Table of Contents

Advertisement

 
KRYPTON®  
TECHNICAL REFERENCE MANUAL  
KRYPTON V20-1  
 
 
 
 
1  
/

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Krypton and is the answer not in the manual?

Questions and answers

Summary of Contents for DEWESOFT Krypton

  • Page 1   KRYPTON®   TECHNICAL REFERENCE MANUAL   KRYPTON V20-1           1  ...
  • Page 2: Table Of Contents

    4.1.2. Small and Flexible Data Acquisition 23   4.1.3. Robust and rugged Data Acquisition 23   4.1.4. High-end signal conditioning 24   4.1.5. KRYPTON ONE - Single channel Data Acquisition 25   4.1.6. DAQ Synchronization 25   4.2. General specifications 26  ...
  • Page 3 50   5.6.5. KRYPTONi-4xDI 51   5.6.6. KRYPTONi-4xDO 51   5.6.7. DIO: connectors 52   5.6.7.1. KRYPTON Multichannel DIO modules: connectors 52   5.6.7.2. Krypton 4xDI and 4xDO connectors 54   5.7. HV: High Voltage 55   5.7.1. HV: specifications 55  ...
  • Page 4 5.12.6. TH: wiring diagrams 84   5.12.6.1. KRYPTONi-8xTH, KRYPTONi-16xTH: Voltage 84   5.12.6.2. KRYPTONi-8xTH, KRYPTONi-16xTH: Temperature 85   5.12.6.3. KRYPTONi-1xTH-HV: Temperature 87   6. KRYPTON CPU 88   6.1. KRYPTON CPU: specifications 89   KRYPTON® V20-1 4 / 141    ...
  • Page 5 KRYPTON®   TECHNICAL REFERENCE MANUAL       6.2. KRYPTON CPU: dimensions 90   6.3. Connectors 91   6.3.1. Pinout : Power In Connector 91   7. KRYPTON Accessories 92   7.1. KRYPTON Power Supply 92   7.2. KRYPTON-CPU Power Supply 92  ...
  • Page 6 KRYPTON®   TECHNICAL REFERENCE MANUAL       9.4. Distributed system with Krypton ONE 121   9.5. Ecat Sync Junction/Ecat GPS Junction 122   9.6. Connecting SIRIUS-R4 and Krypton STG 124   9.7. Soft-Sync connection 124   9.8. Mixed system 125  ...
  • Page 7: About This Document

    A description of the system and the main combination and expansion options   ● The description of the connection variants and the pin assignments on the inputs and outputs   ● A comprehensive introduction to the configuration of the slices using Dewesoft software.   ● Technical data    ●...
  • Page 8: Online Versions

    The latest version of the DEWESoft® tutorials can be found here:   https://download.dewesoft.com/list/manuals-brochures/software-manuals   In the Software Manuals section click the download link of the DEWESoft X3 User Manual entry.     Important   Read safety instructions first in chapter Safety instructions .
  • Page 9: Getting Started

        3. Getting started   This chapter will help you to install the software, connect your Krypton system to the PC via EtherCAT,   and will show you how to configure Dewesoft.      To follow these steps, you need the following items:   ...
  • Page 10: Dewesoft Settings Krypton

    DeweSoft settings     In the Devices section, you can see the connected Krypton device. When you select one of them, the   properties pane at the right will show the related data e.g. Serial number, Firmware version, etc.  ...
  • Page 11: Channel Setup Krypton

    KRYPTON®   TECHNICAL REFERENCE MANUAL       3.2.2. Channel setup Krypton   When Dewesoft has started up, you will be in Measure mode and see the Setup files list or you can              ...
  • Page 12: Simple Measurement

    Manual from the pop-up menu .       Help - Manual     3.3.2. Analogue channel setup    In the analogue channel setup screen you can see all channels of your connected Krypton systems. Per            ...
  • Page 13: Sample Rate

                          for Krypton devices. For example the STG module has max. 20 kS/sec and TH module has a max. 100                    ...
  • Page 14: Measurement Mode

                    button.     Now Dewesoft has created a datafile with all the data that you have seen during the recording session.                      ...
  • Page 15: Analyse Mode

        3.3.5. Analyse Mode   When you have just stopped a measurement, Dewesoft will automatically open the last recorded data   file in Review mode, so that you can start the analysis right away.     Analyse mode  ...
  • Page 16: Advanced Configuration

    TECHNICAL REFERENCE MANUAL       3.4. Advanced configuration    Note, that the Dewesoft launcher has already done the hardware setup for you – you can check this in   ❶ ❷ the Settings dialogue. Click the Options button – and then click the Settings menu item .
  • Page 17: Firmware Upgrade

    (.dxu file) from the Dewesoft downloads page under   ● the section Drivers.    Copy the file into the Firmwares folder of your Dewesoft installation (e.g.   ● D:\DewesoftX\System\X3\Firmwares).    Connect the Dewesoft instrument to the PC and run Dewesoft X3.   ...
  • Page 18: Licensing

      Licensing options     Hint   All licenses regarding Krypton will only work when the Krypton system is connected to your PC   and the device has been activated in the hardware setup.          KRYPTON® V20-1...
  • Page 19: Troubleshooting

                    ● switches or hubs      If the computer is still having trouble recognizing the Dewesoft EtherCAT devices, here are some                      ...
  • Page 20 KRYPTON®   TECHNICAL REFERENCE MANUAL       If the driver is not installed, it can be downloaded from our web page   If the driver is already installed and the devices are still not recognized, the Speed & Duplex of the  ...
  • Page 21: System Overview

    Rugged and distributed EtherCAT data acquisition system for field measurement in extreme and harsh   environments. KRYPTON DAQ systems offer IP67 degree of protection and can operate in the extreme   temperature range from -40 to +85 °C and offer high shock protection.  ...
  • Page 22: Main Features

                        sync.     UP TO 100m BETWEEN UNITS: KRYPTON units can be distributed over the large area with the distances                    ...
  • Page 23: Small And Flexible Data Acquisition

                          rubber. As a final touch, we add rubber bands around the KRYPTON chassis to further protect the unit                      ...
  • Page 24: High-End Signal Conditioning

    KRYPTON®   TECHNICAL REFERENCE MANUAL       4.1.4. High-end signal conditioning       KRYPTON is not just small and rugged but also has quality                         analog amplifiers for precise signal measurement. An  ...
  • Page 25: Krypton One - Single Channel Data Acquisition

              KRYPTON modules runs through the same cable as power and data.     KRYPTON DAQ modules can also be combined and synchronized with our fast USB DAQ devices like            ...
  • Page 26: General Specifications

    KRYPTON®   TECHNICAL REFERENCE MANUAL       4.2. General specifications   Interface   Data interface   EtherCAT®   Data Rate   100 Mbps Full Duplex bus speed   Max. Throughput per Chain   From 6 MB/s to 10 MB/s  ...
  • Page 27: Krypton Modules

                          rubber. As a final touch we add rubber band around the KRYPTON chassis to further protect the unit                      ...
  • Page 28: Overview

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.1. Overview   5.1.1. KRYPTON Multichannel     STG   TH   RTD   ACC   LV   LA   DIO   Connectors   DB9, L2B10f   Thermocouple   L0B6f   BNC  ...
  • Page 29: Krypton Single Width

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.1.1.1. KRYPTON single width     Dimensions : KRYPTON single       KRYPTON® V20-1 29 / 141    ...
  • Page 30: Krypton Dual Width

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.1.1.2. KRYPTON dual width     Dimensions : KRYPTON dual       KRYPTON® V20-1 30 / 141    ...
  • Page 31: Krypton One

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.1.2. KRYPTON ONE     AO   DI   DO   ACC   STG   LV   HV   TH-HV   CNT   Input /   Output:   Input:   Output:  ...
  • Page 32: Krypton One Form Factor

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.1.2.1. KRYPTON ONE form factor     Dimensions : KRYPTON one                     KRYPTON® V20-1 32 / 141    ...
  • Page 33: General Connection Diagrams

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.1.3. General connection diagrams   In illustration below “ Typical connection diagrams ” parts of the measurement chain are shown:    Amplifier   ● Connections   ● Sensor   ●    ...
  • Page 34: Acc: Accelerometer

    The ACC modules have BNC input connectors and are perfect for sound and vibration IEPE channels.   5.2.1. ACC: specifications     KRYPTON-4xACC, 8xACC   Analog inputs   KRYPTON-4xACC, KRYPTON-8xACC   Input type   Voltage, IEPE   Number of channels   4 (4xACC), 8 (8xACC)   ADC Type  ...
  • Page 35 KRYPTON®   TECHNICAL REFERENCE MANUAL       Dimensions with Connectors   213 x 39 x 66.8 mm   213 x 54 x 66.8 mm   1) Depending on the mating connector types     KRYPTONi-1xACC   Analog inputs  ...
  • Page 36: Krypton-8Xacc

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.2.2. KRYPTON-8xACC   KRYPTON-8xACC module has 8 BNC connectors for voltage and IEPE measurements.     Caution   Inputs are single ended, isolated sensors must be used         KRYPTON-8xACC  ...
  • Page 37: Kryptoni-1Xacc

      KRYPTONi-1xACC     KRYPTON-1xACC can work with 50 kHz if it is the only one in the EtherCAT chain. This feature is   useful for the microphone measurements where 50 kHz sampling rate is required.     5.2.5. ACC: Connectors  ...
  • Page 38: Acc: Wiring Diagrams

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.2.6. ACC: Wiring diagrams   5.2.6.1. ACC: Voltage       5.2.6.2. ACC: IEPE           KRYPTON® V20-1 38 / 141    ...
  • Page 39: Ao: Analog Out

    62 x 56 x 29 mm   Weight   250 g   1) Only asynchronous mode is supported in Dewesoft, function generator is not supported   2) Only DC output voltage, function generator not supported   3) Depending on the mating connector types  ...
  • Page 40: Krypton-1Xao

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.3.2. KRYPTON-1xAO     KRYPTON - 1xAO     5.3.3. AO: connectors       Pin   Name   Description   1   Out +   Output +   2   Out -  ...
  • Page 41: Can: Controller Area Network

                  KRYPTON CAN devices support OBDII, J1939 standard protocols and can output CAN messages.   5.4.1. CAN: specifications     KRYPTONi-2xCAN-USB     KRYPTONi-2xCAN USB   CAN ports specification   Number of ports  ...
  • Page 42: Kryptoni-2Xcan-Usb

    KRYPTON®   TECHNICAL REFERENCE MANUAL       KRYPTONi-1xCAN, KRYPTONi-1xCAN-FD   CAN ports specification   Number of ports   1   1   Interface type   CAN 2.0B   CAN-FD, CAN 2.0B   Interface data rate   up to 1 Mbit/sec  ...
  • Page 43: Kryptoni-1Xcan

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.4.3. KRYPTONi-1xCAN   KRYPTONi-1xCAN is a single port CAN device that uses EtherCAT as an interface.       KRYPTONi-1xCAN     5.4.4. KRYPTONi-1xCAN-FD   KRYPTONi-1xCAN-FD is a single port CAN-FD device that uses EtherCAT as a data interface. The CAN-FD  ...
  • Page 44: Can: Connectors

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.4.5. CAN: connectors     Pin   Name   Description   5 V supply   1   +5V   max. current: 500 mA   2   CAN_LOW   CAN low   3  ...
  • Page 45: Cnt: Counter

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.5. CNT: Counter   Single channel KRYPTON counter module utilizes a patented technology called SUPERCOUNTER in                         every of its counter/encoder inputs and in the smallest possible form. It supports counting, waveform  ...
  • Page 46: Krypton-1Xcnt

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.5.2. KRYPTON-1xCNT   KRYPTON-1xCNT has a LEMO 7-pin L1T7f connector.     KRYPTON-1xCNT     5.5.3. CNT: connectors       Pin   Name   Description   1   IN0/A   Input A  ...
  • Page 47: Dio: Digital Input/Output

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.6. DIO: Digital Input/Output   KRYPTON digital input/output modules are perfect choices for control applications.   5.6.1. DIO: specifications     KRYPTONi-16xDI, 8xDI-8xDO, 16xDO     KRYPTONi-16xDI   KRYPTONi-8xDI-8xDO   KRYPTONi-16xDO  ...
  • Page 48 KRYPTON®   TECHNICAL REFERENCE MANUAL       KRYPTONi-4xDI   Digital Inputs   Input type   Digital   Number of channels   4   Connector   DSUB15HD Male   Compatibility   TTL / CMOS Voltage Levels   Input low level  ...
  • Page 49: Kryptoni-16Xdi

    KRYPTON®   TECHNICAL REFERENCE MANUAL       KRYPTONi-4xDO   Digital Outputs   Output type   Digital   Number of channels   4   Connector   DSUB15HD Female   Maximum update rate   depends on EtherCAT master cycle time  ...
  • Page 50: Kryptoni-16Xdo

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.6.3. KRYPTONi-16xDO   KRYPTONi-16xDO module has 16 digital output channels: 8 on each of the two 25-pin DSUB female   connectors.       KRYPTONi-8xDI-8xDO   5.6.4. KRYPTONi-8xDI-8xDO   KRYPTONi-8xDI-8xDO module has 8 digital input channels (25-pin DSUB male connector) and 8 digital  ...
  • Page 51: Kryptoni-4Xdi

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.6.5. KRYPTONi-4xDI   Single channel isolated KRYPTON module with 4 digital inputs and power supply on the front 15-pin   DSUB male connector.     KRYPTONi-4xDI     5.6.6. KRYPTONi-4xDO   Single channel isolated KRYPTON module with 4 digital outputs and power supply on the front 15-pin  ...
  • Page 52: Dio: Connectors

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.6.7. DIO: connectors   5.6.7.1. KRYPTON Multichannel DIO modules: connectors           Digital output: DSUB-25 female   Digital input: DSUB-25 male           KRYPTON® V20-1 52 / 141    ...
  • Page 53 KRYPTON®   TECHNICAL REFERENCE MANUAL         8xDI   8xDO   Pin   Name   Description   Name   Description   1   DI1+   Digital input CH1 +   DO1   Digital output CH1   2  ...
  • Page 54: Krypton 4Xdi And 4Xdo Connectors

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.6.7.2. Krypton 4xDI and 4xDO connectors       DSUB-15 HD male for Krypton 4xDI   DSUB-15 HD female for Krypton 4xDO       4xDO   4xDI     Pin  ...
  • Page 55: Hv: High Voltage

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.7. HV: High Voltage   Single channel high voltage input DAQ device. Isolation category is CATII 1000V.   5.7.1. HV: specifications   Analog Input   Input types   Voltage   Number of channels  ...
  • Page 56: Kryptoni-1Xhv

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.7.2. KRYPTONi-1xHV   KRYPTONi-1xHV has a banana front connector for high voltage measurement.     KRYPTONi-1xHV     5.7.3. HV: connectors       Pin   Name   Description   1  ...
  • Page 57: Hv: Wiring Diagrams

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.7.4. HV: wiring diagrams   5.7.4.1. HV: Voltage         KRYPTON® V20-1 57 / 141    ...
  • Page 58: La: Low Amperage

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.8. LA: Low Amperage   KRYPTON LA modules are rugged isolated DAQ devices for low amperage measurements.     5.8.1. LA: specifications     Analog input   KRYPTONi-8xLA   Input type  ...
  • Page 59: Kryptoni-8Xla

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.8.2. KRYPTONi-8xLA   KRYPTONi-8xLA has 8 BNC input connectors for current measurement.     KRYPTONi-8xLA   5.8.3. LA: connectors     Pin   Name   Description   1   In+   Input +  ...
  • Page 60: La: Wiring Diagrams

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.8.4. LA: wiring diagrams   5.8.4.1. LA: Current           KRYPTON® V20-1 60 / 141    ...
  • Page 61: Low Voltage

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.9. LV: Low Voltage   KRYPTON LV modules are rugged isolated DAQ devices for low voltage measurements.   5.9.1. LV: specifications   KRYPTONi-4xLV, 8xLV   Analog input   KRYPTONi-4xLV   KRYPTONi-8xLV  ...
  • Page 62 KRYPTON®   TECHNICAL REFERENCE MANUAL       KRYPTONi-1xLV   Analog input   Input types   Voltage   Number of channels   1   Input connector   BNC   ADC Type   24-bit SAR with anti-aliasing filter   Sampling Rate  ...
  • Page 63: Kryptoni-8Xlv

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.9.2. KRYPTONi-8xLV   KRYPTONi-8xLV has 8 BNC input connectors for voltage measurement.       KRYPTONi-8xLV   5.9.3. KRYPTONi-4xLV   KRYPTONi-4xLV has 4 BNC input connectors for voltage measurement.     KRYPTONi-4xLV  ...
  • Page 64: Kryptoni-1Xlv

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.9.4. KRYPTONi-1xLV   KRYPTONi-1xLV is a single channel low voltage module with BNC connector.     KRYPTONi-1xLV     5.9.5. LV: connectors       Pin   Name   Description   1  ...
  • Page 65: Wiring Diagrams

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.9.6. LV: wiring diagrams   5.9.6.1. LV: Voltage             KRYPTON® V20-1 65 / 141    ...
  • Page 66: Rtd: Resistance Temperature Detector

      5.10. RTD: Resistance Temperature Detector   KRYPTON RTD module with 6-pin Lemo 0B input connectors is used for measurements with universal   platinum thermometer probes, thermistors, as well as for resistance and voltage measurements.   5.10.1. RTD: specifications  ...
  • Page 67: Kryptoni-8Xrtd

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.10.2. KRYPTONi-8xRTD     KRYPTONi-8xRTD     5.10.3. RTD: connectors         Pin   Name   Description   1   In+   Input +   2   In-   Input-  ...
  • Page 68: Rtd: Wiring Diagrams

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.10.4. RTD: wiring diagrams   5.10.4.1. RTD: Voltage       5.10.4.2. RTD: Resistance       KRYPTON® V20-1 68 / 141    ...
  • Page 69: Rtd: Temperature (3-Wire)

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.10.4.3. RTD: Temperature (3-wire)       5.10.4.4. RTD: Temperature (4-wire)         KRYPTON® V20-1 69 / 141    ...
  • Page 70: Stg: Strain Gauge

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.11. STG: Strain Gauge   KRYPTON STG modules have universal differential voltage and Full / Half / Quarter bridge input. STG                        ...
  • Page 71 KRYPTON®   TECHNICAL REFERENCE MANUAL       Internal Shunt Resistor   100 kΩ (others on request)   Shunt Resistor Accuracy   0.1 %; TCR: 10 ppm/K (others on request)   Input Short, Sensor Offset Adjust   Software-selectable   Additional Specifications  ...
  • Page 72 KRYPTON®   TECHNICAL REFERENCE MANUAL       KRYPTONi-1xSTG   Analog input - Voltage   Input types   Voltage, current, full bridge strain, half bridge strain, quarter bridge strain   Number of channels   1   Input connector   DB9  ...
  • Page 73: Krypton-6Xstg

    Physical   Dimensions   62 x 56 x 29 mm   Weight   250 g     5.11.2. KRYPTON-6xSTG   KRYPTON-6xSTG module has 6 DSUB-9 female connectors for voltage or strain measurement.     KRYPTON-6xSTG     5.11.3. KRYPTON-6xSTG-L2B10f  ...
  • Page 74: Krypton-3Xstg

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.11.4. KRYPTON-3xSTG   KRYPTON-3xSTG module has 3 DSUB-9 female connectors for voltage or strain measurement.       KRYPTON-3xSTG     5.11.5. KRYPTON-3xSTG-L2B10fs   KRYPTON-3xSTG-L2B10fs module has 3 LEMO L2B10fs connectors for voltage or strain measurement.  ...
  • Page 75: Kryptoni-1Xstg

    KRYPTON®   TECHNICAL REFERENCE MANUAL         5.11.6. KRYPTONi-1xSTG   KRYPTONi-1xSTG is the world’s only single channel perfect strain gauge DAQ device. KRYPTONi-1xSTG is                            ...
  • Page 76 KRYPTON®   TECHNICAL REFERENCE MANUAL             Pin   Name   Description   1   TEDS   TEDS   2   R+   ¼ Bridge /   Shunt   3   NC   Not   connected  ...
  • Page 77: Stg: Wiring Diagrams

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.11.8. STG: wiring diagrams   5.11.8.1. STG: Voltage   Single ended   Differential     Use only when sensor Output (+) and Output (-)     are referenced to Gnd. Gnd must be connected.  ...
  • Page 78: Stg: Bridge

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.11.8.2. STG: Bridge   Full-bridge   Half-bridge       Quarter-bridge             KRYPTON® V20-1 78 / 141    ...
  • Page 79: Stg: Current

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.11.8.3. STG: Current     External direct shunt   External loop powered shunt       Internal shunt     This feature is limited only to KRYPTONi-1xSTG.   KRYPTON® V20-1 79 / 141    ...
  • Page 80: Stg: Potentiometer

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.11.8.4. STG: Potentiometer           KRYPTON® V20-1 80 / 141    ...
  • Page 81: Th: Thermocouple

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.12. TH: Thermocouple   KRYPTON TH modules are isolated rugged DAQ devices for temperature measurements using   thermocouples.   5.12.1. TH: specifications     KRYPTONi-8xTH, 16xTH   Analog inputs   KRYPTONi-8xTH  ...
  • Page 82: Kryptoni-8Xth

    1.3 W (typ.)   Physical   Dimensions   62 x 56 x 36 mm   Weight   300 g     KRYPTON TH ACCURACY   Temperatur Type K   Type J   Type T   Type R   Type S  ...
  • Page 83: Kryptoni-16Xth

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.12.3. KRYPTONi-16xTH   KRYPTONi-16xTH module has 16 thermocouple-connectors for temperature measurement.       KRYPTONi-16xTH 5.12.4. KRYPTONi-1xTH-HV   KRYPTONi-1xTH-HV is a single channel isolated module with LEMO REDEL H02 input connector for  ...
  • Page 84: Th: Connectors

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.12.5. TH: connectors       Pin   Name   Description   1   In+   Input+     2   In-   Input-   Thermocouple connector: pin-out (Mini TC)    ...
  • Page 85: Kryptoni-8Xth, Kryptoni-16Xth: Temperature

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.12.6.2. KRYPTONi-8xTH, KRYPTONi-16xTH: Temperature     T-type thermocouple   S-type, R-type thermocouple       N-type thermocouple   K-type thermocouple       KRYPTON® V20-1 85 / 141    ...
  • Page 86 KRYPTON®   TECHNICAL REFERENCE MANUAL       J-type thermocouple   E-type thermocouple             B-type thermocouple   C-type thermocouple             KRYPTON® V20-1 86 / 141    ...
  • Page 87: Kryptoni-1Xth-Hv: Temperature

    KRYPTON®   TECHNICAL REFERENCE MANUAL       5.12.6.3. KRYPTONi-1xTH-HV: Temperature   K-type thermocouple             KRYPTON® V20-1 87 / 141    ...
  • Page 88: Krypton Cpu

              ranging from -40 °C to 70 °C.   SMALLEST DATA LOGGER: KRYPTON CPU is a very small data logger and is ready to be placed in tight                ...
  • Page 89: Krypton Cpu: Specifications

    KRYPTON®   TECHNICAL REFERENCE MANUAL       6.1. KRYPTON CPU: specifications     Computer   Processor   Intel® Atom™ Quad Core at 1.91 GHz   Memory   4 GB   Storage   Non-removable 240 GB mSATA SSD   Interfaces and options  ...
  • Page 90: Krypton Cpu: Dimensions

    KRYPTON®   TECHNICAL REFERENCE MANUAL       6.2. KRYPTON CPU: dimensions     Dimensions-KRYPTON CPU       KRYPTON® V20-1 90 / 141    ...
  • Page 91: Connectors

    KRYPTON®   TECHNICAL REFERENCE MANUAL       6.3. Connectors   Name   Description   Power In   3-pin LEMO male connector   USB   3x USB 2.0 connector   Ethernet   RJ-45 connector   EtherCAT   8-pin LEMO connector  ...
  • Page 92: Krypton Accessories

    KRYPTON®   TECHNICAL REFERENCE MANUAL       7. KRYPTON Accessories   7.1. KRYPTON Power Supply   The KRYPTON Power Supply is available as an option in our web-shop. You can connect the LEMO 8-pin            ...
  • Page 93: Ecat Power Junction

    The ECAT Power Junction box (article number: ECAT-POWER-JUNCTION) can be used to inject power   into the Ethernet connection between your PC and the KRYPTON modules: so that you only have one   cable for power and data to your KRYPTON modules.  ...
  • Page 94: Pinout : Power In Connector

    KRYPTON®   TECHNICAL REFERENCE MANUAL       7.3.1. Pinout : Power in connector         Pin   Name   Description   1   IN+   Input +   2   IN-   Input -      ...
  • Page 95: Pinout : Ethercat Connector

    KRYPTON®   TECHNICAL REFERENCE MANUAL       7.3.3. Pinout : EtherCAT connector         Pin   Name   Description   1   TX_P   Transmission +   2   TX_N   Transmission -   3   RX_P  ...
  • Page 96: Ecat Power Injector

                              the Ethernet connection between KRYPTON modules, when you can have a very long measurement                          ...
  • Page 97: Pinout : Pwr Connector

    KRYPTON®   TECHNICAL REFERENCE MANUAL       7.4.1. Pinout : PWR connector       Pin   Name   Description   1   -   -   2   -   -   3   -   -  ...
  • Page 98: Pinout: Ethercat In Connector

    KRYPTON®   TECHNICAL REFERENCE MANUAL       7.4.3. Pinout: EtherCAT IN connector   The connector for EtherCAT is a LEMO 1B 8-pin male connector.           Pin   Name   Description   1   TX_P  ...
  • Page 99: Ecat Sync Junction

    EtherCAT input connector:   e.g. connection to the PC via L1T8f-RJ45-1M cable   OUT   8-pin LEMO   EtherCAT output connector to your Krypton slice/s   use any of the ECAT to ECAT expansion cables (e.g.   L1T8m-L1T8f-10M).   SYNC  ...
  • Page 100: Pinout : Ethercat Out Connector

    KRYPTON®   TECHNICAL REFERENCE MANUAL       7.5.1. Pinout : EtherCAT out connector       Pin   Name   Description   1   TX_P   Transmission +   2   TX_N   Transmission -   3   RX_P  ...
  • Page 101: Pinout: Sync Connector

    KRYPTON®   TECHNICAL REFERENCE MANUAL       7.5.3. Pinout: Sync connector       Pin   Name   Description   1   CLK   Clock   2   Trigg   Trigger   3   GPS-PPS   GPS - PPS  ...
  • Page 102: Ecat Sync Junction: Specifications

    KRYPTON®   TECHNICAL REFERENCE MANUAL       7.5.4. ECAT Sync Junction: Specifications     Interface   Data interface   EtherCAT®   Data Rate   100 Mbps Full Duplex bus speed   Max. Throughput per Chain   From 6 MB/s to 10 MB/s  ...
  • Page 103: Ecat Gps Junction

    KRYPTON®   TECHNICAL REFERENCE MANUAL       7.6. ECAT GPS Junction   ECAT GPS Junction is used for synchronization between SIRIUS-EtherCAT or KRYPTON series to SIRIUS,                          ...
  • Page 104: Pinout : Ethercat Out Connector

    KRYPTON®   TECHNICAL REFERENCE MANUAL       7.6.1. Pinout : EtherCAT out connector       Pin   Name   Description   1   TX_P   Transmission +   2   TX_N   Transmission -   3   RX_P  ...
  • Page 105: Pinout: Sync Connector

    KRYPTON®   TECHNICAL REFERENCE MANUAL       7.6.3. Pinout: Sync connector       Pin   Name   Description   1   CLK   Clock   2   Trigg   Trigger   3   GPS-PPS   GPS - PPS  ...
  • Page 106: Hardware Overview

        Data, Sync and Power connection between the   ECAT to ECAT         Krypton™ slices, the Sirus EtherCAT slice and   L1T8m - L1T8f    DS-EtherCAT   DS-EtherCAT   the Krypton CPU.   device IN  ...
  • Page 107: Pinout: Out Connector

    KRYPTON®   TECHNICAL REFERENCE MANUAL       8.1.3. Pinout: OUT connector   OUT connector for EtherCAT is a LEMO 1B 8-pin female connector.       Pin   Name   Description   1   TX_P   Transmission +  ...
  • Page 108: Leds Blinking Codes

    . The LED blinking codes adhere to the EtherCAT   specification.      L means Link : i.e. the In- (left L-LED) or Out-connector (right L-LED) is linked to another Krypton   ● slice or to the measurement PC,   ...
  • Page 109: Pre-Op State

                            blinking fast. DeweSoft will set the Krypton slice in the PRE-OP state when you enter the Device settings                    ...
  • Page 110: Safe-Op State

                      LED is turned ON. DeweSoft will set the Krypton slice/s in the OP state when you are in Measure Mode.       OP state       KRYPTON® V20-1 110 / 141    ...
  • Page 111: Mechanical Locking Of Modules

    KRYPTON®   TECHNICAL REFERENCE MANUAL       8.3. Mechanical locking of modules   KRYPTON modules can easily be stacked together. The mechanical lock mechanism is on the top and                    ...
  • Page 112: Mounting Plates

    8.4. Mounting plates   8.4.1. DS-MOUNT-K2   Aluminium mounting plate with click mechanism for mounting on the bottom side of KRYPTON   module. For detailed technical drawings please contact the Dewesoft team.    Fits to: KRYPTON single, KRYPTON dual, KRYPTON CPU  ...
  • Page 113: Ds-Mount2-K

    Aluminium mounting plate with click mechanism for mounting two KRYPTONs (bottom side to the   mounting plate) or KRYPTON CPU. The assembly can be afterward fitted to the top of the SIRIUS   module. For detailed technical drawings please contact the Dewesoft team.   ...
  • Page 114: Connection Overview

            requires a long power supply cable, you should consider using a thicker cable (e.g M10).      In the specification tables you can find a power consumption of each Krypton device and calculate        ...
  • Page 115 Device / Connector   Cable    Device / Connector   Description     EtherCAT connection from PC        to the KRYPTON EtherCAT   Ethernet RJ45 to LEMO 1T     device.   8pin female        ...
  • Page 116: Only Ethercat Devices

    TECHNICAL REFERENCE MANUAL       9.1. Only EtherCAT devices   When you only use DeweSoft EtherCAT devices (Krypton or Sirius EtherCAT), the connection is   straightforward via ECAT to ECAT cable.        A system with only ECAT devices (Krypton ONE, KRYPTON-8xTH, SIRIUSe, and KRYPTON-CPU)   ...
  • Page 117: Power Injector

    KRYPTON®   TECHNICAL REFERENCE MANUAL       9.2. Power Injector   The Power Injector box can be used to inject power to long EtherCAT measurement chains.   The Power Injector box needs an external power supply and must be connected directly between the  ...
  • Page 118   A system with Power Injector       List of required cables:   Function   DEWESoft order code   Power supply   PS-200-L1T8m   EtherCAT   EtherCAT to EtherCAT: L1T8m-L1T8f,   ECAT - PC connection: L1T8f-RJ45      ...
  • Page 119 ECAT power                                 injector is needed in the Krypton chain.        KRYPTON® V20-1 119 / 141    ...
  • Page 120: Power Junction

                        the Krypton devices are far away from the PC or a system and there is no power supply available (i.e. in a                ...
  • Page 121: Distributed System With Krypton One

    KRYPTON®   TECHNICAL REFERENCE MANUAL       9.4. Distributed system with Krypton ONE   Krypton One devices can be used in a remote area from other used devices connected with a                ...
  • Page 122: Ecat Sync Junction/Ecat Gps Junction

    Left system with Sync Junction - Right system with GPS EtherCAT junction       List of required cables:   Function   DEWESoft order code   Power supply   PS-120-L1T8m   EtherCAT   EtherCAT to EtherCAT: L1T8m-L1T8f,   ECAT - PC connection: L1T8f-RJ45  ...
  • Page 123 TECHNICAL REFERENCE MANUAL       The second purpose is to synchronize data between EtherCat data line (e.g KRYPTON line) with USB   data line (e.g. Sirius USB or DEWE-43-A).      Synchronizing data from USB and ECAT data lines with Sync junction  ...
  • Page 124: Connecting Sirius-R4 And Krypton Stg

        9.6. Connecting SIRIUS-R4 and Krypton STG    The ECAT sync junction is not required with IOLITE, SIRIUSe, R1, R2, R4, R8 or MINITAURs DAQ systems   when extended with EtherCAT devices, because the sync junction is already built into the systems.  ...
  • Page 125   Of course, other Krypton devices can be used, but you need to take into account that modules can only   run up to 100 Hz in the Soft-Sync mode. When a higher sample rate is chosen the synchronization won’t  ...
  • Page 126: Mixed System

    A mixed system with a built-in sync junction       List of required cables:   Function   DEWESoft order code   Power supply   PS-120-L1B2f   Supply Daisy chain   L1B2m-L1B2f   EtherCAT to EtherCAT: L1T8m-L1T8f,   Ethercat  ...
  • Page 127: Two Ethercat Lines

      Connection done with two Ethernet ports     List of required cables:   Function   DEWESoft order code   PS-120-L1T8m   Power supply   EtherCAT to EtherCAT: L1T8m-L1T8f,   Ethercat   ECAT - PC connection: L1T8f-RJ45   Synchronization  ...
  • Page 128: Use The Ds-Hube7 Junction

          Connection done with DS-HUBe7     List of required cables:   Function   DEWESoft order code   PS-120-L1T8m   Power supply   EtherCAT to EtherCAT: L1T8m-L1T8f,   Ethercat   ECAT - PC connection: L1T8f-RJ45      ...
  • Page 129: Appendix

    KRYPTON®   TECHNICAL REFERENCE MANUAL       10. Appendix   10.1. Glossary and abbreviations   This glossary includes explanations of some of the most important terms and abbreviations that are                  ...
  • Page 130                               signals in amplitude and frequency. DEWESoft® has a built-in visual control that makes FFT easy to use.   KRYPTON® V20-1 130 / 141    ...
  • Page 131 KRYPTON®   TECHNICAL REFERENCE MANUAL       FPGA   A field-programmable gate array (FPGA) is an integrated circuit designed to be configured by the                              ...
  • Page 132                   hardware.   This may refer to the operating system of a PC (Windows is required for DEWESoft®) or to the operating                    ...
  • Page 133         (usually PCs). SIRIUS® systems use a USB connection to connect to a PC.   Windows®   A PC operating system by Microsoft®. DEWESoft® will work on Windows® XP, Windows® Vista and          ...
  • Page 134: Warranty Information

            year, after system delivery.     11.2. Support   Dewesoft has a team of people ready to assist you if you have any questions or any technical difficulties                ...
  • Page 135: Copyright

                        technology name, the ® sign is not used. The Dewesoft triangle logo is a registered trademark but the ®                      ...
  • Page 136: Safety Instructions

            Dewesoft GmbH assumes no liability for the customer’s failure to comply with these requirements.      All accessories shown in this document are available as an option and will not be shipped as standard    ...
  • Page 137: Product End-Of-Life Handling

                Please find further information about recycling on the Dewesoft web site www.dewesoft.com       Restriction of Hazardous Substances   This product has been classified as Monitoring and Control equipment and is outside the scope of the  ...
  • Page 138                           verified by service-trained personnel. If necessary, return the product to Dewesoft sales and                           service office for service and repair to ensure that safety features are maintained.  ...
  • Page 139 KRYPTON®   TECHNICAL REFERENCE MANUAL       Use measurement leads or measurement accessories aligned with the specification of the                         ● system only. Fire hazard in case of overload!  ...
  • Page 140: Documentation Version

      13. Documentation version   Date   Doc-Version   Notes   [dd.mm.yyyy]   v20-1   15.06.2020   The NEW Krypton manual - Reworked and revised version   ● Added products:   ● KRYPTONi-1xCAN-FD   ○ KRYPTONi-8xLA   ○ Mounting plates  ...
  • Page 141: Previous Versions History

    Added KRYPTON-CPU   ● Added ECAT GPS Junction   ●       2.0.1   23.01.2019   Changed figure 4.7.3.1. KRYPTON Multichannel DIO modules:   ● connectors   --- THE END ---     KRYPTON® V20-1 141 / 141    ...

This manual is also suitable for:

Krypton one

Table of Contents

Save PDF