  • Page 1 Cover page DEHUMIDIFIER APD Series Owner’s Manual Please read this owner’s manual carefully before operating the unit and keep it for future reference. © All rights reserved, ACD, 2019 For models: APD20P APD30P APD45P...
  • Page 2: Table Of Contents

    Table of Contents Operation Notices Explanation of Symbols Exception Clauses Operation Area Safety Precautions Parts Name Check Before Operation Control Panel Basic Functions of the control panel Operation Operation Method Drainage Option Maintenance Cleaning and Maintenance Malfunction Analysis Troubleshooting Error Codes Electric Schematic Diagram NOTICE: Graphics in this manual are only for reference.
  • Page 3: Explanation Of Symbols

    Explanation of Symbols Indicates a hazardous situation that, if not avoided, will result in serious injury or death. Indicates a hazardous situation that, if not avoided, could result in serious injury or death. Indicates a hazardous situation that, if not avoided, may result in minor or moderate injury.
  • Page 4: Operation Area

    Operation Area This dehumidifier is intended for indoor residential applications only. It should not be used for commercial or industrial applications. • Place de dehumidifier on a smooth and level floor. • A dehumidifier operating indoors will have no effect in drying an adjacent enclosed area, such as a closet.
  • Page 5: Safety Precautions

    Safety Precautions Operation and Maintenance • This appliance can be used by children aged from 8 years and above and people with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 6 Safety Precautions Operations and Maintenance • Do not repair the appliance by yourself. It may cause electric shock or damage. Please contact a distributor or manufacturer when you need to repair it. • Do not insert fingers or objects into air inlet or air outlet. It may cause personal injury or damage. •...
  • Page 7 Safety Precautions Wiring • Must follow the electric safety regulations when installing the unit. • According to the local safety regulations, use qualified power supply circuit and circuit breaker. • Install a circuit breaker of adequate capacity only used for the system; otherwise, it may cause malfunction.
  • Page 8 Safety Precautions Wiring • Do not turn the power on before finishing installation. • If the supply cord is damaged, it must be replaced by a qualified person to avoid problems. • The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
  • Page 9 Safety Precautions Location • Do not place the dehumidifier under dripping objects. • Select a location which is out of reach for children and far away from animals. • Instructions for installation and use of this product are provided by the manufacturer. •...
  • Page 10: Parts Name

    Parts Name NOTICE: Actual product may be different from below graphics, please refer to actual product for reference purposes. Front View Back View...
  • Page 11: Check Before Operation

    Check Before Operation Before operation, please first check whether float is properly placed. Below are the checking steps: 1. Hold the handles on both sides of the water bucket and pull it out following the arrow direction on the graphic below. 2.
  • Page 12: Control Panel

    Control Panel NOTICE: • Water bucket must be correctly installed for the dehumidifier to operate. • Do not remove the bucket while unit is in operation. • If you want to use drain hose to drain water away, please install the hose according to section "Drainage option".
  • Page 13 Basic Functions on Control Display NOTICE: • If Nonstop mode is selected, the dehumidifier will operate continuously at its maximum dehumidification settings if attached to a hose to drain or until the bucket is full. • For drier air, press the - button and set to a lower percentage value (%). •...
  • Page 14 Operation FULL The FULL indicator light glows when the bucket is ready to be emptied, or when the bucket is removed or not replaced in the proper position. ALARM If the bucket is full or missing for more than three minutes, an alarm will sound for about 10 seconds to remind you to empty and replace the bucket.
  • Page 15 Drainage Option Option 1: Emptying Manually NOTICE: • Do not remove the bucket when unit is in operation or has just stopped. Otherwise it may cause some water to drip on the floor. • Do not use the hose if using water bucket to collect water. When the hose is connected, water will be drained out through it instead of into the bucket.
  • Page 16 Drainage Option Option 2: Gravity Drain Hose 1. Hose is not provided, so user shall prepare it in advance. [Size: The hose thread should have an outer diameter of 1 1/16 inches (1.0625 inches or 27.0mm), and a pitch of 11.5 TPI.] 2.
  • Page 17: Cleaning And Maintenance

    Cleaning and maintenance • Turn off the unit and disconnect the power before cleaning to avoid electric shock. • Do not wash the unit with water to avoid electric shock. • Do not use volatile liquid to clean the unit. Cleaning the Grille and Case When there is dust on the case, use soft towel to dust it off.
  • Page 18 Cleaning and maintenance APD30P APD45P After cleaning, replace the drain lid and handle and make sure the float of water bucket is placed properly. The side with foam plastic should be beneath the drain lid. Do not remove the foam plastic on the float.
  • Page 19 Cleaning and Maintenance Cleaning the Air Filter Dehumidifier will remind you to clean the air filter when it has been operating for 250 hours. If it is used in dusty places, clean the air filter more often. To remove: Remove the bucket. Grasp the filter edge and pull it straight down and out.
  • Page 20 Cleaning and Maintenance Checking Before Usage 1. Check that air inlets and air outlets are not blocked. 2. Check if circuit breaker and connection are in good condition. 3. Check that filters are clean. 4. Check that drainage hose is not damaged or blocked. Checking After Usage 1.
  • Page 21: Malfunction Analysis

    Malfunction Analysis Please check below items before asking for servicing. If the malfunction still cannot be eliminated, please contact qualified person or manufacturer. NOTICE: Not all the following problems are malfunctions. Phenomenon Possible causes Unit is operating in an area where temperature is higher Dehumidifier is not operating.
  • Page 22 Malfunction Analysis Duhumidifier does not start. Phenomenon Possible Causes Solution Check if power is lost. If yes, wait for the power to restore. If not, check whether the Power is not supplied for the power circuit or power socket has been damaged.
  • Page 23: Error Codes

    Error codes When appliance status is abnormal, temperature indicator on the unit will blink and display corresponding error code. Please refer to list below for identification of error code. Display Malfunction Name Possibles Causes Code Ambient temperature sensor is loosen or is poorly connected with the terminal of display board.
  • Page 24: Electric Schematic Diagram

    Electric Schematic Diagram NOTICE: The electric schematic diagram are subject o change without notice. APD20P, APD30P APD45P...