Advertisement

Quick Links

AEP-100
Installation Operation &
Maintenance Instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AEP-100 and is the answer not in the manual?

Questions and answers

Summary of Contents for JOMAR AEP-100

  • Page 1 AEP-100 Installation Operation & Maintenance Instructions...
  • Page 2: Table Of Contents

    Maintenance And Check Caution On Handling Trouble Shooting Option Pilot valve with output orifice Note: Information subject to change without notice. Jomar Valve ・ 7243 Miller Drive, Warren, MI 48092 ・ www.jomarvalve.com ・ phone: (586) 268-1220 ・ fax: (586) 979-8315 040215...
  • Page 3: General

    6 lbs. Ordering Model EP-100 is shipped standard with a steel mounting bracket. Note: Information subject to change without notice. Jomar Valve ・ 7243 Miller Drive, Warren, MI 48092 ・ www.jomarvalve.com ・ phone: (586) 268-1220 ・ fax: (586) 979-8315 040215...
  • Page 4: Inside View

    ⑫Actuator will stop at the point of force balance exerted by the input current signal and the feedback spring Note: Information subject to change without notice. Jomar Valve ・ 7243 Miller Drive, Warren, MI 48092 ・ www.jomarvalve.com ・ phone: (586) 268-1220 ・ fax: (586) 979-8315 040215...
  • Page 5: Block Diagram Of Aep-100

    Example of attaching to actuator Jomar provides a stamped steel bracket (above right) for mounting to the bottom of the positioner. However the PP-100 is drilled and tapped on the side for side mounting of a custom fabricated bracket (above left).
  • Page 6: Cam Attaching Procedure

    4. When using the double acting type as single acting type, plug either OUT1 or OUT2 and also remove the pressure gauge to close its connection. Note: Information subject to change without notice. Jomar Valve ・ 7243 Miller Drive, Warren, MI 48092 ・ www.jomarvalve.com ・ phone: (586) 268-1220 ・ fax: (586) 979-8315 040215...
  • Page 7: Electrical Wiring

    2. In case of Spring Actuator, check if it is set to standard pressure in Zero Point. If not, repeat zero adjustment. Note: Information subject to change without notice. Jomar Valve ・ 7243 Miller Drive, Warren, MI 48092 ・ www.jomarvalve.com ・ phone: (586) 268-1220 ・ fax: (586) 979-8315 040215...
  • Page 8: Span Adjustment

    4. If hunting occurs due to an actuator of small capacity, refer to description in Options on page 11. Note: Information subject to change without notice. Jomar Valve ・ 7243 Miller Drive, Warren, MI 48092 ・ www.jomarvalve.com ・ phone: (586) 268-1220 ・ fax: (586) 979-8315 040215...
  • Page 9: Maintenance And Check

    Wrong connection of OUT1 and OUT2 tubing Correct position of tubing by On/Off only Note: Information subject to change without notice. Jomar Valve ・ 7243 Miller Drive, Warren, MI 48092 ・ www.jomarvalve.com ・ phone: (586) 268-1220 ・ fax: (586) 979-8315 040215...
  • Page 10: Pilot Valve With Output Orifice

    4. If the hunting does not stop even after mounting the output orifice, please contact us. Note: Information subject to change without notice. Jomar Valve ・ 7243 Miller Drive, Warren, MI 48092 ・ www.jomarvalve.com ・ phone: (586) 268-1220 ・ fax: (586) 979-8315 040215...
  • Page 11 Note: Information subject to change without notice. Jomar Valve ・ 7243 Miller Drive, Warren, MI 48092 ・ www.jomarvalve.com ・ phone: (586) 268-1220 ・ fax: (586) 979-8315 040215...
  • Page 12 Note: Information subject to change without notice. Jomar Valve ・ 7243 Miller Drive, Warren, MI 48092 ・ www.jomarvalve.com ・ phone: (586) 268-1220 ・ fax: (586) 979-8315 040215...
  • Page 13 Note: Information subject to change without notice. Jomar Valve ・ 7243 Miller Drive, Warren, MI 48092 ・ www.jomarvalve.com ・ phone: (586) 268-1220 ・ fax: (586) 979-8315 040215...

Table of Contents