Installation and Operational Instructions for
ROBA
-brake-checker plus DC Type 028.100.2
®
Guidelines on the Declaration of Conformity
A conformity evaluation has been carried out for the product in terms of the EU Low Voltage Directive 2014/35/
EU, the Electromagnetic Compatibility (EMC) Directive 2014/30/EU and RoHS 2011 / 65 / EU with 2015 / 863
EU.
The Declaration of Conformity is laid out in writing in a separate document and can be requested if required.
Guidelines on the EMC Directive (2014/30/EU)
The product cannot be operated independently according to the EMC Directive.
Only after integration of the product into an overall system can this be evaluated in terms of the EMC.
For electronic equipment, the evaluation has been verified for the individual product in laboratory conditions,
but not in the overall system.
Guidelines on the EU Directive 2011 / 65 / EU (RoHS II) with 2015 / 863 EU (RoHS III - from 22
July 2019),
as in products / components (category 11), the proper operation of which is dependent on electric currents
and electromagnetic fields.
Guidelines on the Machinery Directive (2006/42/EC)
The product is a component for installation into machines according to the Machinery Directive 2006/42/EC.
The product can fulfil the specifications for safety-related applications in coordination with other elements.
The type and scope of the required measures result from the machine risk analysis.
The product then becomes a machine component and the machine manufacturer assesses the conformity
of the safety device to the directive. It is forbidden to start use of the product until you have ensured that the
machine accords with the regulations stated in the directive.
Guidelines on the ATEX Directive
Without a conformity evaluation, this product is not suitable for use in areas where there is a high danger
of explosion. For application of this product in areas where there is a high danger of explosion, it must be
classified and marked according to Directive 2014/34/EU.
Guidelines on the REACH Regulation (EC No. 1907/2006)
of the European Parliament and of the Council Concerning the Registration, Evaluation, Authorisation and Re-
striction of Chemicals. This regulates the manufacture, placing on the market and use of chemical substances
in preparations, under certain conditions also pertaining to substances in products. mayr
exclusively manufactures products articles: clutches/couplings, electric motors, brakes and the appropriate
rectifiers) in accordance with the definition in Article 3 Section 3 of the REACH Regulation.
28/06/2019 HH/GF/GC
Page 1 of 12
which restrict the use of certain hazardous substances in electrical and electronic devices as well
Chr. Mayr GmbH + Co. KG
Eichenstraße 1, D-87665 Mauerstetten, Germany
Tel.: +49 8341 804-0, Fax: +49 8341 804-421
www.mayr.com, E-Mail:
info@mayr.com
(B.0281002.EN)
power transmission
®
your reliable partner
1 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ROBA-brake-checker plus DC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Mayr ROBA-brake-checker plus DC

  • Page 1 European Parliament and of the Council Concerning the Registration, Evaluation, Authorisation and Re- striction of Chemicals. This regulates the manufacture, placing on the market and use of chemical substances in preparations, under certain conditions also pertaining to substances in products. mayr power transmission ®...
  • Page 2: General Safety Guidelines

    Safety Regulations. Incorrect operation can vertent switch-on. cause injury or damage. 28/06/2019 HH/GF/GC Chr. Mayr GmbH + Co. KG Eichenstraße 1, D-87665 Mauerstetten, Germany Tel.: +49 8341 804-0, Fax: +49 8341 804-421 your reliable partner Page 2 of 12 www.mayr.com, E-Mail:...
  • Page 3 • Rising coil temperature • Falling supply voltage • Line voltage drop on feed lines to the brake 28/06/2019 HH/GF/GC Chr. Mayr GmbH + Co. KG Eichenstraße 1, D-87665 Mauerstetten, Germany Tel.: +49 8341 804-0, Fax: +49 8341 804-421 your reliable partner Page 3 of 12 www.mayr.com, E-Mail:...
  • Page 4: Technical Data

    ® expressly not approved by mayr power transmission. ® In these cases, operation is at your own risk, the guarantee and service and support provided by mayr ® power transmission no longer apply. 28/06/2019 HH/GF/GC Chr. Mayr GmbH + Co. KG Eichenstraße 1, D-87665 Mauerstetten, Germany...
  • Page 5: Wiring Example

    In case of an invalid or incorrect setting, the ROBA -brake-checker monitoring module does not function. ® 28/06/2019 HH/GF/GC Chr. Mayr GmbH + Co. KG Eichenstraße 1, D-87665 Mauerstetten, Germany Tel.: +49 8341 804-0, Fax: +49 8341 804-421 your reliable partner Page 5 of 12 www.mayr.com, E-Mail:...
  • Page 6 For the calculation, a simplified Parts-Count procedure has Overexcitation time been used (EN ISO 13849-1) Holding voltage 28/06/2019 HH/GF/GC Chr. Mayr GmbH + Co. KG Eichenstraße 1, D-87665 Mauerstetten, Germany Tel.: +49 8341 804-0, Fax: +49 8341 804-421 your reliable partner Page 6 of 12 www.mayr.com, E-Mail:...
  • Page 7: Time Delays

    Signal delay ≤ 20 ms (manually) (automatically) Manufacturer-side setting 28/06/2019 HH/GF/GC Chr. Mayr GmbH + Co. KG Eichenstraße 1, D-87665 Mauerstetten, Germany Tel.: +49 8341 804-0, Fax: +49 8341 804-421 your reliable partner Page 7 of 12 www.mayr.com, E-Mail: info@mayr.com...
  • Page 8 Type 4/028.100.2 ≤ 45 °C ≤ 75 °C [VDC] [VDC] 28/06/2019 HH/GF/GC Chr. Mayr GmbH + Co. KG Eichenstraße 1, D-87665 Mauerstetten, Germany Tel.: +49 8341 804-0, Fax: +49 8341 804-421 your reliable partner Page 8 of 12 www.mayr.com, E-Mail:...
  • Page 9: Cycle Frequency

    WE74271221). The device has been inspected individually only for industrial areas. 28/06/2019 HH/GF/GC Chr. Mayr GmbH + Co. KG Eichenstraße 1, D-87665 Mauerstetten, Germany Tel.: +49 8341 804-0, Fax: +49 8341 804-421 your reliable partner Page 9 of 12 www.mayr.com, E-Mail:...
  • Page 10 Installation and Operational Instructions for ROBA -brake-checker plus DC Type 028.100.2 ® (B.0281002.EN) 28/06/2019 HH/GF/GC Chr. Mayr GmbH + Co. KG Eichenstraße 1, D-87665 Mauerstetten, Germany Tel.: +49 8341 804-0, Fax: +49 8341 804-421 your reliable partner Page 10 of 12 www.mayr.com, E-Mail:...
  • Page 11: Intended Use

    Code No. 160216 (Code No. acc. 200/532/EC), or can be disposed of by a certified disposal firm. 28/06/2019 HH/GF/GC Chr. Mayr GmbH + Co. KG Eichenstraße 1, D-87665 Mauerstetten, Germany Tel.: +49 8341 804-0, Fax: +49 8341 804-421 your reliable partner Page 11 of 12 www.mayr.com, E-Mail:...
  • Page 12 Deactivate the DIP switch for voltage reduction not reached mechanism is activated mechanism 28/06/2019 HH/GF/GC Chr. Mayr GmbH + Co. KG Eichenstraße 1, D-87665 Mauerstetten, Germany Tel.: +49 8341 804-0, Fax: +49 8341 804-421 your reliable partner Page 12 of 12 www.mayr.com, E-Mail:...

This manual is also suitable for:

2/028.100.24/028.100.2

Table of Contents