  • Page 1 Electric Airless Sprayer Important Safety Instructions. Read all warnings and instructions in this manual. Save these instructions. KP330 User Manual...
  • Page 2 WARNING GROUNDING Improper installation or alteration of grounding plug results in risk of electric shock, fire or explosion that could cause serious injury or death. When repair or change the wire, do not plug the ground wire into a flat outlet. Do not alter ground prong or use adapter.
  • Page 3 Component Identification KP330 – Electric Piston Airless Sprayer WARNING EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. Read Technical Data in all equipment manuals.
  • Page 4: Pressure Relief Procedure

    Grounding Pressure Relief Procedure Metal pail: 4.Turn pressure to lowest setting. Hold gun to side of grounded metal flushin g bucket. Improper installation or alteration of grounding plug Trigger gun to relieve pressure, turn prime results in risk of electric shock, fire or explosion To reduce risk of injury from injection, follow that could cause serious injury or death.
  • Page 5 Hold gun against grounded metal flushing pail. Check the intaken of pump for clogs and debris. Trigger sure to 1/2. Flush 1minute. Connect KP330 airless hose, to sprayer. Tighten securely. Do the pressure relif. page 5. Turn pressure control to lowest pressure.
  • Page 6 6. Raise siphon tube above flushing fluid and run Cleanup sprayer for 15 to 30 seconds to drain fluid. Assemble tip and guard Spray 1. Do Pressure Relief, steps 1 - 4(page 5). Remove siphon tube set from paint and place in flushing fluid. NOTE: Use water for water base paint and mineral Spray test pattern.
  • Page 7: Digital Tracking System

    Digital Tracking System Control Board Replacement KP330 Removal Operation Main Menu Relieve pressure, page 5. wait 5 minutes 2.Apply small amount of thermal compound before servicing. to shaded component areas on rear of motor 1.Turn pressure to lowest setting. Trigger gun to 4.
  • Page 8: Drive Housing Replacement

    Drive Housing Replacement Installation CAUTION Do not drop gear cluster when removing drive housing (3). Gear cluster may stay Make sure gear (3) and thrust washers (15,16,17, engaged in motor front end bell or drive 18) are in place (16/17 are copper thrust washers) housing.
  • Page 9: Motor Replacement

    Motor Replacement Coupling Replacement FOR KP330 FOR KP330 Installation Removal Installation Removal 1.Replace the motor,tighten the 4 screws. 1.Push coupling toward input shaft till input shaft 1.Relieve pressure, page 5. surface,tighten screws on coupling. 2.Install the coupling.page 12. 2.Remove coupling,page 12.
  • Page 10: Displacement Pump Replacement

    Motor Replacement Displacement Pump Replacement FOR KP330 Installation Caution If the pump jam nut loosens during operation, Removal Installation threads of the drive housing will be damaged If pump pin works loose, parts could break off Removal due to force of pumping action. Parts could...