• All.assembly.and.electrical.installation.work.must.be. carried.out.according.to.our.assembly.instructions. Other types of indicators • Use the IO module/IO module smart only when it is Below.is.a.list.of.symbols.used.in.these.instructions.and. in.a.technically.sound.condition. their meanings: • Repair of the IO module/IO module smart is not • Items of text following this marker are found in lists.
Operating instructions SIEGENIA access control systems IO module/IO module smart instructions.that.are.enclosed.with.other.(optional). Warning notes used components. DANGER 1.11 Appropriate disposal The signal word "Danger" designates an immediately Electrical devices should not be disposed of as house- threatening danger. If this hazard is not prevented, it hold waste.
IO module/IO module smart e. g. for intercom system, provided by customer, and GENIUS A / B/ PANIC for.day/night.switchover.via.timer With the IO module/IO module smart, the GENIUS A • Communication.via.SI-BUS /B/ PANIC can be extended by the following inputs and outputs: •...
(see page 9). The.LEDs.switch.off.automatically.after. approx. 2 minutes if no further input on the IO module follows. f If the LEDs on the IO module are switched.off,.press.the.button. briefly.to.switch.on.the.LEDs. f The LED lights up magenta. f You are in the level 1 menu (see page 9).
Page 8
Operating instructions SIEGENIA access control systems IO module/IO module smart f Press.the.button.briefly.a.few. times.in.succession.to.retrieve. further level 1 menu items. f Every.press.of.a.button.is. acknowledged.by.an.acoustic. signal. f According to the menu item, another LED colour is displayed (see page 9) f Hold.down.the.menu.button.3. seconds to select a level 2 menu item.
Operating instructions SIEGENIA access control systems IO module/IO module smart Adjustable functions on IO module in combination with GENIUS A/B Connection diagram with GENIUS A/B Menu structure IO module Out 1 - 3 Volume of Device System Out 1 Out 2...
Operating instructions SIEGENIA access control systems IO module/IO module smart Some menu items under „System services“ and „WIFI“ can only be carried with a WIFI-capable device that is integrated in the SI-BUS system (e. g. IO.module.smart,.SIEGENIA.ACS)..The.menu.items.are.always.visible.and.no.error.message.will.appear.if.the.function.cannot.be.carried.out. The "System services" menu can be retrieved up to 10 minutes following the system start. The "WIFI" menu can be retrieved up to 5 minutes...
Operating instructions SIEGENIA access control systems IO module/IO module smart 5.3.2 Feedback function for Out 1 LED colour in Alternating LED colours Function Description level 1 in level 2 Yellow/White Door closed and locked* Day mode = door closed Yellow/off...
Operating instructions SIEGENIA access control systems IO module/IO module smart 5.3.4 Feedback functions for Out 3 LED colour in Alternating LED colours Function Description level 1 in level 2 Dark blue/White Door locked / unlocked Dark.blue/off Door open / close...
Operating instructions SIEGENIA access control systems IO module/IO module smart 5.3.6 Functions for In 1 The.potential-free.input.contacts.in.1,.e..g..for.intercom.system,.provided.by.customer,.and.for.day/night.switcho- ver.can.be.configured.via.timer. LED colour in Alternating LED colours Function Description level 1 in level 2 Vanilla/White Switchover day/night mode* Vanilla/off Open Vanilla/Orange Opening impulse Vanilla/Red Combination.day/night/opening.procedure.impulse...
Separate devices Light red/Orange Unblock access control unit Light red/Red Reset.to.factory.settings Bright red Light red/Turquoise Switch on WIFI (only for IO module smart) Bright red/Violet Switch.off.WIFI.(only.for.IO.module.smart) 5.3.10 WIFI (only for IO module smart) LED colour in Alternating LED colours Command...
Operating instructions SIEGENIA access control systems IO module/IO module smart Adjustable functions on IO module in combination with third-party drives Connection diagram with WIFI via SIEGENIA ACS Connection diagram with WIFI via IO module smart Third-party drive Third-party drive V V V V V V V V V.ADJ...
Operating instructions SIEGENIA access control systems IO module/IO module smart Functions 6.2.1 Volume of the buzzer The.buzzer.delivers.the.acoustic.feedback.of.the.menu.navigation.or.in.case.of.malfunction.. The.volume.for.the.feedback.of.the.opening.process.is.adjustable.in.five.stages.from.0.%.to.100.%. The.volume.for.the.feedback.of.malfunction.is.preset. LED colour in Alternating LED colours Description level 1 in level 2 Magenta/White Volume: 100 % Magenta/off Volume: 75 % Magenta/Orange...
Operating instructions SIEGENIA access control systems IO module/IO module smart 6.2.3 Functions switching relay Out 2 The.relay.Out.2.switches.when.IN.1.or.IN.2.receive.an.impulse.(e..g..from.a.button.etc.). LED colour in Alternating LED colours Description level 1 in level 2 Light green/White Switches for 1 second Light.green/off Switches for 3 seconds...
Operating instructions SIEGENIA access control systems IO module/IO module smart 6.2.6 Functions for In 1 The.input.IN.1.receives.an.impulse.(e..g..a.button).to.switch.OUT.1.to.3). LED colour in Alternating LED colours Description level 1 in level 2 Vanilla/White Switches OUT 1 Vanilla/off Switches OUT 2 Vanilla/Orange Switches OUT 3...
Separate devices Light red/Orange Unblock access control unit Light red/Red Reset.to.factory.settings Bright red Light red/Turquoise Switch on WIFI (only for IO module smart) Bright red/Violet Switch.off.WIFI.(only.for.IO.module.smart) 6.2.10 WIFI (only for IO module smart) LED colour in Alternating LED colours Command...