Download Print this page
hager WXT30 Series Manual

hager WXT30 Series Manual

Advertisement

Available languages

Available languages

Quick Links

WXT30x
Gallery push-button, Tebis KNX bus,
xrockers, xinputs
WXT31x
Gallery push-button, Tebis KNX bus,
xrockers, xinputs with LED
WXT32x
Gallery push-button, Tebis KNX bus,
xrockers, xinputs with LED + 12 IR inputs
Number
Status
IR remote
of
LED +
receiver
push-
backlight
buttons
WXT302
2
WXT304
4
WXT306
6
WXT312
2
X
WXT314
4
X
WXT316
6
X
WXT322
2
X
X
WXT324
4
X
X
Safety instructions
Electrical equipment may only be installed and
assembled by a qualified electrician. Always
follow the relevant accident prevention
regulations of the country.
Failure to comply with these installation
instructions may result in damage to the
device, fire or other hazards.
When installing and laying cables, always
comply with the applicable regulations and
standards for SELV electrical circuits.
These instructions are an integral component
of the product and must be retained by the end
user.
1
Design and layout of the device
(2)
z
i
(1)
(2)
(2)
(1)
(3)
Figure 1: Front view of push-buttons 2, 4 and 6
rockers
(2)
(2)
(1)
(3)
(3)
(2)
(1)
(3)
Figure 2: Front view of push-buttons 2, 4 and 6
rockers with LED
(3)
(2)
Cover
(3)
WXE302x
WXE304x
Figure 3: Front view of push-buttons 2 and 4
rockers with LED and IR
WXE306x
(1)
Label holder cover
(2)
Push-buttons (number dependent on model)
WXE312x
(3)
Status LED
WXE314x
(4)
Sensor IR
WXE316x
Function
WXE312x
System information
(FPL IR)
This device is a product of KNX system and
WXE314x
complies with KNX guidelines. Detailed, specialised
(FPL IR)
knowledge obtained through specific KNX
training courses is required for full understanding
of the system. The planning, installation and
commissioning are to be carried out with KNX-
certified software or the Easylink configuration tool
(e.g. TXA100, version 1.5.0 or above).
Systemlink: Start-up
The functions of the device are software- and
configuration-dependent. You can find the latest
version of the application software as well as all
relevant technical descriptions on our website
(www.hager.com).
Easylink: Start-up
The functions of the device are software- and
configuration-dependent. It can also be configured
using devices specifically developed for easy set-
up and start-up.
This configuration method is only possible with
devices which are compatible with the Easylink
system. Preconfigured standard functions are
assigned to the in/outputs by means of the tool.
(2)
(2)
(1)
(1)
(2)
(2)
(2)
(2)
(1)
(1)
(3)
(3)
(2)
(2)
(2)
(1)
(2)
(1)
(3)
(3)
(3)
(3)
(2)
(1)
(2)
(1)
(3)
(3)
(3)
(1)
(1)
(2)
(4)
(4)
(3)
Correct use
- Typical applications: e.g. light ON/OFF, dim-
ming, blind UP/DOWN, saving and opening
light scenes, etc.
- Installation into flush mounting
(min. depth 40 mm)
- Installation into truncking
Product characteristics
- Start-up and programming in Systemlink and
Easylink mode
- Push-button functions: switching/dimming, varia-
tion, blind control, value transmitter, scene call-
up, specification of the heating operating mode,
forced control, stepping switch and comparator
function
- Integrated bus coupler
- Label holder
Specific characteristics of push-buttons with
LED and backlight
- One status LED per rocker
- The colour of the status LEDs is configurable
- Label holder with backlight
Specific characteristics of push-buttons with IR
receiver
- One status LED per rocker
- The colour of the status LEDs is configurable
- 12-channel IR remote receiver
- Label holder with backlight
Operation
Each rocker can be configured individually.
There are two, different, operating modes:
- Single-surface command:
Switching lighting on/off or dimming brighter/
darker is done alternately by repeated pressing of
the button.
- Two-surface command:
Two superimposed push-buttons form a function
pair. Pressing the top surface switches/dims
lighting on/makes it brighter; pressing the bottom
surface switches it off/makes it darker.
Use
Loads, such as lighting, blinds, etc., are operated
using the push-buttons, which are dependent on
the device programming.
G
The actuation pulse lasts for the duration of
the actuation. Depending on the function,
short and long actuations can trigger different
actions, e.g. switching/dimming.
IR functions
IR devices are fitted with a 12 channel IR receiver.
They can be controlled and operated via a Tebis
IR remote control or any IR remote compliant with
the RC6 standard. The buttons of the IR remote
control offer the same range of functions as with
the conventional local push-button functions.
6LE005164B

Advertisement

loading

Summary of Contents for hager WXT30 Series

  • Page 1 When installing and laying cables, always relevant technical descriptions on our website comply with the applicable regulations and standards for SELV electrical circuits. (www.hager.com). These instructions are an integral component of the product and must be retained by the end Easylink: Start-up user.
  • Page 2 KNX Medium TP 1 z Please refer to the detailed description of the Mounting Start-up mode Smode, Hager Easylink controller "Easylink" service module for more information Rated voltage KNX 30Vs SELV Proceed as follows on the configuration of the installation.
  • Page 3 12 kanalen die kunnen worden beschrijvingen zijn beschikbaar op onze kan schade aan het apparaat, brand of andere bediende via een tebis-IR afstandsbediening internetsite (www.hager.com). gevaren optreden. of elke IR-afstandsbediening die compatibel Bij installaties en kabelinstallaties de voor SELV- is met de RC6-standaard.
  • Page 4 Drukknop licht fysieke adressering mengd met ander bedrijfsaval voor verwijdering. Sierplaatje (niet meegeleverd) Bevestigingssteun (niet meegeleverd) Te gebruiken in geheel Europa M en in Zwitzerland Hager Controls S.A.S., 33 rue Saint-Nicolas, B.P. 10140, 67703 SAVERNE CEDEX, France - www.hager.com Hager 02.2018 - 6LE005164B...

This manual is also suitable for: