Download Print this page

Advertisement

Quick Links

OPTION 1 - PAGES 2 - 4
OPTION 2 - PAGES 5 - 7
Please read these instructions carefully and keep for future reference.
Incorrect fitting will invalidate the guarantee.
SAFETY
● Handle glass with care. Although the glass is very tough, sharp impacts can damage
both the glass and metal frame.
● Do not remove the plastic corner protectors from the glass panels until the panels
are about to be fitted.
● As the parts are large, we recommend that two people are needed to carry out parts
of the installation.
● Make sure there are no hidden pipes or cables in the floor and walls where you
intend to drill.
● Wear safety goggles, shoes and appropriate clothing.
BEFORE INSTALLATION
● The panel/s will not sit correctly on an uneven surface. If uneven, the wall
channels may not fit.
● Note: If not fitted on a tray, ensure panel/s are fitted to a tiled or waterproof
composite floor.
● The panel/s should be fitted on tiled walls which are sealed with waterproof grout.
● Always check very carefully that components are vertical.
EQUIPMENT NEEDED:
Drill, 4mm & 6mm Masonry Bits, Crosshead Screwdriver, Flatblade Screwdriver (small &
medium), Spirit Level, Pencil, Fine Tooth Saw, Silicone Sealant, Scissors, Masking Tape,
Tape Measure.
Note: The screws and wall plugs supplied are for masonry walls. For lightweight walls
i.e. stud partitions, plasterboard etc, use the correct type of fixings.
AQUA SCREEN PURE
OPTION 3 - PAGES 5 - 8
OPTION 4 - PAGES 9 - 13
Check contents of the pack before installation. If there is anything missing, contact our Technical Helpline Number for assistance.
The fixings may be spread across several packs - please check the contents of each pack carefully.
1
OPTIONS:
2
3
4
5
PN8203
5
5
10
5
2
32mm
Screw
PN8212
4
4
8
4
0
Washer
PN60210
5
5
10
5
2
Wall plug
PN40166
2
2
4
2
0
Seal
PN80506
0
1
2
0
0
Tie bar
bracket
PN80499
1
1
4
1
2
Tie bar
bracket
OPTION 5 - PAGES 14 - 17
TECHNICAL HELPLINE: 01460 258682
1
2
6
OPTIONS:
3
4
PN80500
Note: The *Spacer Plate PN80573 50
5
is only included with option 6.
*
1
1
2
1
Top
panel
4
bracket
PN80501
Note: The *Spacer Plate PN80583 is
only included with option 6.
*
5
0
0
0
1
Shower
panel foot
2
*PN10785
Note: The quantities of the threshold
strips will depend on size of panels.
Aluminium
*Optional Extras, not included in pack.
threshold
strip
1
1
1
2
1/2
OR
PN40177
1
Plastic
threshold
strip
71399 00 / Issue 11 / 16
OPTION 6 - PAGES 18 - 20
6
1
5
OPTIONS:
2
3
4
PN4745
1
1
2
1/2
2
*1
Screw
cover cap
PN50247
1
1
2
1
2
*1
Top cap
PN50266
0
0
0
1
Corner
joint cap
PN60162
1/2
0
1/1
1/1
1/1
1/1
2 & 3mm
Allen keys
5
6
2/4
1/2
0
1
2
0
1/1
1/1
PAGE 1

Advertisement

loading

Summary of Contents for impey AQUA SCREEN PURE

  • Page 1 71399 00 / Issue 11 / 16 AQUA SCREEN PURE OPTION 1 - PAGES 2 - 4 OPTION 2 - PAGES 5 - 7 OPTION 3 - PAGES 5 - 8 OPTION 4 - PAGES 9 - 13 OPTION 5 - PAGES 14 - 17 OPTION 6 - PAGES 18 - 20 Please read these instructions carefully and keep for future reference.
  • Page 2 OPTION 1 - SINGLE PANEL WITH STRAIGHT TIE BAR IMPORTANT Ensure Glass Guard H2o label is to the outside of the panel. Tie bar Satin glass patterns PN10786 MUST be installed to the outside of the ø 6 panel. Note: The Glass Guard coating is on the opposite side to the label or satin glass...
  • Page 3 Option 2 - Fitting threshold strips inside the wall channel Sealant = Height of threshold strip Remove the panel from the wall channel. A: Aluminium threshold strip - Position the strip inside the wall channel. Run a bead of silicone sealant down the length of the threshold strip. Angle the panel and carefully push (the correct way around) into the wall channel and threshold strip.
  • Page 4 ø 6 PN80499 Inside Remove the tie bar assembly from the panel. partitions, plasterboard etc, use the correct type of fixings. Push fit the top cap onto the top of the wall channel. e: Screw the tie bar bracket back onto the wall bracket. a: Unscrew the wall bracket from the end of the tie bar bracket.
  • Page 5 OPTION 2 - SINGLE PANEL WITH ANGLED TIE BAR Tie bar IMPORTANT PN10786 Ensure Glass Guard H2o label is to the outside of the panel. Satin glass patterns MUST be installed to the outside of the ø 6 panel. Note: The Glass Guard coating is on the opposite side to the label or satin glass...
  • Page 6 Option 2 - Fitting threshold strips inside the wall channel Sealant = Height of threshold strip Remove the panel from the wall channel. A: Aluminium threshold strip - Position the strip inside the wall channel. Run a bead of silicone sealant down the length of the threshold strip. Angle the panel and carefully push (the correct way around) into the wall channel and threshold strip.
  • Page 7 ø 6 PN80499 Inside Remove the tie bar assembly from the panel. stud partitions, plasterboard etc, use the correct type of fixings. Tighten the large screws on both of the tie bar brackets. e: Screw the tie bar bracket back onto the wall bracket. a: Unscrew the wall bracket from the end of the tie bar bracket.
  • Page 8 OPTION 3 - DOUBLE PANEL WITH ANGLED TIE BARS To fit the Tie bars PN10786 DOUBLE PANEL Wall WITH ANGLED TIE BARS option, follow the same steps as the SINGLE PANEL WITH ANGLED PANEL PANEL Tie bar. Opening Plan position of panels. The size of the opening will depend on the tray (if used) or the site conditions.
  • Page 9 OPTION 4 - SINGLE PANEL WITH RETURN PANEL Tie bar PN10786 IMPORTANT Ensure Glass Guard H2o label is to the outside of the panel. Satin glass patterns MUST be installed to the outside of the ø 6 panel. Note: The Glass Guard coating is on the opposite side to the label or satin glass...
  • Page 10 Option 2 - Fitting threshold strips inside the wall channel Sealant = Height of threshold strip Remove the panel from the wall channel. A: Aluminium threshold strip - Position the strip inside the wall channel. Run a bead of silicone sealant down the length of the threshold strip. Angle the panel and carefully push (the correct way around) into the wall channel and threshold strip.
  • Page 11 ø 6 PN80499 Inside Remove the tie bar assembly from the panel. partitions, plasterboard etc, use the correct type of fixings. Push fit the top cap onto the top of the wall channel. e: Screw the tie bar bracket back onto the wall bracket. a: Unscrew the wall bracket from the end of the tie bar bracket.
  • Page 12 Option B - Return panel with threshold strips RETURN PANEL (outside) MAIN RETURN RETURN PANEL PANEL PANEL (outside) (outside) (outside) a: Temporarily, position the return panel into the ‘long side*’ of the corner joint. c: Carefully measure the length of return panel protruding out of the corner e: Apply silicone sealant down the inside of the ‘long and short sides’...
  • Page 13 Options C & D - continued Sealant ø 4 MAIN PANEL (outside) Option a: Drilling floor for foot - Use the dimensions above to mark and drill the ‘pin’ hole in the floor. c: Apply silicone sealant down the inside of the ‘long and short sides’ of the A: Aluminium threshold strip - Position the strip up against the corner joint.
  • Page 14 OPTION 5 - SINGLE PANEL WITH 2 RETURN PANELS Optional threshold strips Tie bars PN10786 Wall 1180mm Aluminium max. 1180mm max. Inner face of main panel Plastic Plan the position of the main panel, the maximum distance the Corner joint main panel can be from the wall is 1180mm.
  • Page 15: Fitting Options

    ø 6 PN80499 Approx. 100mm Approx. 100mm PN80499 Inside Remove the tie bar assemblies from the panel. For lightweight walls i.e. stud partitions, plasterboard etc, use the correct type of fixings. a: Unscrew the wall brackets from the end of the tie bar brackets. e: Screw the tie bar brackets back onto the wall brackets.
  • Page 16 Option B - Return panels with threshold strips RETURN PANEL (outside) MAIN RETURN RETURN PANEL PANEL PANEL (outside) (outside) (outside) a: Temporarily, position the return panels into the ‘long side*’ of the corner joints. c: Carefully measure the length of return panel protruding out of the corner e: Apply silicone sealant down the inside of the ‘long and short sides’...
  • Page 17 Options C & D - continued Sealant ø 4 MAIN PANEL (outside) Option a: Drilling floor for feet - Use the dimensions above to mark and drill the ‘pin’ holes in the c: Apply silicone sealant down the inside of the ‘long and short sides’ of the A: Aluminium threshold strip - Position the strip up against the corner joints.
  • Page 18 OPTION 6 - SINGLE CURVED PANEL WITH TIE BAR IMPORTANT Ensure Glass Guard H2o label is to the Tie bar outside of the panel. PN10786 Satin glass patterns MUST be installed to the outside of the ø 6 panel. Note: The Glass Guard coating is on the opposite side to the label or satin glass...
  • Page 19 ø 6 PN80499 PN80573 50 Inside Remove the tie bar assembly from the panel. partitions, plasterboard etc, use the correct type of fixings. Push fit the top cap onto the top of the wall channel. e: Screw the tie bar bracket back onto the wall bracket. a: Unscrew the wall bracket from the end of the tie bar bracket.
  • Page 20: Care And Maintenance

    End of life:- This product contains materials such as aluminium and glass which can be recycled. Please contact your local authority to find your nearest recycling centre. IMPEY SHOWERS LTD Conquest Business Park, Ilton, Somerset, TA19 9EA info@impeyshowers.com Tel: 01460 256080 • Fax: 01460 259800...