EPLACING THE
ULB
Like all light bulbs, UV bulbs have a limited life span. Unlike regular light bulbs that work until they burn out, UV bulbs lose their germicidal
effectiveness over time and must be replaced even though they may still produce light.
After approximately 1 year of continuous use (about 9,000 hours), the UV bulb will lose power and have to be replaced. Replace with a new
Dometic UV bulb. Use of any other bulb will void the warranty.
NOTE
The bulb will still glow blue after 9,000 hours of use, but the UV radiation will not be strong enough to be functional. If the bulb
is glowing red or orange instead of a bright purple-blue, the bulb needs to be replaced immediately.
NOTE
The photocatalytic nano-mesh material does not need to be replaced.
Refer to Figure 7 below and follow these steps to replace the bulb:
1.
Turn off all power breakers running to AU unit before removal of any part of the airhandler.
DANGER
Shock hazard. Turn off all power breakers running to AU unit before removal of any part of the airhandler.
2.
If necessary, close ball valves to isolate the AU airhandler and remove water connections so the AU can be moved to an accessible
location.
3.
On top of the AU, remove the cover screws and lift out the cover panel.
4.
Remove the harness plug from the top of the UV bulb by pulling up gently.
5.
Remove the two screws that secure the bulb bracket to the AU cover.
6.
Remove the two screws that secure the bulb brace to the bracket.
7.
Pull the old bulb up through the bulb bracket to complete the removal process.
8.
Place the new bulb in the bulb bracket by sliding it through the vacant hole.
9.
Insert the two screws that secure the bulb brace to the bracket.
10. Insert the two screws that secure the bulb bracket to the AU cover.
11. Insert the harness plug from the base of the UV Bulb by pushing down gently.
12. On top of the AU, slide in the cover panel and insert the cover screws.
13. Write today's date on the appropriate sticker as a reminder to replace the bulb again a year from this date.
14. Dispose of the old bulb according to local regulations and codes.
CAUTION
Bulb contains hazardous materials and should be disposed of according to local regulations and codes.
Figure 7: Components of the Breathe Easy Retrofit Kit
4
5
COPYRIGHT © 2009 - 2017 Dometic Corporation. All Rights Reserved.
No part of this publication may be reproduced, translated, stored in a retrieval system, or transmitted in any form or by any means electronic, mechanical, photo-
copying, recording or otherwise without prior written consent by Dometic Corporation. Every precaution has been taken in the preparation of this manual to ensure
its accuracy. However, Dometic Corporation assumes no responsibility for errors and omission. Neither is any liability assumed for damages resulting from the use
of this product and information contained herein.
4
1
1
Nano-Mesh Structure
2
2
UV Bulb
3
Bulb Clips (2 pairs)
4
Ballast
5
Wiring Harness
3
TM
Breathe Easy
Air Purifier Retrofit Kit
For Gold Series (AU) Airhandler
Installation Manual
H
I
W
OW
T
ORKS
The Dometic Breathe Easy Air Purifier uses your Gold Series (AU) airhandler to move air through the unit where ultraviolet (UV) light and
innovative Photocatalytic Nano-Mesh technology improve air quality.
The purifier uses a specific frequency of UV light that enables maximum effectiveness in reducing pollutants such as pollen, mold spores,
bacteria, viruses, fumes, and odors, while producing no harmful ozone.
UV energy activates the titanium-dioxide catalyst on the surface of the nano-mesh structure. The molecules of pollutants that come in contact with
the catalyst are reconfigured into nontoxic elements. The density and quantity of pollutants present affect how rapidly the air will be cleaned. As air
re-circulates and makes multiple passes through the system you will notice continuously improving purification levels.
NOTE: The air purifier does not fix the source of ongoing odor problems. For example, a leak causing mold must be repaired and the mold must
be removed.
S
P
AFETY
RECAUTIONS
WARNING
Do not use outdoors.
Keep the cord away from heated surfaces.
Never open the cover without turning off the main breaker.
Never operate this unit if it has a damaged cord or plug.
Never operate this unit if it has been damaged or submerged in water.
Do not place in an area where uncured siliconized sealers are being used, as the vapors will inhibit the unit's photocatalytic
capability.
DANGER
Never look directly at a lit ultraviolet (UV) bulb. The direct power of the UV bulb can be harmful to the eyes. However,
looking at the indirect blue glow from the bulb is safe.
This equipment is not ignition protected per CFR 183.410 and may not be installed in areas that may be exposed to
flammable gas.
S
S
YSTEM
ETUP
Location
This Breathe Easy (BE) retrofit kit is designed only for installation within a Dometic Gold Series (AU) airhandler.
Make sure the ducting that connects to the airhandler is UV-stable. If you can not confirm that it is, replace the ducting in the area
stretching at least 3 feet (1m) before and 3 feet (1m) after the unit with UV-stable ducting to prevent eventual deterioration of the ducting.
Deteriorated ducting may create air leaks that could cause secondary condensation.
WARNING
An air leak at the duct connection could cause secondary condensation to form, resulting in drips & wetness in the surrounding area.
The unit requires annual replacement of the UV bulb, so situate the airhandler for easy access to the air purifier.
The unit requires electricity and operates on 120V or 230V AC power.
The ducting should service an indoor area.
Do not install in areas that may be exposed to flammable gas.
Power
The unit operates on 120V/60Hz or 230V/50Hz or 60Hz AC power and is wired to the incoming power of the air conditioning system. The unit is
configured for 230V/50Hz or 60Hz as a default. If it is to be used for 120V/60Hz the switch on the ballast must be switched to the left to the 120V/
60Hz position. See Figure 6.
See table on next page for electrical specifications and Figure 6 for wiring information. Do NOT wire the unit to blower power, as this will
significantly reduce the life of the UV bulb and cause damage to the ballast. For the most accurate wiring information, always refer to the
wiring diagram on the inside of the electrical box.
L-3270 Revision A - P/N 336899
1

Advertisement

loading

Summary of Contents for Dometic Breathe Easy AU6

  • Page 1 UV bulb and cause damage to the ballast. For the most accurate wiring information, always refer to the copying, recording or otherwise without prior written consent by Dometic Corporation. Every precaution has been taken in the preparation of this manual to ensure wiring diagram on the inside of the electrical box.
  • Page 2 DANGER Never look directly at a lit UV bulb. ELECTRICAL AU12 AU18 AU24 SPECIFICATIONS Figure 5: Installation location of ballast in electric box Volts/Hz/mA 115/60/200 115/60/200 115/60/200 115/60/250 115/60/250 14. Place the UV bulb date sticker on the unit in a clearly visible location and write 220/50/350 220/50/350 220/50/350...

This manual is also suitable for:

Breathe easy au9Breathe easy au12Breathe easy au18Breathe easy au24