standards.
Rectifier type
Bridge rectifier
32 07.23B.0
Half-wave rectifier
32 07.22B.0
Overexcitation rectifier
32 17350E..
Overexcitation rectifier
32 17.2.B..
Table 17/1
Rectifier input voltage (max.)
(VAC)
250
440
550
Table 17/2
Rated input voltage range
U
/VAC (40-60 Hz)
1
up to 400 (+10%)
up to 500 (+10%)
48-120 (±10%)
220-415 (±10%)
480-525 (±10%)
110-230
220-415
Recommended disconnection voltage for DC side switching
Operating Instructions BA 77 600..A00 // Last updated: 13/03/2020 // Page 17 of 33
DC at L-load
(ADC)
no additional
up to 2.0
interference suppression
measures required
no additional
up to 2.0
interference suppression
measures required
no additional
up to 3
interference suppression
measures required
no additional
up to 1.5
interference suppression
up to 1.0
measures required
(V)
700
1200
1500
Capacitor