AN-84 describes a tool (TST-047) which enables test and debug of InnoSwitch3-Pro
based power supplies.
The TST-047 enables a set of operating conditions to be programmed into the
InnoSwitch3-Pro IC. Once programmed, these settings are stored in a Non-volatile
memory and are automatically transferred to the InnoSwitch3-Pro IC whenever the
power is cycled. This allows testing of the InnoSwitch3-Pro based power stage without
the need for an external Microcontroller.
This tool is especially helpful when repeated tests are to be performed such as EMI or
safety tests and the InnoSwitch3-Pro based power stage is to be set to a specific
operating point. This is useful when conducting thermal tests or tests where the unit is
being modified and there is a need for the InnoSwitch3-Pro to get configured with a
specific set of parameters after each power cycle.
PATENT INFORMATION
The products and applications illustrated herein (including transformer construction and circuits external to the products) may
be covered by one or more U.S. and foreign patents, or potentially by pending U.S. and foreign patent applications assigned
to Power Integrations. A complete list of Power Integrations' patents may be found at www.power.com. Power Integrations
grants its customers a license under certain patent rights as set forth at
property-licensing/.
TM
InnoSwitch
047) User's Guide
Applications Engineering Department
AN-84
June 26, 2019
1.1
Power Integrations
5245 Hellyer Avenue, San Jose, CA 95138 USA.
Tel: +1 408 414 9200 Fax: +1 408 414 9201
www.power.com
3-Pro Toggle Board (TST-
https://www.power.com/company/intellectual-

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the InnoSwitch 3-Pro Toggle Board and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Power integrations InnoSwitch 3-Pro Toggle Board

  • Page 1 U.S. and foreign patents, or potentially by pending U.S. and foreign patent applications assigned to Power Integrations. A complete list of Power Integrations' patents may be found at www.power.com. Power Integrations grants its customers a license under certain patent rights as set forth at https://www.power.com/company/intellectual-...
  • Page 2: Table Of Contents

    Use the last stored setting ................. 11 Operation ........................12 Start-up operation ....................12 Normal Operation ....................12 Bill of Materials ......................13 Revision History ......................14 Power Integrations Tel: +1 408 414 9200 Fax: +1 408 414 9201 Page 2 of 15 www.power.com...
  • Page 3: Introduction

    InnoSwitch3-Pro. It also contains the schematic, bill of materials, printed circuit board layout. Figure 1 – Top view of InnoSwitch3-Pro Toggle Board. Figure 2 – Bottom view of InnoSwitch3-Pro Toggle Board. Power Integrations Tel: +1 408 414 9200 Fax: +1 408 414 9201 Page 3 of 15 www.power.com...
  • Page 4: System Diagrams

    AN-84 InnoSwitch3-Pro Toggle Board (TST-047) User’s Guide 26-Jun-19 System Diagrams Schematic Diagram Figure 3 – Schematic. Power Integrations Tel: +1 408 414 9200 Fax: +1 408 414 9201 Page 4 of 15 www.power.com...
  • Page 5: Board Layout

    AN-84 InnoSwitch3-Pro Toggle Board (TST-047) User’s Guide 26-Jun-19 Board Layout Figure 4 – PCB Top Layout. Figure 5 – PCB Bottom Layout. Power Integrations Tel: +1 408 414 9200 Fax: +1 408 414 9201 Page 5 of 15 www.power.com...
  • Page 6: Hardware

    The board’s key features are indicated on the table below. Number Description Label Increment Switch Decrement Switch CC/CV/VKP Selection Switch PIC16F18326 PICkit3 Programming Header Connector to PSU RGB LED Indicator Power Integrations Tel: +1 408 414 9200 Fax: +1 408 414 9201 Page 6 of 15 www.power.com...
  • Page 7: Functional Description

    -200mV -1 LSB -200mV Adjustment Range Register Adjustment Range Default 3 ~ 20 V 25 ~ 128 LSB 5.3 ~ 24V Fixed 300mV Power Integrations Tel: +1 408 414 9200 Fax: +1 408 414 9201 Page 7 of 15 www.power.com...
  • Page 8: Slide Switch (Sw3 )

    Switch Register SW3A (V) SW3B (A) Configuration Selection Indicator No Change Configuration 1 Configuration 2 Green Configuration 3 Blue Configuration 4 Power Integrations Tel: +1 408 414 9200 Fax: +1 408 414 9201 Page 8 of 15 www.power.com...
  • Page 9: Led

    Not Used Power Ground reference for logic and I/O pins Not Connected Not Connected Positive Supply for Peripheral Logic and Power I/O Pins Power Integrations Tel: +1 408 414 9200 Fax: +1 408 414 9201 Page 9 of 15 www.power.com...
  • Page 10: Usage Instructions

    This will ensure that the saved configuration on the EEPROM will be used upon power cycle  Button press will be automatically disabled after 5 mins and LED will be Off Power Integrations Tel: +1 408 414 9200 Fax: +1 408 414 9201 Page 10 of 15...
  • Page 11: Use The Last Stored Setting

     Leave the Slide Switch configuration to either Configuration 1, 2, or 3.  Do not make any adjustments  EEPROM date will be uploaded to InnoSwitch3-Pro  After 5 mins LED will be Off Power Integrations Tel: +1 408 414 9200 Fax: +1 408 414 9201 Page 11 of 15 www.power.com...
  • Page 12: Operation

    Once the EEPROM data has been updated, at every power cycle, the button timeout of 5min will automatically start counting and buttons will be disabled thereafter. This provides an opportunity to make any setting changes. Power Integrations Tel: +1 408 414 9200 Fax: +1 408 414 9201 Page 12 of 15...
  • Page 13: Bill Of Materials

    AN-84 InnoSwitch3-Pro Toggle Board (TST-047) User’s Guide 26-Jun-19 Bill of Materials Complete list of the components used for the project. Power Integrations Tel: +1 408 414 9200 Fax: +1 408 414 9201 Page 13 of 15 www.power.com...
  • Page 14: Revision History

    * Added Summary Description * Updated Table Format 26-Jun-19 * Added Adjustment Range Table Apps & Mktg * Changed J2 Header to 6 Position (1x6) Power Integrations Tel: +1 408 414 9200 Fax: +1 408 414 9201 Page 14 of 15 www.power.com...
  • Page 15 The products and applications illustrated herein (including transformer construction and circuits’ external to the products) may be covered by one or more U.S. and foreign patents, or potentially by pending U.S. and foreign patent applications assigned to Power Integrations. A complete list of Power Integrations’...