Download Print this page

Jantar LOKUS O Manual page 2

Advertisement

PROGRAMMING
The entire set-up procedure is carried out with the master card.
The master card cannot be replaced or duplicated. After
registration the master card should always be kept in a
secure place. You cannot change any setting without it and
neither can we. Keep that in mind when storing the master
card.
Programming Lokus with the master card
First connection to the power supply and registration of
the master card:
Turn the power supply on (2 beeps indicate power on) and
approach a card you wish to be the master card (3 beeps indicate
a successful registration). The first card registered becomes the
master card. All the other cards will be registered as users
(user cards).
Usage of master card:
If you hold the master card in front of the controller, every
two seconds a double beep is heard. The number of double
beeps indicates the programming function.
PROGRAMMING FUNCTIONS WITH MASTER CARD
Function
Description
1
Register or delete user cards
2
Pulse time/ Duration of active output or toggle
mode
3
Door status switch input/ time till pre-alarm
4
Pre-alarm and alarm/ duration of pre-alarm
5
Negate output
6
Delete a lost card
7
Delete a lost card
9
Switch to Wiegand 26-bit
13
Delete all
Function 1) User cards
Register or delete user cards.
Setup:
Approach the master card and remove it after 1 double beep.
Within a period of three seconds approach a user card. The user
card is now registered and with it, you can open output on the
controller. If the card has already been registered, it is now
deleted and its position is now empty. Next registered card will
take the first available position on the list or position of the
deleted card. To delete a lost user card, you must maintain a list
of registered cards, arranged in order of registrations (positions).
Function 2) Pulse time/ Duration of active output or toggle
mode
Set the duration of active output/ the time in which you can open
door or set output to toggle mode. Toggle mode means, if the
user card is registered, output will remain opened (if it was
closed) or closed (if it was open) till next registration.
Set the duration of active output:
Approach the master card and remove it after 2 double beeps.
The controller will start to beep every second. Each beep
indicates 1 second of active output. Duration of active output can
be max. 10 seconds. When you hear the required number of
beeps, approach a user card for confirmation.
Set toggle mode:
Approach the master card and remove it after 2 double beeps.
Approach a user card before the first beep. Toggle mode is
selected.
Black line
LOKUS O - Standalone controller
Function 3) Door status switch input
Set the time till pre-alarm / time in which the door can stay open,
without triggering the pre-alarm and consequently the alarm.
This function is used when the door status switch on el. strike is
connected to Input0/I0/wire 5 on the controller.
Setup:
Approach the master card and remove it after 3 double beeps.
The controller will start to beep every second. Each beep
indicates 1 second till pre-alarm. Duration of the time till pre-
alarm can be max. 10 seconds. When you hear the required
number of beeps, approach a user card for confirmation.
Function 4) Pre-alarm and alarm/ duration of pre-alarm
Set the pre-alarm time. This is the time in which the controller,
with short beeps, alerts you that the door was left open. If you
don't close the door in the pre-alarm time, the alarm will be
triggered and signaled with long beeps by the controller.
Setup:
Approach the master card and remove it after 4 double beeps.
The controller will start to beep every second. Each beep
indicates 1 second of the pre-alarm time. Duration of the pre-
alarm time can be max. 10 seconds. When you hear the required
number of beeps, approach a user card for confirmation.
Function 5) Negate / switch output state
This function is used, when you connect an electric strike or
electric magnet which needs power supply to remain in locked
state.
Setup:
Approach the master card and remove it after 5 double beeps.
Within a period of three seconds approach a user card for
confirmation. The output state will be switched from the current
one.
Function 6) Delete a lost card
Delete the next card on the list. Use this function if you lost a
card and you wish to delete it from the controller. In order to use
this function you must maintain a list of registered cards,
arranged by order of registrations so that you can find the card,
which was registered before the lost one.
Setup:
Approach the master card and remove it after 6 double beeps.
Within a period of three seconds approach the user card, which
was registered before the lost one. This will delete the lost user
card. Next registered card will take the position of a deleted card.
Function 7) Delete a lost card
Delete the previous card on the list. Use this function if you lost a
card and you wish to delete it from the controller. In order to use
this function you must maintain a list of registered cards so that
you can find the card, which was registered after the lost one.
Setup:
Approach the master card and remove it after 7 double beeps.
Within a period of three seconds approach the user card, which
was registered after the lost one. This will delete the lost user
card. Next registered card will take the position of a deleted card.
Function 9) Switch to Wiegand 26-bit
Switch between the controller and Wiegand 26-bit reader. When
you switch the controller on, it beeps twice in the controller mode
and once in the Wiegand 26-bit mode.
Switch to Wiegand 26-bit:
Approach the master card and remove it after 9 double beeps.
The controller will start to beep every second. Each beep presents
different function, which is selected with a user card.
1. beep – If you approach a user card after 1 beep, the controller
will switch to Wiegand 26-bit reader and will delete everything.
2. beep – If you approach a user card after 2 beeps, all data will
be deleted. The controller will be reset to default.