  • Page 2 HOT FLUID. DO NOT FILL BEYOND MAXIMUM FILL LINE LOCATED IN THE FRYER VESSEL. 9902091 9902091...
  • Page 3: Table Of Contents

    PORTABLE FILTER  TABLE OF CONTENTS INTRODUCTION .............. 1 DISASSEMBLY ............6 - 7 Melt/Pump Indicator Lights ........... 6 Damage During Shipment ..........1 OPERATING INSTRUCTIONS ..........1 Melt/Pump On/Off Switch ..........6 Preparing the Portable Filter ..........2 Melt Cycle Sensor ............7 Filtration .................
  • Page 4: Preparing The Portable Filter

    PREPARING THE PORTABLE FILTER Figure 1-3 Assemble fi lter 1. Remove screen from over tubes/element with tongs or a Drain Clean Out Rod (See Figure 1-1). STRAINER BASKET DRAIN CLEAN OUT ROD HOLD DOWN RING Figure 1-1 Remove screen over FILTER PAPER elements/tubes FILTER SCREEN...
  • Page 5: Clean-Up

    PORTABLE FILTER 4. Direct end of fi lter wand into fryer vessel and then Figure 2-4 place fi lter MELT/OFF/FILTER toggle switch to FILTER Fill fryer with fi ltered oil position. If oil does not fl ow through wand and into WAND fryer vessel, position toggle switch to MELT position for ten minutes to melt any oil in fi...
  • Page 6: Filter Failure

    In the event that your fi lter, under warranty, needs repairs other than routine cleaning, you are requested to contact KEATING OF CHICAGO, INC. (1-800-KEATING) before calling a local service company. HOT FLUID. DO NOT FILL BEYOND MAXIMUM FILL LINE LOCATED IN THE FRYER VESSEL.
  • Page 7: Service Diagnosis

    PORTABLE FILTER  SERVICE DIAGNOSIS The following diagnosis is only to be used as a guide to qualifi ed service personnel. Keating recommends that you use a qualifi ed & licensed service company. (Equipment still under warranty requires it.) NOTE: To correctly and quickly diagnose the system, the chart below should be followed in sequential order. TROUBLE SHOOTING CHART PROBLEM PROBABLE CAUSE...
  • Page 8: Preventative Maintenance

      PREVENTATIVE MAINTENANCE SERVICE Preventative maintenance should be performed during DISASSEMBLY & after each use of the fi lter. Following preventative maintenance procedures will help to keep your fi lter You will need: working effi ciently. Proper care & servicing will lead to Adjustable wrench "Stubby"...
  • Page 9: Melt Cycle Sensor

    PORTABLE FILTER 2. Insert replacement switch through panel from 4. Remove electrical leads from defective heater which defective switch was removed. Insert name- element(s). Tag leads as they are disconnected to as- plate over toggle and secure to panel with nut sup- sure, during replacement, they are reconnected to the plied with switch.
  • Page 10: Heat Tape

    Replacement: 1. Install removed plumbing parts into replacement pump and motor suction port in same orientation noted at removal using tefl on tape or a good food grade pipe joint compound on male threads only of disassembled plumbing parts. 2. Position pump and motor onto its base and secure loosely with removed screws, fl...
  • Page 11: Service Parts Ordering

    HOLD DOWN RING LB100 000576 HOLD DOWN RING LB100 (after 1/2003) 054803 HOSE, 4' w/fi ttings & Stiffner Spring for SUPPLIES PC14 (for LB Filters prior to 2/3/93) 000569 DESCRIPTION HOSE, 5' w/fi ttings for LB Filters after 2/3/93) 018157...
  • Page 12 HOSE, 4' with nozzle & fi ttings 017640 INDICATING LIGHT, Red 000525 INSULATION BOARD 007694 PUMP/MOTOR 008196 SCREEN 005871 SPRING for 'T' HANDLE 006656 PC14 STRAINER BASKET PC14 012054 SWITCH (Pump/Off/Melt) 000521 TERMINAL BOARD 000639 TERMINAL BOARD INSULATION 000263 keatingofchicago.com...
  • Page 13: Wiring Diagrams

    PORTABLE FILTER  WIRING DIAGRAM LB100, LB165, LB200 1 WAY PUMP - PUMP PART # 008196 LB100, LB165 & LB200 2 WAY PUMP - PUMP PART # 055173 (1988-2002) 1-800-KEATING...
  • Page 14  WIRING DIAGRAM LB165 & LB200 1 WAY PUMP (2004 Series) - PUMP PART # 055173 LB165 & LB200 1 WAY PUMP (After 2005) - PUMP PART # 055173 keatingofchicago.com...
  • Page 15 PORTABLE FILTER  WIRING DIAGRAM LB165 & LB200 1 WAY PUMP (2003 Series) - PUMP PART # 052982 LB165 & LB200 2 WAY PUMP (After 2004) - PUMP PART # 055173 1-800-KEATING...
  • Page 16  WIRING DIAGRAM LB200 1 WAY PUMP - PUMP PART # 010567 (1993) LB200 2 WAY PUMP - PUMP PART # 010567 (1993) keatingofchicago.com...
  • Page 17 PORTABLE FILTER  WIRING DIAGRAM PC 14 1-800-KEATING...
  • Page 19 CUSTOM PASTA FILTER SYSTEM TOP-SIDE COOKER HOTPLATE I HAVE READ THE INSTALLATION AND OPERATING INSTRUCTIONS. SIGNED: DATE: KEATING OF CHICAGO, INC. 1-800-KEATING 8901 West 50th Street PHONE: 708-246-3000 McCook, IL 60525-6001 FAX: 708-246-3100 Serving Those Who Serve the Very Best...

This manual is also suitable for:

Lb100Lb165Lb200

Table of Contents