the answer not in the manual?

Questions and answers

Summary of Contents for MUELLER CO. HYDRO-GUARD HG-8

  • Page 1: Table Of Contents

    o p e r at i n g i n s t r u c t i o n s m a n u a l HYDRO-GUARD ® HG-8 TAblE OF COnTEnTS PAGE Installation Instructions Warm Climate Programming Unit Assembly, Disassembly & Maintenance Instructions Flushing Troubleshooting...
  • Page 2: Installation Instructions

    hydro-guard hg-8 Warm Climate Flushing System ® Installation Instructions General overview Please read and retain this manual drainage pattern must permit for future reference, training, discharged water to flow away from The Hydro-Guard HG-8 Warm ® troubleshooting, and maintenance. the Hydro-Guard Unit.
  • Page 3 hydro-guard hg-8 Warm Climate Flushing System ® Installation Instructions & Programming unit InstallatIon – (continued) 4. Slowly lower the Hydro-Guard 8. We recommend installing 11. Disinfect the Hydro-Guard ® HG-8 Warm Climate Flushing approximately 10 ft. of pipe to the Automatic Flushing Device in System into place, pressing it firmly outlet connection so the plumber...
  • Page 4: Programming Unit

    hydro-guard hg-8 Warm Climate Flushing System ® Programming unit 6. All 4 numbers are shown with 2. Press + or – key to change station 4. To stop MANuAL FLuSHING two numbers on the left flashing, RuN tIME from 1 minute to 6 cycle press –...
  • Page 5 hydro-guard hg-8 Warm Climate Flushing System ® Programming unit LEFt and RIGHt ARRoWS – Programming Flushing Schedule HG-8 (requires Handheld) move curser left or right, also go There are two ways to proceed: tBoS-II Programming • select “tBoS-II infra-red” if IR back or forward one screen.
  • Page 6 hydro-guard hg-8 Warm Climate Flushing System ® Programming unit 7. Use LEFt ARRoW to navigate Stop Manual Flush Sequence 2. once data receipt is complete press RIGHt ARRoW to move to back to the program “Settings” 1. Reconnect IR cable to built-in menu.
  • Page 7 hydro-guard hg-8 Warm Climate Flushing System ® diassembly/reassembly Instructions HG-8 dIsassemBly and reassemBly InstructIons TOOLS NEEDED: Philips screwdriver, flat-head screwdriver, HG-20087 T-handle wrench the handheld to the antenna on the 7. Return valve plug to its proper Although the Hydro-Guard HG-8 ®...
  • Page 8: Troubleshooting

    hydro-guard hg-8 Warm Climate Flushing System ® Troubleshooting trouBlesHootInG tHe ProGrammer pRoBlEM caUsE solUtion Controller does not flush Water at main water supply is Check main supply valve as desired shut off Battery dead Replace battery Controller set to oFF Set controller to desired program Controller improperly programmed Check program and clock settings...
  • Page 9: Upgrades & Battery Replacement

    • Two-way real-time communication Management mode flush prior to the collection in via cellular, wifi, ethernet or order to ensure water indicative of The Hydro-Guard HG-8 can be BlueTooth ® the main-line water quality is being upgraded to include a S.M.A.R.T.
  • Page 10: Parts

    hydro-guard hg-8 Warm Climate Flushing System ® Parts rePlacement Parts DEscRiption Valve Box Curb Stop Valve Shut-off Installation Guide Male Camlock Camlock Release TB0S-11 Controller Interface Top Support Plate Support Frame Lower Support Dechlorination System Female Camlock 2” Double Check Valve Sample Quick Connect Support Riser...
  • Page 11: Notes

    hydro-guard hg-8 Warm Climate Flushing System ® Notes...
  • Page 12 Water (U.S.) International 1.800.423.1323 1.423.490.9555 www.muellercompany.com www.mueller-international.com Reliable Connections moreinfo@muellercompany.com international@muellercompany.com Copyright © 2017 Mueller Co., LLC. All Rights Reserved. The trademarks, logos and service marks displayed in this document herein are the property of Mueller Co., LLC, its affiliates or other third parties. Products marked with a section symbol ( §...