Do you have a question about the ST1050 and is the answer not in the manual?
Questions and answers
Summary of Contents for PARRY ST1050
Page 1
DATE 19.07.11 Page 1 of 59 GUIDELINE FOR THE SELECTION, INSTALLATION, AND OPERATION OF PARRY EXTRACTION CANOPIES MODELS: SNACK TYPE CANOPY RANGE GENERAL TYPE CANOPY RANGE TITAN TYPE CANOPY RANGE Parry Group Limited, Town End Road, Draycott, Derby, England DE72 www.parry.co.uk...
Page 2
Canopy drawings showing aperture cut out for fitting internal fans and ducting Speed controllers Speed controller installation instructions Canopy Lights Types of available lighting Canopy light fitting instructions Parry Group Limited, Town End Road, Draycott, Derby, England DE72 www.parry.co.uk...
Page 3
Page 3 of 59 Gas Interlock Gas interlock system Interlock controller Pressure switch Gas Solenoid valve and pressure transducer Speed controller installation instructions Warranty information Disposal information Parry Group Limited, Town End Road, Draycott, Derby, England DE72 www.parry.co.uk...
Page 4
Canopy specifications Snack Type Range, General Type Range and Titan Type Range Parry canopies are designed for small and medium size commercial kitchens. With three different ranges of canopy on offer there are plenty of styles and sizes to choose from.
Page 5
43Kg TT1575 1500 x 1200 x 750 52Kg TT1875 1800 x 1200 x 750 72Kg TT2175 2100 x 1200 x 750 81Kg TT2475 2400 x 1200 x 750 91Kg Parry Group Limited, Town End Road, Draycott, Derby, England DE72 www.parry.co.uk...
Page 6
This can be done to achieve a special length of canopy, or because access to site is limited. Parry offer it's customers the opportunity to do this by providing cut outs to the side panels of the canopy, and fixing holes to allow one canopy to be bolted to another.
Page 7
Health and safety regulations will also have reference to ensuring that an area that contains catering equipment has sufficient ventilation and air circulation. Parry Group Limited, Town End Road, Draycott, Derby, England DE72 www.parry.co.uk...
Page 8
Typical Canopy Dimension diagram, taken from DW/172 Specification for Kitchen Ventilation. Canopy code Maximum depth of unit that can be positions underneath it. Snack Type 560mm General Type 750mm Titan Type 950mm Parry Group Limited, Town End Road, Draycott, Derby, England DE72 www.parry.co.uk...
Page 9
Safety instructions for fitting a canopy IMPORTANT, PLEASE READ INSTRUCTIONS FULLY BEFORE USE Parry canopies have been designed to be fitted in a kitchen over an appliance, as part of an extraction solution. Please note that it is the responsibility of the...
Page 10
Parry offer a range of sizes of canopies. If a customer requires a canopy that is longer than 2400mm, several canopies can be joined together. Baffle filters and fixing bolts to attach the canopies together are supplied with the unit.
Page 11
In the longer lengths two fans maybe required and these are spread equally a third of the way along the canopy length. Canopies with two fans require two sets of ducting, or a non return valve. Parry Group Limited, Town End Road, Draycott, Derby, England DE72 www.parry.co.uk...
Page 12
Please ensure that all the bolts are securely tightened before hanging the canopy on the wall. An earth tag has been provided and we would recommend that all units are earthed. Parry Group Limited, Town End Road, Draycott, Derby, England DE72 www.parry.co.uk...
Page 13
External fan Parry offer all of their canopies with the option of an external fan packs. These are especially useful for difficult applications, long runs, and runs with a change in direction.
Page 14
To help the liquid flow into the drain or tray, it is best to fix the unit at a slight angle. Parry Group Limited, Town End Road, Draycott, Derby, England DE72 www.parry.co.uk...
Page 15
Care should be taken when removing filters as generally the unit will be mounted high up on a wall over catering appliances. All Parry canopies are fitted with a drip tray. The drip tray is easily removable and must be emptied regularly.
Page 16
The Snack type canopy range use the 400mm filter and the General and Titan type use the 500mm. Parry also supply as a spare 430 x 430 mm mesh filters, to anyone who has an old mesh filter canopy. Filters must be washed regularly and drip trays mounted under the unit should be emptied and the Canopy wiped down.
Page 18
DATE 19.07.11 Page 18 of 59 Duct Mounted Fans Parry sell duct mounted fans as part of the Canopy Value Pack. Features of the duct mount short cased axial fans: • Sickle & aerofoil bladed fans, 315mm to 500mm • Fan - single phase, 230V - 1Ph - 50Hz •...
Page 19
ØF G kg 382 317 9.5 356 135 8 466 400 9.5 438 155 12 10.3 515 415 9.5 487 160 12 15.8 567 503 9.5 541 165 12 16.6 Parry Group Limited, Town End Road, Draycott, Derby, England DE72 www.parry.co.uk...
Page 20
Wiring diagram For the following models: ZSC315-41 / ZSC400-41 / ZSC450-41 / ZSC500-41 Wiring Colours U1 = brown U2 = blue Z1 = black Z2 = orange TB = white Parry Group Limited, Town End Road, Draycott, Derby, England DE72 www.parry.co.uk...
Page 21
INSTRUCTION REF: IN208 ISSUE No. DATE 19.07.11 Page 21 of 59 Parry Canopy Specification for Duct Mounted Fans Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
Page 22
H – Minimum distance from edge to hole centre. I – Minimum distance from edge to hole centre. Back Elevation Side Elevation Top Elevation Canopy Range Snack Type General Type Titan Type Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
Page 23
2D POD is two fan diameters long with a centre pod All noise levels are measured at a distance of 3 metres Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
Page 24
SERVICE (44) 01332 875665 FAX: SERVICE (44) 01332 875536 Internal Direct Drive Centrifugal Fans Parry offer a new range of canopies with internal fans. The internal fans used are centrifugal type fans. Unless otherwise stated on an order, all canopies sold with internally mounted fans will have the fan extracting through the top panel.
Page 25
INSTRUCTION REF: IN176 ISSUE No. DATE 2.01.08 Page 25 of 59 TELEPHONE: SERVICE (44) 01332 875665 FAX: SERVICE (44) 01332 875536 Internal Fans Sizes DD-7-7 DD-9-9 Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
Page 26
INSTRUCTION REF: IN176 ISSUE No. DATE 2.01.08 Page 26 of 59 TELEPHONE: SERVICE (44) 01332 875665 FAX: SERVICE (44) 01332 875536 Parry Canopy Specification for Internal Centrifugal Fans Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
Page 27
INSTRUCTION REF: IN176 ISSUE No. DATE 2.01.08 Page 27 of 59 TELEPHONE: SERVICE (44) 01332 875665 FAX: SERVICE (44) 01332 875536 Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
Page 28
INSTRUCTION REF: IN176 ISSUE No. DATE 2.01.08 Page 28 of 59 TELEPHONE: SERVICE (44) 01332 875665 FAX: SERVICE (44) 01332 875536 Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
Page 29
INSTRUCTION REF: IN176 ISSUE No. DATE 2.01.08 Page 29 of 59 TELEPHONE: SERVICE (44) 01332 875665 FAX: SERVICE (44) 01332 875536 Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
Page 30
INSTRUCTION REF: IN176 ISSUE No. DATE 2.01.08 Page 30 of 59 TELEPHONE: SERVICE (44) 01332 875665 FAX: SERVICE (44) 01332 875536 Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
Page 31
INSTRUCTION REF: IN176 ISSUE No. DATE 2.01.08 Page 31 of 59 TELEPHONE: SERVICE (44) 01332 875665 FAX: SERVICE (44) 01332 875536 Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
Page 32
INSTRUCTION REF: IN176 ISSUE No. DATE 2.01.08 Page 32 of 59 TELEPHONE: SERVICE (44) 01332 875665 FAX: SERVICE (44) 01332 875536 Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
(M1N). It is the responsibility of the user to ensure compliance with the Health & Safety at Work Act, 1974. 2. Ensure that the motor is suitable for speed control with a triac device. Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
Page 34
It is the EMC conformance of the final system which counts in law. All products carry a two year guarantee when correctly connected to suitably specified fan motors. Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
Page 35
(filly anti-clockwise) then open the lid to access the potentiometer (MIN). Adjust as required. Beware of setting too low a value which could cause a stall condition on the fan. Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
Page 36
40 degrees C ambient on single phase 220/240v 50Hz supply. 2. The normal equipment operating range is 0 degrees C to 40 degrees C ambient. 3. Component temperature range is -20 degrees C to +60 degrees C. Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
Page 37
It is the EMC conformance of the final system which counts in law. All products carry a two year guarantee when correctly connected to suitable specified fan motors. Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
ISSUE No. DATE 2.01.08 Page 38 of 59 TELEPHONE: SERVICE (44) 01332 875665 FAX: SERVICE (44) 01332 875536 PCB LAYOUT WIRING THE MOTOR Motor wiring is shown below Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
Make the connections to the control as follows: Terminal No: 1. Supply Earth 2. Supply Live (L) 3. Supply Neutral (N) 4. Motor Neutral (NI) 5. Do not use 6. Motor Control Live (L1) Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
8. Maximum Speed - The maximum speed is preset to full speed. If it is necessary to adjust then first ensure the control knob is set to maximum, and remove the front panel to access the potentiometer. Adjust as required. Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
Page 41
FAX: SERVICE (44) 01332 875536 Canopy Lights Types of available lighting Lighting solutions can be sold to fit in the Parry ranges of canopies. Inset or Surface Mount Light Boxes Stainless steel construction Obscured toughened glass One 13amp plug ...
Page 42
Note: to maintain IP rating and weather proofing, fitting a suitable gasket (rubber) should be used when mounting on a BESA Conduit box – fitted by M4 screws through holes provided on rear of fitting. Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
Page 43
60second period. Low pressure indicates a leak and the interlock system cuts the gas supply. Parry are now offering canopies sold complete with gas interlock systems. For use with canopies with internal centrifugal fans.
Page 44
• Can be used on Natural and LP Gas • LED status indications. • Must be used with an ENI6I Approved solenoid or Electro-Hydraulic safety shut off valve. • Connections to gas supply safety shut-off valve. Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
1 x 90° fitting (R 1⁄4 male elbow x 8 mm nut/olive) 1 x straight fitting (R 1⁄4 male x 8 mm nut/olive) 2 x large cable glands (M16) 1 x small cable glands (PG7) Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
Page 46
Prior to drilling the PCB must be removed. Once the holes have been drilled they must be carefully deburred and all plastic shavings removed from the enclosure. Replace the PCB using the two screws. Do not over tighten these screws. Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
Page 47
ON position. Safety Installation must be by a qualified electrician and must meet all local regulations. The mains supply should be externally fused at 3 amps. Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
Page 48
In the installed condition the respective device-specific requirements on the type of protection must be fulfilled. – Do not change adjustment of factory-adjusted and paint-sealed switches (screw B and C). Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
Page 49
– Adjust upper and lower switching points with the dial (B). – In case of vacuum: connect P2 Adjustments as indicated in the instructions, except pressure = vacuum. – Fasten bracket to switch with original factory-supplied screws only. Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
Page 50
INSTRUCTION REF: IN176 ISSUE No. DATE 2.01.08 Page 50 of 59 TELEPHONE: SERVICE (44) 01332 875665 FAX: SERVICE (44) 01332 875536 Fig. 3 Recommended installation arrangement vertical (factory calibration). Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
Page 51
Adjust switch within printed-on scale only! Do not turn the dial (B) into the area of the black mark ! [Switching contact changes from NC (1-2) to NO (1-2).1 Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
Page 52
INSTRUCTION REF: IN176 ISSUE No. DATE 2.01.08 Page 52 of 59 TELEPHONE: SERVICE (44) 01332 875665 FAX: SERVICE (44) 01332 875536 Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
Page 53
Interlock controller. This will instigate a further pressure check, and if all is found to be satisfactory, restore electrical power to the gas solenoid, which will open the valve. Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
Page 54
Complies with low voltage directive 72/23/CEE Complies with EMC directives 89/336CEE and MODS All models fitted with motor protection fuse Spare fuse included with each controller Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
Page 55
15.00 87 x 147 x 11** 0.55 IP44 1Ph 50Hz * + 47mm metal backing box ** +15mm for knob (3SS = 35mm) for flush mounting Wiring Diagram Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
• Please ensure you have read the section not covered under warranty to avoid unnecessary warranty charges. • If the problem with the machine can not be resolved please contact the company that Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
6 burner cooker. • Excessive carbon build up on griddle plates. • Over use of lava rock on the chargrills recommended use by Parry 2kg only. • Faulty electrics – eg, customers plug socket, plug, wiring, junction box fault, wrong fuse.
Page 58
For more detailed information about treatment, recovery and recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product. Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT www.parry.co.uk...
Page 59
Take the unit to an approved waste disposal site; many sites are managed by your local authority. Contact the Parry Group Ltd on the Sales number 01332 875544 for further information on disposal. There will probably be a charge for this service which will depend on the physical location of the unit and size you will be given a collection price for a curb side collection based on commercial rates prevailing at the time.
Need help?
Do you have a question about the ST1050 and is the answer not in the manual?
Questions and answers