Download Print this page
Hide thumbs Also See for Aqua Trac Pro:

Advertisement

Quick Links

2015-18 Aqua Trac Pro
Wiring Manual
Revised January 1, 2018

Advertisement

loading
Need help?

Need help?

Do you have a question about the Aqua Trac Pro and is the answer not in the manual?

Questions and answers

Summary of Contents for AgSense Aqua Trac Pro

  • Page 1 2015-18 Aqua Trac Pro Wiring Manual Revised January 1, 2018...
  • Page 2 Page 20: Connecting the Watermark 200SS Sensor Page 21: Connecting the Watermark 200TS Sensor Page 22: Connecting the ETape Level Sensor Page 23: Connecting the AgSense Tank Monitor Sensor Page 24: G2 200psi Pressure Transducer Wiring Page 25: Pressure Switch or Float Switch Wiring...
  • Page 3 Note 1: Once all sensors are connected and unit is ready to run, you must turn the ON/OFF switch to the “ON” position, and contact your AgSense Dealer to finish setup and configuration of this unit to read the sensors that you have installed.
  • Page 4 Wiring the Solar Panel to the Aqua Trac Unit Wiring the solar panel: Find the group of terminals (2) with the group label PWR 1. Connect the Black Wire (-) from the solar panel to the terminal marked GND as shown above.
  • Page 5 Wiring the Watermark 200SS-V sensor to the Aqua Trac Unit Wiring the Watermark 200SS-V sensor: You can have up to 4 Watermark sensors wired into this unit. Starting with sensor 1, find the group of terminals (3) with the group label WM 1 1.
  • Page 6 Wiring the Decagon 10HS or GS1 sensor to the Aqua Trac Unit Wiring the Decagon 10HS or GS1 sensor: You can have up to 4 Decagon 10HS/GS1 sensors wired into this unit. Starting with sensor 1, find the first group of terminals (3) as shown above.
  • Page 7 Wiring the AquaCheck, Hydrascout, or Wiseone probe to the Aqua Trac Unit Wiring the AquaCheck or Hydrascout probe: Find the group of terminals (3) with the group label Connect the Blue wire from the AquaCheck probe to the terminal marked SIG as shown. Connect the Yellow/Green stripe wire from the AquaCheck probe to the terminal marked GND as shown above.
  • Page 8 Wiring the Sentek soil moisture probe to the Aqua Trac Unit Wiring the Sentek probe: Find the group of terminals (3) with the group label SDI. 1. Connect the Blue wire from the Sentek probe to the terminal marked SIG as shown above.
  • Page 9 Wiring the Decagon 5TM, 5TE, MPS-2 or GS3 Sensors to the Aqua Trac Unit Wiring the Decagon 5TM, 5TE, MPS-2 or GS3 sensor: Find the group of terminals (3) with the group label SDI. 1. Connect the Red wire from the Decagon Sensor to the terminal marked SIG as shown above.
  • Page 10 Wiring the Sentek Drill & Drop Probe to the Aqua Trac Unit Wiring the Sentek probe: Find the group of terminals (3) with the group label SDI. 1. Connect the White wire from the Sentek probe to the terminal marked SIG as shown above.
  • Page 11 Wiring the Campbell Scientific CS650 / CS655 Sensors to the Aqua Trac Unit Wiring the CS650 / CS655 sensors: Find the group of terminals (3) with the group label SDI. 1. Connect the Green wire from the CS Sensor to the terminal marked SIG as shown above. 2.
  • Page 12 Wiring the Acclima TDR315L Sensor to the Aqua Trac Unit Find the group of terminals (3) with the group label SDI. 1. Connect the Blue wire from the Sensor to the terminal marked SIG as shown above. 2. Connect the White wire from the Sensor to the terminal marked GND as shown above. 3.
  • Page 13 Wiring the EnviroPro Soil Moisture Probe to the Aqua Trac Unit Find the group of terminals (3) with the group label SDI. 1. Connect the Blue wire from the Sensor to the terminal marked SIG as shown above. 2. Connect the Black wire from the Sensor to the terminal marked GND as shown above. 3.
  • Page 14 Wiring the Greenshield Soil Moisture Probe to the Aqua Trac Unit Find the group of terminals (3) with the group label SDI. 1. Connect the Green wire from the Sensor to the terminal marked SIG as shown above. 2. Connect the Yellow wire from the Sensor to the terminal marked GND as shown above. 3.
  • Page 15 Wiring the SM100 Soil Moisture Sensor to the Aqua Trac Unit 1. Connect the Red wire from the Sensor to the terminal marked SIG as shown above. 2. Connect the Black wire from the Sensor to the terminal marked GND as shown above. 3.
  • Page 16 Wiring the AgSense Rain Bucket: Find the group of terminals (2) with the group label RAIN 1. Connect the Green wire from the AgSense Rain Bucket to the terminal marked GND as shown above. 2. Connect the Red wire from the AgSense Rain Bucket to the terminal marked RAIN as shown above. Page 14...
  • Page 17 Wiring the AgSense Temperature Sensor to the Aqua Trac Unit Wiring the AgSense Temp Sensor: Find the group of terminals (2) with the group label TEMP 1. Connect the Green wire from the AgSense Temp sensor to the terminal marked GND as shown above.
  • Page 18 How To Configure an Aqua Trac 1. Go to the AgSense users page, click on the unit that you want to set up, then click the main configuration button. 2. Select the type of probe from the drop down menu. Choose AquaCheck or Sentek.
  • Page 19 Updates and Additions New Features/Capabilities: 2013 Aqua Trac Board V3.1 The 2013 Aqua Trac units with circuit boards marked V3.1 can read/use all the sensors on pages 2-7 of this manual, plus 3 new sensors that you will see on the following pages: Page 12: Watermark 200SS Two-Wire soil moisture sensors Page 13: Watermark 200TS Temperature Sensor Page 14: Tank Monitoring Liquid Level Sensor...
  • Page 20 Note 1: Once all sensors are connected and unit is ready to run, you must turn the ON/OFF switch to the “ON” position, and contact your AgSense Dealer to finish setup and configuration of this unit to read the sensors that you have installed.
  • Page 21: Jumper Settings

    Jumper Settings Note: you cannot mix ETape, Watermark/Decagon 10HS/GS1 (5v) sensors and 12v Tank Monitor / Acclima TDR Sensors, only 1 type may be used at a time. Page 19...
  • Page 22 Wiring the Watermark 200SS 2-wire soil moisture sensor to the Aqua Trac V3.1 Wiring the Watermark 200SS sensor: You can have up to 4 Watermark sensors wired into this unit. Starting with sensor 1, find the group of 3 terminals with the group label 1. 1.
  • Page 23 Wiring the Irrometer 200TS Temperature sensor to the Aqua Trac V3.1 Wiring the Watermark Temp Sensor 200TS: Find the group of terminals (2) with the group label TEMP 1. Connect one Red wire from the 200TS Temp sensor to the terminal marked GND as shown above.
  • Page 24 Wiring the ETape Water Level Sensor to the Aqua Trac V3.1 Wiring the ETape Water Level Sensor: (voltage divider type only) You can have up to 4 ETape Sensors wired into this unit. 1. Connect the Black wire from the ETape Sensor to the terminal marked PWR as shown above.
  • Page 25 Aqua Trac V3.1 Wiring the AgSense G3 Tank Monitor sensor: You can have up to 2 Tank Monitor sensors wired into this unit. Starting with sensor 1, find the group of terminals (3) with the group label 1.
  • Page 26 Wiring the G2 200psi Pressure Transducer to the Aqua Trac V3.1 Wiring the AgSense G2 Pressure Transducer: You can have up to 4 Pressure Transducers wired into this unit. 4. Connect the Red wire from the Pressure Transducer to the terminal marked PWR as shown above.
  • Page 27 Wiring a Pressure Switch or Float Switch to the Aqua Trac V3.1 Wiring a Pressure Switch or Float Switch: You can have up to 4 Pressure Switches or Float Switches wired into this unit This wiring assumes using a Normally Open Pressure Swich or Float Switch. OFF=Open Connection, and ON=Closed Connection 1.
  • Page 28 Wiring the KM45 Series Submersible Tank Monitor sensor Wiring the AgSense KM45 Tank Monitor sensor: You can have up to 2 Tank Monitor sensors wired into this unit. Starting with sensor 1, find the group of terminals (3) with the group label 1.
  • Page 29 AgSense. How To Configure an Aqua Trac V3 1. Go to the AgSense users page, click on the unit that you want to set up, then click the main configuration button. 2. If using a soil moisture probe, select the type of probe from the drop down menu.
  • Page 30 Open Circuit Voltage 21.2v DC Short Circuit Current 0.69A Warranty Information: All warranty service provided by the AgSense service center, or an authorized technician. Warranty repairs require a Return Merchandise Authorization Number (RMA); Have your dealer contact AgSense to obtain this RMA number.
  • Page 31 Commander/Crop Link/Aqua Trac relies upon GPS, Satellite and Internet technology which not always functions properly, accordingly, AgSense disclaims any and all responsibility for the reliability of this technology. Customer acknowledges that AgSense does not have the ability to control the reliability of GPS, Satellite and Internet Technology. AgSense specifically disclaims any and all liability for Customer's failure to personally determine whether or not the irrigation equipment that belongs to Customer is functioning properly.
  • Page 32 AgSense, LLC 259 Dakota Ave S PO Box 53 Huron, SD 57350 605-352-8350 www.AgSense.net...