  • Page 1 AirSim User Manual Version 4.1...
  • Page 2: Table Of Contents

    Table of Contents A I R S I M R A N G E Introduction Introducing the AirSim range Quick set up guides AirSim Standard, Multi & Bronchi AirSim Advance AirSim Advance Bronchi AirSim Advance Crico AirSim Advance Traci AirSim Advance Larynx AirSim Baby AirSim Pierre Robin AirSim Child...
  • Page 3: Introduction

    Introduction Designed and produced by TruCorp, the AirSim range brings highly realistic and fully functional airway training systems to the market. The main and most important component of the AirSim range is the unique AirSim airway. This is a faithful reproduction of the human airway anatomy and as such is invaluable as a training aid to facilitate the learning and development of airway management skills for all health professionals.
  • Page 4: Introducing The Airsim Range

    Introducing the AirSim product range AirSim Standard The AirSim Standard is uniquely constructed to allow realistic feedback during airway management procedures and provides true, anatomically correct and visually accurate internal features. The neck construction allows the head to be moved and secured in a number of positions.
  • Page 5 AirSim Multi The AirSim Multi contains the key features of the AirSim Standard with the addition of a nasal passage and a chin. The AirSim Multi facilitates training on nasal procedures as well as bag and mask ventilation techniques. The nasal passage has been developed in a manner similar to the main airway.
  • Page 6 AirSim Bronchi The AirSim Bronchi is the latest product addition to the AirSim family, providing anatomically correct detail down to the fourth generation bronchi. The AirSim Bronchi provides exceptional detail in both internal and external features; made possible through a combination of cutting edge moulding technology and carefully handcrafted processes.
  • Page 7: Airsim Advance

    AirSim Advance The AirSim Advance is the most recent addition to the AirSim family. The advance model still maintains the features of the AirSim Multi unit, however for added realism a head and neck skin has been added. It is lightweight and portability, and maintains the unique features such as the AirSim airway and nasal passage.
  • Page 8: Airsim Advance Bronchi

    Bronchi features. Additional lung bags can be attached onto the bronchioles to highlight successful bag mask ventilation but please ask your distributor representative or Trucorp for this feature if applicable as this is not a product feature that comes as standard with the Bronchi range of models.
  • Page 9: Airsim Advance Crico

    AirSim Advance Crico The AirSim Advance Crico is the newest addition to the AirSim family. The Advance Crico model still maintains the features of the AirSim Advance unit, however for added realism during needle/surgical Cricothyroidotomy the neck area has been manipulated to contain the anatomical features which are highlighted during a Cricothyroidotomy procedure.
  • Page 10: Airsim Advance Traci

    AirSim Advance Traci The AirSim Advance Traci is an innovative addition to the AirSim family. The Advance Traci model has the added benefit of a new design that allows for greater realism. It has anatomically correct laryngeal cartilages and palpable tracheal rings to provide positive user feedback.
  • Page 11: Airsim Advance Larynx

    It also comes with Trucorp’s new specially developed “TLT” material vocal cords which highlight a range of cancers and polyps for the use of training in CO2 laser removal techniques.
  • Page 12: Airsim Baby

    AirSim Baby The AirSim Baby is the latest addition to the AirSim Family. Uniquely constructed to allow realistic feedback during airway management procedures and provides true, anatomically correct and visually accurate internal features. AirSim Baby has a realistic anatomy that enables basic and advanced paediatric airway management.
  • Page 13: Airsim Pierre Robin

    It is an anatomically correct model with very realistic features to allow for high fidelity training of difficult airway management. True to Trucorp’s well known branding the model is presented on a lightweight and sturdy frame. The model comes shipped with its own lungs to demonstrate correct tube placement.
  • Page 14: Airsim Child

    Realistic and true internal anatomical features allow for an efficient and successful demonstration of all paediatric videolaryngoscopes. True to Trucorp’s products this model is presented in an aesthetically pleasing lightweight frame with lung bags included to illustrate correct tube placement.
  • Page 15 For more difficult airway management scenarios the head can be fixed in a more forward position. Using Trucorp’s silicone lubricant ensure that the internal airway is well lubricated including the tongue, hard palate, back of the mouth and epiglottis. If appropriate ensure that the nasal passage is lubricated.
  • Page 16 Increasing the amount of air will create a more difficult airway management scenario. Using Trucorp’s silicone lubricant ensure that the internal airway and Nasal passage are well lubricated. Ensure that all airway devices are prepared to the manufactures recommendations and instructions.
  • Page 17 Removing the AirSim Advance and AirSim Advance Bronchi head from base The head can be detached from the base by removing the 3 bolts from the underside of the base as shown below. The head can be reattached to the base by attaching screws in positions 1 & 2 before attaching 3.
  • Page 18 To ensure a completed fully functional neck skin, all velcro locations must be attached to the skin. Using Trucorp’s silicone lubricant ensure that the internal airway and the nasal passage is well lubricated. Ensure that all airway devices are prepared to the manufactures...
  • Page 19 Trucorp provide the following spare parts for the AirSim Advance Crico. These can be ordered while purchasing using the following codes;...
  • Page 20 To ensure a completed fully functional neck skin, all velcro locations must be attached to the skin. Using Trucorp’s silicone lubricant ensure that the internal airway and the nasal passage is well lubricated. Ensure that all airway devices are prepared to the manufactures recommendations and instructions.
  • Page 21 Trucorp provide the following spare parts for the AirSim Advance Traci. These can be ordered while purchasing using the following codes;...
  • Page 22 Quick set up guide for AirSim Advance Larynx 1. Remove AirSim Advance Larynx from the black carrier case, with blue bag and plastic connector. 2. Connect one end of the plastic connector to the open section of the left Bronchi on AirSim airway if you carrying out airway management on the model.
  • Page 23 11. Full care is needed when using the laser on the model and that only the vocal cord area with the TLT material is used for ablation. 12. Using Trucorp’s silicone lubricant ensure that the internal airway and Nasal passage is well lubricated if used for airway management. (If applicable) 13.
  • Page 24 Trucorp provide the following vocal cord inserts and parts for the AirSim Advance Larynx. These can be ordered while purchasing using the following codes; For laser procedures. LVC-C1 -Cancer 1 – Single small cancer on vocal cords LVC-P2- Polyp 2 - Two small polyps opposing on the vocal cords LVC-C2 –...
  • Page 25 Connect both ends of the lung bags to the open sections of the bronchi Using Trucorp’s silicone lubricant ensure that the internal airway and Nasal passages are well lubricated. Ensure that all airway devices are prepared to the manufactures recommendations and instructions.
  • Page 26 Remove the AirSim Child from the black carrier case, with blue lung Connect both ends of the lung bags to the open sections of the bronchi Using Trucorp’s silicone lubricant ensure that the internal airway and Nasal passage are well lubricated.
  • Page 27: Airway Management

     Tracheal Tubes  Fibreoptic Laryngoscopes  Needle Cricothyroidotomy Systems TruCorp recommend the following equipment sizes for optimal performance:  8.0-9.0 mm ID for oral intubation  Size 3 and 4 for LMA laryngeal masks (similar respective sizes for other supraglottic devices)
  • Page 28 The AirSim Bronchi can also be used in a similar manner to the AirSim Multi and can cover an extensive range of training requirements. Trucorp recommend the following equipment sizes for optimal performance:  7.0-7.5 mm ID for nasal intubation ...
  • Page 29  Fibreoptic bronchoscopic equipment.  Single and double lumen tubes and bronchial blockers.  Specialised bronchial stents. TruCorp recommend the following equipment sizes for optimal performance:  7.0-7.5 mm ID for nasal intubation  8.0-9.0 mm ID for oral intubation ...
  • Page 30  Naso–tracheal intubation  Awake Fibreoptic examination  Bag & mask ventilation techniques. TruCorp recommend the following equipment sizes for optimal performance:  7.0-7.5 mm ID for nasal intubation  8.0-9.0 mm ID for oral intubation  Size 3 and 4 for LMA laryngeal masks...
  • Page 31  Positive pressure ventilation.  Bag & mask ventilation techniques.  Endotracheal intubations. TruCorp recommend the following equipment sizes for optimal performance:  Size 3.5 - 4 tracheal tubes  Size 1 for LMA laryngeal masks (similar respective sizes for other supraglottic devices) ...
  • Page 32: Care And Maintenance

    palpation and then insert the needle and/or the dilators. When the needle or dilators are removed the material reverts to its original size. We also supply spare sealing tape for further use. Please note that the use of a scalpel or any sharp blade prior to performing Cricothyroidotomy on the AirSim Standard, Multi or Bronchi is NOT required.
  • Page 33: Warranty

    If the unit should malfunction it must be returned to the factory for evaluation. Upon examination by TruCorp, if the unit is found to be defective it will be repaired or replaced at no charge. However this warranty is VOID, if the unit...