Dan Fogger/Mister
Additional Instructions for Cooling and Humidification
Use tee configuration with 2 Foggers or Super Foggers (4-way or cross is no longer
I
recommended because they cause high precipitation rates and prevent some of the water
from evaporating)
Recommended pressure is 60 PSI
I
Use high pressure LPD (Leak Prevention Device)
I
The foggers should be mounted as high as possible above the ground
I
The foggers should be installed perpendicular to the lateral line
I
Use anti-twist flexible PVC vinyl tube
I
Avoid contact between the droplets and any part of the greenhouse structure
I
Propagation and Germination
Using Dan Mister
Green Mist (7.9 GPH)
I
Green Mist Jr. (5.3 GPH)
I
Recommended working pressure 30 psi
I
Low pressure LPD
I
www.jainsusa.com
6
©2011 Jain Irrigation, Inc.