Metal Fab MLK Installation And Maintenance Instructions

Metal Fab MLK Installation And Maintenance Instructions

Chimney lining and vent connector systems

Advertisement

MODEL MLK & MLKE
CHIMNEY LINING AND
VENT CONNECTOR SYSTEMS
MODEL MLK
Flex Aluminum Chimney Liner Kit
Kit Includes:
Gas Liner
Mortar Guard
Rain Cap
Factory Attached Couplings
Flashing
Pull Bar
Storm Collar
CAUTION:
Metal-Fab gas vent relining systems have been designed to properly vent Category I gas-burning appliances only. Appliances
burning solid or liquid fuels or Category II, III, or IV furnaces are not to be connected to this lining system.
This Metal-Fab lining system is intended for use as a masonry chimney liner, factory-built chimney liner, or Type-B gas vent liner.
Metal-Fab liners are intended to be installed in accordance with the standard for chimneys, fireplaces, vents and solid fuel burning
appliances, per NFPA 211.
NOTE: When an existing gas, oil, or wood burning appliance is being replaced by a gas burning appliance, the existing
chimney can be used as a conduit for a flexible aluminum liner. The inside of the existing system must be of sufficient
diameter to allow the liner to pass through and the existing system must have been properly installed (See Manufacturer's
instructions for details).
Although this product may be installed in an unenclosed space between the appliance and the masonry chimney,
factory-built chimney, or Type-B gas vent, it must not pass through any combustible structure such as a wall, ceiling,
floor, attic space, or crawl space. Contact local building or fire officials about restrictions and installations in your area.
Metal Fab gas vent relining systems have been designed to properly vent gas burning appliances. Substituting other
parts not identified within these instructions may pose an unsafe installation. Acceptance of the lining system is void if
the installation instructions are not followed.
Wall penetration assemblies are not to be located directly behind a heating appliance.
The chimney liner must not be sized less than that specified in the appliance manufacturers instructions. Correct sizing
of liner is critical for venting of low temperature flue products in geographical areas experiencing sustained low ambient
temperatures.
Prior to installing a liner system in a masonry chimney, the chimney is to be thoroughly cleaned and inspected. Check
for cracked, loose or missing bricks, mortar or other materials that could inhibit correct liner installation. Repair chimney
as required. Removal of all tar glazed creosote is a must prior to installation of chimney liner. Verify the air space
clearances between the masonry chimney exterior and combustible materials is in accordance with applicable building
code requirements.
Prior to installing linear system in a factory-built chimney or Type-B gas vent, the chimney is to be thoroughly cleaned
and inspected. Check for structural defects that all parts (such as support, radiation shield, firestop, etc.) specified by
the chimney or vent manufacturer. Repair chimney or vent as required. Removal of all tar glazed creosote is a must
prior to installation of chimney liner. Verify that the airspace clearances between chimney or vent exterior casing and
combustible material is in accordance with the installation instructions.
Wear gloves when handling metal parts to avoid personal injury.
METAL-FAB INC. • P.O. BOX 1138, WICHITA, KANSAS 67201 • (316) 943-2351
Installation AND MAINTENANCE
INSTRUCTIONS
MODEL MLKE
Flex Aluminum Chimney Liner Kit
Kit Includes:
Gas Liner
Mortar Guard
Rain Cap
Hardware Package (9ea. Self Tapping Screws)
Flashing
Coupling (5.5" Dia. Only)
Listing No. MH 17528
Tested to UL 1777 & ULC 3635
(For Chimney Liners)
Listing No. MH 25730
(For Vent Connectors)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MLK and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Metal Fab MLK

  • Page 1 Contact local building or fire officials about restrictions and installations in your area. Metal Fab gas vent relining systems have been designed to properly vent gas burning appliances. Substituting other parts not identified within these instructions may pose an unsafe installation. Acceptance of the lining system is void if the installation instructions are not followed.
  • Page 2 GENERAL: MLK and MLKE gas vent lining systems are listed by UL & ULC for INSTALLATION: installation at zero clearance to the inside masonry surface and with...
  • Page 3 (NOT INCLUDED WITH KIT) bends greater than 90 degrees (See FIG. 6). FIG. 6 FLASHING (MLK ONLY) INTERIOR WALL MLK and MLKE: If the flex liner is to exit the sidewall of a masonry chimney, must pass through mortar guard (See FIG.
  • Page 4 Attach the inlet end of the flexible liner to either single wall pipe or B-Vent pipe that is serving as the connector between a single gas MLK/MLKE: For tall chimney installations where more than one length of appliance and the flex liner (See FIG. 7).