Download Print this page

Sealey SA661 Instructions page 3

Air needle scaler composite

Advertisement

5. MAINTENANCE
WARNING! Disconnect needle scaler from air supply before servicing or performing
maintenance. Replace or repair damaged parts. Use genuine parts only.
Unauthorised parts may be dangerous and will invalidate the warranty.
5.1.
To replace the needles, unscrew the scaling head from the barrel sleeve. Replace the
appropriate needles. Use only genuine Sealey needles. Screw the scaling head onto the
barrel sleeve and tighten.
5.2.
Lubricate the needle scaler daily with a few drops of Sealey air tool oil dripped into the air
inlet.
5.3.
Clean the needle scaler after use.
5.4.
Loss of power or erratic action may be due to the following:
a) Excessive drain on the air line. Moisture or restriction in the air pipe. Incorrect size or type
of hose connectors. To remedy check the air supply and follow instructions in Section 3.
b) Grit or gum deposits in the needle scaler may also reduce performance. Flush the
needle scaler out with gum solvent oil or an equal mixture of SAE10 oil and paraffin.
Allow to dry before use.
5.5.
For a full service contact your local Sealey service agent.
5.6.
When not in use, disconnect from air supply, clean needle scaler and store in a safe, dry,
childproof location.
The SA661, when operated in accordance with these instructions and tested in accordance with BS EN ISO
28927-9:2009 results in the following vibration emission declared in accordance with BS EN12096:1996.
Measured vibration emission value: ......5.7m/s² Uncertainty: ............... 2.28m/s²
These values are suitable for comparison with emission levels of other tools that have been subject
to the same test.
This tool may cause hand-arm vibration syndrome if its use is inadequately managed.
Recommended Measures to reduce risk of hand-arm vibration syndrome:
This tool should not be used by an individual regularly for more than 188 minutes in any 8 hour period.
This duration of use should be reduced if the individual is exposed to hand-arm vibration from other sources.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
Risk of Hand Arm Vibration Injury.
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
Original Language Version
www.sealey.co.uk
01284 757500
Web
01284 703534
sales@sealey.co.uk
email
SA661 Issue: 1 - 01/09/11

Advertisement

loading