XPR Access EWS-DR Installer Manual

2 doors/2 readers access control unit

Advertisement

Quick Links

EWS-DR/ EWSi-DR
Fingerprint
reader
Violet
Pink
Door Sensor
(NC, mechanical or
relay dry contact)
Card reader
5 - 30V
Power
-
+
Supply
Power supply
12V
Communication
COM
TCP
Ethernet
UDP
SPECIFICATIONS
Power Supply:
User/Event capacity:
Communica on:
Door relays:
Programmable Outputs:
Readers:
Programmable Inputs:
Door sensors:
Exit Bu on Inputs:
Wiegand interface:
Environment temperature:
Humidity:
Consump on:
Fuse protec on:
2 Doors/2 Readers Access Control Unit
INSTALLER MANUAL
Exit Button
(NO, mechanical or
relay dry contact)
DS2
GND
PB2
Green
LED1
Orange
LED2
Black
GND
Red
12V
D0
White
D1
Yellow
DS1
GND
PB1
Green
LED1
Orange
LED2
GND
Black
12V
Red
D0
White
D1
Yellow
T
GND
12V out
IN1+
-
IN1-
IN2+
+
IN2-
-
GND
-
GND
12V
EARTH- fixing holes for
earth connection
TX
RX
SYS1
SYS2
D1
D2
O1
O2
DOOR 1/2 OUTPUT 1/2
12VDC
1000/30000, 4000/24000, 8000/16000, 12000/8000 or 15000/2500, configurable by so ware
EWS-DR -RS485, EWSi-DR -RS485 and TCP/IP
2 (250 VAC, 10A)
2 (250 VAC, 10A)
2
2, optocoupled, ON level 5-30VDC (3-28mA)
2
2
Programmable (8 to 128bit), 32databits, 4 parity bits
0 - 45 C
0-80 %, non condensing
EWS-DR 200mA, EWSi-DR 250mA (without readers)
1A thermal fuse for total consump on of the controller and readers.
Battery
(CR2032)
DOOR SENS
+
& EGRESS 2
NC4
COM
OUTPUT 2
NO4
NC3
COM
OUTPUT 1
NO3
READER 2
NC2
DOOR SENS
DOOR 2
COM
& EGRESS 1
NO2
NC1
DOOR 1
COM
NO1
READER 1
T2
T1
Com
I/O
B
TAMPER
COM
A
IP
Reset
Com
INPUT 1
RS485
B
INPUT 2
A
TCP
netw
POWER
TCP/IP
ork
12 VDC
Default IP: 192.168.1.100
port: 4001
Transmit/Receive
SYSTEM OK (Heartbeat)
EN
Lock
Power
Supply
-
+
Electric Door Strike
(AC powered)
C
R 10K
AC
Electric Door Strike
(DC powered)
-
+
DC
Electro Magnetic Lock
-
+
For I/O0408
relay board
Reset IP
(press and hold for 3sec
to reset the IP, the port
and the network password)
Schematic of the EWS-DR
input optocoupler
EWS-DR
1k
IN1+
IN1-
IN2+
IN2-
GND
DIPSWITCH
pin1:for termination
of the RS485 cable
on the terminal
block pins A and B
pin2:for termination
of the I/O COM port
on the terminal block
pins
62mm
1

Advertisement

loading

Summary of Contents for XPR Access EWS-DR

  • Page 1 DOOR 1/2 OUTPUT 1/2 SPECIFICATIONS Power Supply: 12VDC User/Event capacity: 1000/30000, 4000/24000, 8000/16000, 12000/8000 or 15000/2500, configurable by so ware Communica on: EWS-DR -RS485, EWSi-DR -RS485 and TCP/IP Door relays: 2 (250 VAC, 10A) Programmable Outputs: 2 (250 VAC, 10A) Readers: Programmable Inputs:...
  • Page 2 - Connect the COM to each unit in the RS 485 line. - Terminate both ends of the line with 120 Ohm resistor. If end of line is EWS-DR, use built in resistor (120 ohm) by turning the Dipswitch pin1 ON.
  • Page 3 IP: Portal IP address. Setup Port: Used for searching the portals of the network. Password: For searching and configuring the portals. Mask: IP Mask. Gateway: Network Gateway. MAC: Mac portal. DHCP enable: It is recommended that DHCP is disabled and fixed IP value is used. DNS: Domain name server.
  • Page 4 -Make sure there is no other so ware communica ng with the controllers. -Check with the WEB interface of the EWS-DR if the se ngs are correct. 6. Searching portals in so ware shows only some or none of the portals.

This manual is also suitable for:

Ewsi-dr