  • Page 1 GATE BOLT Item 28720 MOTOR DEAD-BOLT INSTALLATION AND USE MANUAL...
  • Page 3: Technical Data

    TECHNICAL DATA Power 12 - 24 Vac 12 (13,8 min.) - 24 Vdc Not polarized wires 1,5mm ⊘ minimum Max current consumption 5A at 15Vdc with bolt under load pressure Default timing 2 sec. T1 - Time adjustment between 0-5 seconds from re-locking after door opening Default timing 5 sec...
  • Page 4 TIME ADJUSTEMENT MODE OF OPERATION and TIME ADJUSTEMENT are managed by means of a small round magnet supplied in the fixing accessories bag. These settings can be done without the aluminum cover ( drawing A) or with aluminum cover on (drawing B) positiong the magnet at 87mm from the top These setting must be done locating the round magnet as from the drawing below Magnet Magnet...
  • Page 5 HOW TO SELECT MODE OF OPERATION Set the magnet as indicated in the above drawing, before powering the Legion Automatic ( default ) Blue LED 1 flash 4 seconds Step by step Blue LED 2 flashes 4 seconds Automatic, fail safe Blue LED 3 flashes 4 seconds Step by step, fail safe...
  • Page 6 TIMING T2 KEEP THE BOLT POWERED WITH BOLT TOTALLY OUT (opening command not activated and red LED on). KEEP THE DOOR SENSOR IN CLOSE OSITION Checking selected timing – bring near the round magnet as form above • drawing for a second. Blue LED is lit on and the Red LED starts flashing to represent the time selected according to the below chart Setting the timing - bring near the round magnet as from above drawing and •...
  • Page 7 DIMENSIONS...
  • Page 8 ACCESSORIES FIXING PLATE ITEM 02287 Fix the plate 02287 in position and secure the Legion into the plate using provided screws. Wires passage FiXING PLATE HOLES FIXING PLATE HOLES...
  • Page 9 FLOOR STRIKING PLATE 02290 TOP AND SIDEWAYS STRIKING PLATE Code 02291 - Silver Code 02291N - Black SPACERS Code 02292 - 3 mm Code 02923 – 1 mm...
  • Page 10: Door Sensor

    DOOR SENSOR Code 02221 Code 02223 Armored rose Code 02250LG For mounting with fixing plate code 02287...
  • Page 11 EURO-PROFILE CYLINDER Inside Outside Half cylinder Legion 40 mm 10 mm Double cylinder Legion 40 mm Door thickness + 15 mm Double cylinder Legion + fixing 40 mm Door thickness + 18 mm plate Double cylinder Legion + fixing 40mm Door thickness + 30 mm plate + armored rose...
  • Page 12 SCHEMES Power in – not polarised 12 (13,8) - 24 Vac - Vdc Opening command N.O, 0V Remote Door sensor Alarm Opening command with direct voltage (i.e. by interphone ) LED lit Bolt open LED lit Bolt close LED flashing Engine failed LED flashing slowly Warm up on...
  • Page 13: Electrical Connection

    ELECTRICAL CONNECTION 12 (13,8) – 24 Vac / Vdc (not polarised) Power in Opening command 0V Door sensor Opening command with tension Alarm / Trouble U.P.C AP: Opening command by dry contact; continuous input keeps the bolt open all time – do not give power on this input APT: Opening command with 12-24Vac-dc AL: Open collector output for alarm signal and/or bolt trouble.
  • Page 14 A double magnetic sensor is housed inside the electronic circuit to cover both sides of the lock Door sensor item 02221 item 02223 A and B: These are housed-in magnetic readers. To be used they must be paired with magnets C (permanent polarized magnets) D and E: These are remote door sensor that can be used instead of the housed-in reader A and B.
  • Page 15 FAIL SAFE CIRCUIT – to be ordered separately This PCB is made to give a last opening command in case of power failure. The LEGION Bolt will stay open, even when power is back, until a new opening command is given. When this function is activated, the opening command must be a 0V (dry contact) Power in Input...
  • Page 16 OPERA s.r.l. – Via Portogallo 43 – 41122 Modena (MO) – Italy Tel. +39 059 451708 – Fax +39 059 451697 Internet: e-mail: info@opera-access.it www.opera-italy.com REV. 10/19...