Fluidcontrol
Temperature sensor/switch
TF, TS, Thermolog
Installation and Operation Instructions
Original instructions
BE140006
Bühler Technologies GmbH, Harkortstr. 29, D-40880 Ratingen
11/2019
Tel. +49 (0) 21 02 / 49 89-0, Fax: +49 (0) 21 02 / 49 89-20
E-Mail: fluidcontrol@buehler-technologies.com
Internet: www.buehler-technologies.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TF Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Buhler TF Series

  • Page 1 Fluidcontrol Temperature sensor/switch TF, TS, Thermolog Installation and Operation Instructions Original instructions BE140006 Bühler Technologies GmbH, Harkortstr. 29, D-40880 Ratingen 11/2019 Tel. +49 (0) 21 02 / 49 89-0, Fax: +49 (0) 21 02 / 49 89-20 E-Mail: fluidcontrol@buehler-technologies.com Internet: www.buehler-technologies.com...
  • Page 2 Bühler Technologies GmbH, Harkortstr. 29, D-40880 Ratingen Tel. +49 (0) 21 02 / 49 89-0, Fax: +49 (0) 21 02 / 49 89-20 Internet: www.buehler-technologies.com E-Mail: fluidcontrol@buehler-technologies.com Read this instruction carefully prior to installation and/or use. Pay at- tention particularly to all advises and safety instructions to prevent in- juries.
  • Page 3: Table Of Contents

    TF, TS, Thermolog Contents Introduction.............................................  2 Intended Use.........................................  2 Model key.......................................... 2 Safety instructions.........................................  4 Important advice ......................................... 4 General hazard warnings .................................... 5 Transport and storage ........................................ 6 4 Setup and Connection ........................................ 7 Operation and control ........................................ 8 TF-M-Pt100/TF-E-Pt100/TF-M-Pt100-VAL Temperature Sensor ...................... 8 TSM/TSK/TSA Bi-Metal Temperature Switch .............................. 8 Thermolog MK2/EK2 Temperature Sensor with 4-20mA Output...................... 8 6 Maintenance and repair ...................................... 9...
  • Page 4: Introduction

    TF, TS, Thermolog 1 Introduction 1.1 Intended Use Temperature sensors can be used to monitor the temperature of a fluid within a tank. These operating instructions describe several temperature switches / sensors types in one, as many descriptions identical or similar.
  • Page 5 TF, TS, Thermolog Typenschlüssel für Temperaturfühler TSM/TSE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -...
  • Page 6: Safety Instructions

    TF, TS, Thermolog 2 Safety instructions 2.1 Important advice Operation of the device is only valid if: – the product is used under the conditions described in the installation- and operation instruction, the intended application according to the type plate and the intended use. In case of unauthorized modifications done by the user Bühler Technolo- gies GmbH can not be held responsible for any damage, –...
  • Page 7: General Hazard Warnings

    TF, TS, Thermolog 2.2 General hazard warnings The equipment must be installed by a professional familiar with the safety requirements and risks. Be sure to observe the safety regulations and generally applicable rules of technology relevant for the installation site. Prevent malfunctions and avoid personal injuries and property damage.
  • Page 8: Transport And Storage

    TF, TS, Thermolog 3 Transport and storage Only transport the product inside the original packaging or a suitable alternative. The equipment must be protected from moisture and heat when not in use. It must be stored in a covered, dry, dust-free room at room temperature.
  • Page 9: Setup And Connection

    TF, TS, Thermolog 4 Setup and Connection DANGER Toxic, corrosive gasses The sample gas can be harmful to the health if inhaled or on contact. a) Ensure harmful gases are discharged safely. b) Switch off the gas supply before performing maintenance and repairs, and flush the gas lines with air.
  • Page 10: Operation And Control

    TF, TS, Thermolog 5 Operation and control DANGER Electric voltage Risk of electric shock a) Disconnect the unit from the mains when performing any maintenance. b) Secure the equipment from accidental restarting. c) The unit may only be maintained and opened by instructed, competent personnel. The pin assignment for the respective models are listed in chapter Pin Assignment [>...
  • Page 11: Maintenance And Repair

    TF, TS, Thermolog 6 Maintenance and repair NOTICE Always observe the applicable safety and operating regulations when performing any type of maintenance. If the devices are mounted according to the instructions, a maintenance is not necessary. BE140006 ◦ 11/2019 Bühler Technologies GmbH...
  • Page 12: Service And Repair

    TF, TS, Thermolog 7 Service and repair This chapter contains information on troubleshooting and correction should an error occur during operation. Repairs to the unit must be performed by Bühler authorised personnel. Please contact our Service Department with any questions: Tel.: +49-(0)2102-498955 or your agent If the equipment is not functioning properly after correcting any malfunctions and switching on the power, it must be inspected by the manufacturer.
  • Page 13: Disposal

    TF, TS, Thermolog 8 Disposal Dispose of parts so as not to endanger the health or environment. Follow the laws in the country of use for disposing of elec- tronic components and devices during disposal. BE140006 ◦ 11/2019 Bühler Technologies GmbH...
  • Page 14: Appendix

    TF, TS, Thermolog 9 Appendix 9.1 Technical data 9.1.1 TF and Thermolog Temperature Sensor TF-M-PT100 TF-E-PT100 THERMOLOG MK2 THERMOLOG EK2 TF-M-PT100-VAL Screw-in thread: G ½ G ½ G ½ G ½ G ½ Max. pressure 5 bar 10 bar 5 bar 10 bar 1 bar Operating temperature...
  • Page 15: Pin Assignment

    TF, TS, Thermolog 9.2 Pin Assignment 9.2.1 TF-M-Pt100/TF-E-Pf100/TF-M-Pt100-VAL Temperature Sensor With M3 plug per DIN With GS4 plug With M12 plug EN 175301-803 2 lead 3 lead 4 lead 9.2.2 Thermolog MK2/EK2 Temperature Sensor with 4-20 mA Output With M3 plug per DIN EN 175301-803 With M12 plug 9.2.3 TSA/TÖA Bi-Metal Temperature Switch With M3 plug per DIN EN 175301-803...
  • Page 16: Tsm/Tsk Bi-Metal Temperature Switch

    TF, TS, Thermolog 9.2.4 TSM/TSK Bi-Metal Temperature Switch NOTICE The designation T1 indicates the temperature contact with the low switching temperat- ure. The designation T2 indicates the temperature contact with the higher switching temper- ature. With M3 plug per DIN EN 175301-803 With M12 plug Bühler Technologies GmbH BE140006 ◦...
  • Page 17: Attached Documents

    TF, TS, Thermolog 10 Attached documents – Declarations of conformity: KX140002, KX110021 – RMA decontamination statement BE140006 ◦ 11/2019 Bühler Technologies GmbH...
  • Page 20 RMA-Formular und Erklärung über Dekontaminierung RMA-Form and explanation for decontamination RMA-Nr./ RMA-No. Die RMA-Nummer bekommen Sie von Ihrem Ansprechpartner im Vertrieb oder Service./ You may obtain the RMA number from your sales or service representative. Zu diesem Rücksendeschein gehört eine Dekontaminierungserklärung. Die gesetzlichen Vorschriften schreiben vor, dass Sie uns diese Dekontaminierungserklärung ausgefüllt und unterschrieben zurücksenden müssen.
  • Page 21 Dekontaminierungserklärung DE000011 Bühler Technologies GmbH, Harkortstr. 29, D-40880 Ratingen 01/2019 Tel. +49 (0) 21 02 / 49 89-0, Fax: +49 (0) 21 02 / 49 89-20 E-Mail: service@buehler-technologies.com Internet: www.buehler-technologies.com...

Table of Contents