Mitsubishi Electric MSZ-BT20VG Operating Instructions Manual page 13

Split-type air conditioners
Hide thumbs Also See for MSZ-BT20VG:
Table of Contents

Advertisement

W
i-Fi INTERFACE SETTING UP (VGK type only)
This Wi-Fi interface, communicates the status information and controls
the commands from the MELCloud by connecting to the indoor unit.
Wi-Fi interface introduction
No.
Item
1
MODE switch
It selects modes.
2
RESET switch
It resets the system and ALL settings.
ERR LED (Orange)
It shows the network error state.
3
4
NET LED (Green)
It shows the network state.
5
MODE LED (Orange)
It shows the Access point mode state.
6
UNIT LED (Green)
It shows the indoor unit state.
3
4
5
ERR
NET
6
MODE
UNIT
RESET
MODE
2
1
(1) MODE switch
• The MODE switch is used for selecting modes in confi gurations.
(2) RESET switch
• Hold down the RESET switch for 2 seconds to reboot the system.
• Hold down the RESET switch for 14 seconds to initialize the Wi-Fi interface
to the factory default.
When the Wi-Fi interface is reset to the factory default, ALL the con-
fi guration information will be lost. Take great care in implementing this
operation.
Front panel
Wi-Fi interface
Front panel
Wi-Fi interface
Description
Wi-Fi
INTERFACE
MODEL
MAC-123IFB-E
MAC
: AABBCC112233
ID
: 1812280001
SSID
: ME-A123456789
KEY
: ABCDEF123456
VOLTAGE
: 12.7V
CURRENT
: 0.16A
MITSUBISHI ELECTRIC CORPRATION
WiFi.ASSY DWG No.
>PP<
DK00J098B01
MADE IN CHINA
JG79C123H01
1
Open the front panel and remove the Wi-Fi interface.
2
Set up a connection between the Wi-Fi interface and
the Router. Refer to the SETUP MANUAL and SETUP
QUICK REFERENCE GUIDE provided with the unit.
For SETUP MANUAL, please go to the website below.
http://www.melcloud.com/Support
3
Put the Wi-Fi interface back and close the front panel
after the setup is completed.
4
For MELCloud User Manual, please go to the website
below.
http://www.melcloud.com/Support
Note:
• Ensure that the Router supports the WPA2-AES encryption setting before
starting the Wi-Fi interface setup.
• The End user should read and accept the terms and conditions of the Wi-Fi
service before using this Wi-Fi interface.
• To complete connection of this Wi-Fi interface to the Wi-Fi service, the Rout-
er may be required.
• This Wi-Fi interface will not commence transmission of any operational data
from the system until the End user registers and accepts the terms and con-
ditions of the Wi-Fi service.
• This Wi-Fi interface should not be installed and connected to any Mitsubishi
Electric system which is to provide application critical cooling or heating.
• Please write down the information regarding the Wi-Fi interface setting on the
last page of this manual, when you set up this Wi-Fi interface.
• At the time of relocation or disposal, reset the Wi-Fi interface to the factory
default.
Mitsubishi Electric's Wi-Fi interface is designed for communication to
Mitsubishi Electric's MELCloud Wi-Fi service.
Third party Wi-Fi interfaces cannot be connected to MELCloud.
Mitsubishi Electric is not responsible for any (i) underperformance of a
system or any product;
(ii) system or product fault; or (iii) loss or damage to any system or product;
which is caused by or arises from connection to and/or use of any third
party Wi-Fi interface or any third party Wi-Fi service with Mitsubishi Electric
equipment.
For the latest information regarding MELCloud from Mitsubishi Electric
Corporation, please visit www.melcloud.com.