The Castle GA690 electronic barometer can be used to accurately display the atmospheric pressure at your
location.
The barometer measures the absolute pressure of the ambient atmosphere. The pressure measured is not
necessarily the same pressure as would be published on weather forecasts etc as this figure is normally the
pressure taken at sea level. The barometer can be set to display the figure at sea level by using the S.L (sea level
correction) function if your altitude is known.
Powering the barometer on:
To turn the barometer on simply press and release the ON/OFF key once. The barometer should then turn on
and perform a segment test on the display. To turn the barometer off simply press and release the ON/OFF key
once more.
Configuration of the barometer:
1.
Auto power off (P.of) - It is possible to set the barometer to automatically turn off after a preset time off
between 1 and 120 minutes:
I.
Press and hold the MODE key whilst powering on until 'P.of' is displayed
II.
Press the MODE and ZERO keys to scroll up and down in minutes to select your desired power off
time. It is also possible to have the barometer to stay permanently on by scroll down using the
MODE key until 'off' is displayed. This disables the auto power off function.
III.
Confirm your selection by pressing the ON/OFF key, 'uni' should then appear on the display.
2.
Display unit (uni) – It is possible to change the units that the barometer displays in between hectoPascal
(hPA) and mmHg (nHg). Please note that 1hPA = 1mbar.
I.
Follow instructions for auto power off above.
II.
Press the MODE and Zero keys to scroll between 'hPA' and 'nHg'.
III.
Confirm your selection by pressing the ON/OFF key, 'S.L' should then appear on the display.
3.
Sea level correction (S.L)* – It is possible to correct the measured pressure back to the pressure value at
sea level (zero altitude).
I.
Follow instructions for display units above.
II.
Press the MODE and ZERO keys to turn the sea level correction function 'on' or 'off'.
III.
Confirm your selection by pressing the ON/OFF key. 'Alt' should then appear on the display if 'on'
was selected or the barometer will restart with if 'off' is selected.
*Please note that this feature should be turned off when used for the calibration of a sound level meter
4.
Altitude reading (Alt)* – If using the sea level correction function then you must set your altitude level in
metres. It is possible to enter an altitude of between 1m and 1999m.
I.
Follow instructions for sea level correction above.
II.
Press the MODE and ZERO keys to scroll up and down in metres to select your current altitude.
III.
Confirm your selection by pressing the ON/OFF key, The barometer should now restart.
Please note that if during the configuration no key is pressed within 20 seconds then the configuration will be
aborted.
*Please note that this feature should be turned off when used for the calibration of a sound level meter
Castle GA690 Electronic Barometer
Need help?
Do you have a question about the GA690 and is the answer not in the manual?
Questions and answers