LG MULTI V ARNU48GBRZ4 Manual page 4

Indoor unit
Hide thumbs Also See for MULTI V ARNU48GBRZ4:
Table of Contents

Advertisement

MULTI V
Indoor Unit
2. Specifications
Model
Cooling Capacity
Heating Capacity
Power Input (H / M / L)
Casing
Dimensions
Body
(WxHxD)
Rows x Columns x FPI
Coil
Face Area
Type
Motor Output x Number
Running Current
Air Flow Rate(H/M/L)
Fan
(High static Mode-factory set)
External Static Pressure
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Safety Device
Liquid Side
Pipe Connections
Gas Side
Drain Pipe(Internal Dia.)
Net Weight
Sound Pressure Levels (H / M / L)
Sound Power Levels (H / M / L)
Power Supply
Refrigerant Control
Transmission cable
Note
1. Capacities are based on the following conditions :
Cooling
• Outdoor temp. 33°C[91.4°F]DB/ 28°C[82.4°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
Heating
• Outdoor temp. 0°C[32°F]DB/ -2.9°C[26.78°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are Net Capacities
3. Due to our policy of innovation some specifications may be changed without prior notification .
4. To be added for more available Models
5. Indoor Unit Connection
No
Connection Condition
Fresh Air Intake Units only are connected
1
with outdoor units
Mixture connection with general Indoor unit
2
and Fresh Intake Unit
6. EEV: Electronic Expansion Valve
7. Sound Level is Standard Mode
(for actual High Mode(factory set) condition, Sound Level may exceed the standard level by 1.5dBA)
8. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
Type
Unit
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h
W
mm
inch
W
A
m³/min
ft³/min
mmAq(Pa)
mm(inch)
mm(inch)
mm
kg(lbs)
dB(A)
dB(A)
Ø, V, Hz
mm²
1) The total capacity of Fresh Air Intake Unit should be 50~100% of outdoor unit.
2) The max quantity of Fresh Air Intake unit is 4 Units.
1) The total capacity of indoor units (standard Indoor Unit + Fresh Air Intake Unit) should be
50~100% of out-door unit.
2) The total capacity of Fresh Air Intake Unit should be less than 30% of the total capacity of
indoor units.
Fresh Air Intake Unit
ARNU76GB8Z4
22.4
19,300
76,400
21.4
18,410
73,080
230 / 200 / 200
Galvanized Steel Plate
1,562 x 460 x 688
61-1/2 x 18-1/8 x 27-3/32
3 x 20 x 19
0.59
Sirocco Fan
375 x 1
1.36
23.7 / 13.2 / 13.2
837 / 446 / 446
22
Direct
BLDC
Microprocessor, Thermostat for cooling and heating
Foamed polystrene
Long Life Filter
Fuse
Ø9.52(3/8)
Ø19.05(3/4)
25
73(161)
45 / 43 / 43
70 / 67 / 67
1, 220 - 240, 50
1, 220, 60
EEV
1.0 ~ 1.5 x 2C
Combination
Fresh Air Intake Unit
ARNU96GB8Z4
28
24,100
95,900
26.7
23,000
91,360
360 / 230 / 230
Galvanized Steel Plate
1,562 x 460 x 688
61-1/2 x 18-1/8 x 27-3/32
3 x 20 x 19
0.59
Sirocco Fan
375 x 1
2.15
35.7 / 23.7 / 23.7
1,261 / 837 / 837
22
Direct
BLDC
Foamed polystrene
Long Life Filter
Fuse
Ø9.52(3/8)
Ø22.2(7/8)
25
73(161)
47 / 45 / 45
72 / 70 / 70
1, 220 - 240, 50
1, 220, 60
EEV
1.0 ~ 1.5 x 2C
4