INTRODUCTION The Operation Manual contains guidelines and rules which refer to Eurosens fuel flow meters (hereinafter Flowmeter), developed by JSC Mechatronics, Vilejka, Belarus (mechatronics.by). The Manual is intended for specialists who are familiar with automobile repair, mounting and maintenance and possess professional knowledge in the field of electrical and electronic ...
RS232 and RS485 CAN – normalized pulse + CAN interface No symbol – without interface 2.3. Application Use of Eurosens flow meters: current fuel consumption records; registration of machinery working time; normalizing of fuel consumption limitations; fuel theft detection and prevention; real‐time monitoring and fuel consumption optimization; fuel consumption tests for engines. www.mechatronics.by Page 4 | 30 ...
(in this case differential flowmeter can measure up to 1000 liters/hour total fuel rate). Methods of settings are described in the service manual (see para.6). Recommendations for Eurosens Direct models selection depending on the power of the engine or boiler productivity. Table 3 Power of engine, KW(HP) Boiler productivity, KW Recommended models Direct XXX PN(PN I, P, RS) Less 100(136) Less 600 100 From 100(136) to 250(340) From 600 to 1200 250 From 250(340) to 600(816) From 1200 to 3500 500 WARNING! 1) It is not recommended to use the flow meter with the max. upper limit. www.mechatronics.by Page 5 | 30 ...
Page 7
‐ ± 1% Direct A 500 I 1,0 5 250 500 ‐ ± 1% Direct PN A 100 I 0,5 1 50 100 200 ± 1% Direct PN A 250 I 0,5 2 125 250 100 ± 1% Direct PN A 500 I 1,0 5 250 500 50 ± 1% A ‐ autonomous counter, built‐in battery power I‐ integrated LCD display www.mechatronics.by Page 7 | 30 ...
Page 8
Direct RS 100 0,5 1 50 100 200 ± 1% Direct RS 250 0,5 2 125 250 100 ± 1% Direct RS 500 1,0 5 250 500 50 ± 1% Direct CAN 100 0,5 1 50 100 200 ± 0,5% Direct CAN 250.05 0,5 2 125 250 100 ± 0,5% www.mechatronics.by Page 8 | 30 ...
Page 9
250 100 ± 1,2%** Delta CAN 500 I 1,0 40 250 500 50 ± 1,5%*** Flows to supply / consumption in liters / hour: * 45/10 ** 90/20 *** 160/30 I ‐ CAN LCD integrated display ‐ CAN interface RS ‐ RS232 / RS485 interface Eurosens flowmeters can also have a series of RS232 / RS485 data interfaces, as well as the CAN interface by RS232 / RS485 operation of the data interface protocol is possible Eurosens Delta or MODBUS. CAN interface is in accordance with the SAE J1939 specification. Table.6. Main specifications Parameter, measurement units Value Max pressure, MPa 2.5 Nominal pressure, MPa 0.2 Filtering degree of measured fluid, mm, not more 0.08 than Connection thread M14x1.5 M16x1.5 Pressure drop at maximum flow rate, nominal 0.02 pressure, diesel fuel at 20 °С, MPa, not more than Supply voltage range, V from 10 to 50 (from 9 to 32)* www.mechatronics.by Page 9 | 30 ...
ECE Regulations 10.04 Overall dimensions See para. 10 * for flow meters types Direct P (PH). ** Data is displayed in environment temperature range from ‐20 to +60 °C for flow meters with built‐in display. 2.7. Contents of package Table 7 № Position Quantity Flowmeter eurosens 1 Passport 1 Cable* 1 * Can be supplied separately. www.mechatronics.by Page 10 | 30 ...
Tampering The impact of где Y(max. flow constant Idle Normal Overload rate)= magnetic field operation l/hour for more than 10 seconds 100 < 2 2‐70 70‐100 > 100 Attempts are fixed 250 < 5 5‐200 200‐250 > 250 500 < 10 10‐400 400‐500 > 500 www.mechatronics.by Page 11 | 30 ...
Page 12
Cheat volume of supply chamber, l 12 Firmware version 12 Supply flow rate, l / h 13 Temperature in supply chamber, C 14 The total volume of return, l 15 Cheat volume of return chamber, l 16 Return flow rate, l / h 17 Temperature in return chamber, C 18 Battery charge, % 19 Firmware version * These parameters (plus some additional) are also displayed in configuration software on all flow meters PN (RS) (Eurosens Destination service kit is needed). ** for all models, aside Autonomous ***only for Autonomous modifications 2.8.4. Cheat protection features. In order to avoid cheating of flow sensor, its damage or blocking Delta and Direct PN, RS models has the following modes of protection against cheating actions of third parties: 1) Mode "Cheat" ‐ protection against cheating in order to increase the counter value of the consumed fuel (eg. air blowing). Cheat usually leads to a rapid increase in fuel consumption that exceeds the maximum one. Electronic circuit board of a flow sensor detects overstated costs, while fuel meter operation is stopped and counter "Cheat" is activated, which records the amount of fuel flown through the flow sensor at high speed. Mode "Cheat" is automatically exited in few seconds after the normalization of conditions of flow sensor work. www.mechatronics.by Page 12 | 30 ...
Page 13
2) Mode "Intervention" ‐ under the influence of an external magnetic field, the flow sensor detects an attempt to interfere and as the result the sensor itself is operating in standard mode and the exposure time is recorded in a special counter "Intervention time." Mode “Intervention” is automatically exited in few seconds after the end of attempts to interfere. 3) Sealing of connections ‐ mounting accessories (fuel connectors, clamps, etc.) supplied by JSC Mechatronics have holes for sealing, that allows to determine the facts of unauthorized interference in the fuel system after the installation of the flow sensor. 2.8.5. Characteristics of the pulse signal of Eurosens Flow meter with non‐standard pulse (model P) has an output pulse signal shown in Fig.2. For each flow meter the number of pulses generated by flowing of 1 liter of fuel through the measuring chamber is shown in the data sheet for the product (passport). ...
Page 14
* When the input load resistance (for example, the input of gps‐tracker is near 50 kiloohm) ** When the pull‐up output to power circuit (Ubat) is on for Direct PN. *** When the pull‐up output to power circuit is on (Ubat) for Delta PN. In the latest versions of sensors 0.8(Ubat – 0.8). www.mechatronics.by Page 14 | 30 ...
72 The actual information about the compatibility of particular models of gps‐tracker with Eurosens fuel flowmeters and also the recommendations on their connection and adjustment you can see on our web‐site – www.mechatronics.by WARRANTY 1) The manufacturer guarantees the compliance of Eurosens fuel flowmeters with the present technical requirements, provided that storage, transport and operation conditions are ...
To check the engine The engine should work regularly, The Customer eliminates operation for (5…10) minutes foes not fail (stall) the malfunctions under load or motion To check a system voltage by For the system voltage 12 V the The Customer eliminates voltmeter operating voltage should be in the the malfunctions range of 10 to 18 V. For the system voltage 24 V the operating voltage should be in the range of 10 to 32 V. When installing Delta fuel There shouldn’t be any air It is needed to install flowmeters ‐ to check if Deaerator or there is an air in return line The Customer eliminates the malfunctions To check the amount of fuel If the amount of fuel surpluses is To inform the Customer; surpluses, that are removed significant, the accuracy of if possible – to make www.mechatronics.by Page 16 | 30 ...
• Service kit Eurosens Destination • PC • mounting kit (sold separately); • Hand tools (wrenches, screwdrivers). The flow sensor can be mounted in any position: vertically, horizontally or inclined. Do not kink the cable and fuel pipes (fuel supply lines). It is recommended to mount the sensor www.mechatronics.by Page 17 | 30 ...
13. Do not use flowmeter with maximum flow rate lower than the actual one on the equipped vehicle or diesel generator. 14. It is not recommended to use internal or external filters with petrol gauze (the cell area is less than 0.6 microns) in the wiring scheme. There could be failures in work of fuel system at subzero temperatures. 4.4. Installation schemes of Eurosens fuel flow meters 4.4.1. Typical fuel supply system The most common scheme of the fuel system of diesel engine is shown on the Fig.4. www.mechatronics.by Page 18 | 30 ...
Page 19
EUROSENS Fuel flow meters. Operation manual. ver. 1.6 Fig.4. Typical fuel system Fuel backup pump (hereinafter – supply pump) supplies to the inlet of fuel injection pump (hereinafter ‐ fuel pump) significantly larger amount of fuel than is consumed in each cycle of operation of the engine. Excess fuel from the fuel pump and injectors of the engine is discharged back into the tank through relief valve. 4.4.2 Installation of fuel flow meters Eurosens Direct "On pressure side" scheme Installation of fuel flow sensor Eurosens Direct "On pressure side" scheme intends the installation of a flow sensor between fuel fine filter and fuel pump, where fuel is flown under pressure. Fig.5. Eurosens Direct installation «On pressure side». Check valve is necessary only for “Direct P, PH” series. www.mechatronics.by Page 19 | 30 ...
Page 20
Advantages of the scheme "on pressure side": • Eurosens Direct is set after the regular fuel fine filter; • Reduced flow resistance on the supply pump suction side. • Return flow heats fuel in the tank. Disadvantages of the scheme "on pressure side": • cooling of fuel pump decreases a little; • return line temperature is lower than in the standard fuel scheme. 4.4.3 Installation of Eurosens fuel flow meter under "suction scheme" Installation of fuel meter "on suction side" supposes the installation of a flow sensor in the area of the fuel system, where the fuel flow is forced by suction created by supply pump. WARNING! Installation of Eurosens Direct flow meter "on suction side" requires an additional fuel filter on the fuel line from the tank to the flow sensor. A special case of Direct flow meter installation under "suction scheme": To install the Direct under scheme "on suction" in the engine fuel system with fuel backup pump (see. Fig.6), it is necessary to use the site between the fuel pre‐filter and the inlet of fuel backup pump. www.mechatronics.by Page 20 | 30 ...
Page 21
To prevent measuring the volume of fuel returned to the fuel tank it is necessary to change the circuit return line. For this special case, it is necessary to change the fuel pump return line so that the fuel is circulated in a small circle without return to the fuel tank. This is done by connecting the return to the input of the fuel supply pump. Thus, to the inlet of supply pump two lines are connected: 1) supply from the tank, passing through the flow sensor; 2) The return fuel pump. Thus, through the flow sensor Direct goes only the amount of fuel which is consumed by the engine. WARNING! One of the advantages of fuel return to the tank through the fuel line is heating the rest of fuel in the tank. Therefore, if vehicles work at low temperatures it is recommended not to change the scheme of the fuel but to use differential flow sensor Delta, or install extra fuel heater. To install Eurosens Direct "on suction side" in the engine fuel system without the fuel supply pump (see. Fig.7), it is necessary to place the flow meter between the fuel pre‐filter and the fuel pump bypass valve. At the same time, an additional fine filter in the area between the place of installation of the flow sensor and the pre‐filter should be installed. www.mechatronics.by Page 21 | 30 ...
Page 22
Disadvantages of the scheme "under suction": additional fuel fine filter is needed, that increases the cost of installation; increased pressure on the fuel pump the fuel in the tank isn’t heated by the fuel from the return line (sometimes it is needed to install an additional heater) 4.4.4 Installation of Eurosens Delta under "Differential" scheme In differential scheme the measuring circuit of fuel circulating in the fuel system is not changed. Supply chamber of Delta sensor is installed in fuel supply line, return chamber – in return line. Fuel consumption is thus determined as the difference between the measured values of flows in the supply and return cambers. Particular cases of Delta installation under differential scheme: 1) The supply chamber is installed in the fuel line after supply pump and fine fuel filter (on pressure side). See Fig.8. 2) Supply chamber is installed in the fuel line before supply pump (on suction side). In this case, the installation of an additional fine filter is necessary (see. Fig.9). www.mechatronics.by Page 22 | 30 ...
Page 23
EUROSENS Fuel flow meters. Operation manual. ver. 1.6 Return chamber of Delta flow meter in both cases is installed in return line " high‐ pressure fuel pump inlet ‐ fuel tank." Fig.8. Eurosens Delta installation with supply chamber “on pressure side” Fig.9. Eurosens Delta installation with supply chamber “on suction side” Advantages of differential installation scheme: • No changes in the fuel system; • It can be mounted on the motors under warranty. Disadvantages of the "Differential" scheme: • higher cost; • Higher fuel consumption measurement error; www.mechatronics.by Page 23 | 30 ...
In case of malfunction of flow sensors Eurosens please contact your dealer. Eurosens sensors can be repaired only by certified service center or manufacturer. Initial diagnosis can be carried out by installer in accordance with Fig. 12‐13 (for Direct series) or with Fig. 14‐15 (for Delta series). For several steps the USB Destination 01 may be needed. www.mechatronics.by Page 24 | 30 ...
Page 25
EUROSENS Fuel flow meters. Operation manual. ver. 1.6 It is recommended to contact “Mechatronics” technical support or the nearest service center, all contact you can find on our web‐site: http://www.mechatronics.by/ Fig.12. Simple diagnostics of Eurosens Direct P(PH,PN) flow meters www.mechatronics.by Page 25 | 30 ...
Page 26
EUROSENS Fuel flow meters. Operation manual. ver. 1.6 Fig.13. Simple diagnostics of the Eurosens Direct P(PH,PN) flow meters (continuation) www.mechatronics.by Page 26 | 30 ...
Do not store Eurosens flow sensors in the same room with substances that cause corrosion of the metal and / or contain active agents. Storage life of eurosens flow sensors should not exceed 12 months. TRANSPORTATION It is recommended to transport Eurosens fuel flow sensors in closed transport that provides protection for sensors from mechanical damage and precipitation. Air environment in transportation compartments should not contain acid, alkaline and other aggressive impurities. www.mechatronics.by Page 28 | 30 ...
EUROSENS Fuel flow meters. Operation manual. ver. 1.6 Shipping containers with packed flow meters should be sealed. UTILIZATION/RECYCLING Eurosens fuel flow meters does not contain harmful substances and ingredients that are dangerous to human health and environment during and after the end of life and recycling. Eurosens fuel flow meters do not contain precious metals in amount that should be recorded. DIMENSIONS The sizes for different sensor models are shown below in Figures 16, 17. Fig.16. Dimensions of the EUROSENS Direct P (PH, PN, RS, CAN) www.mechatronics.by Page 29 | 30 ...
Page 30
EUROSENS Fuel flow meters. Operation manual. ver. 1.6 Fig.17. Dimensions of the EUROSENS Delta PN (RS, CAN) F – Forward (supply flow), R – Return/(return flow) www.mechatronics.by Page 30 | 30 ...