Advertisement

User Manual
Profino Revolution Plus
Ref. 6711
PATENT PENDING
SW Version 1.6.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Johansson Profino Revolution Plus and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Unitron Johansson Profino Revolution Plus

  • Page 1 User Manual Profino Revolution Plus Ref. 6711 PATENT PENDING SW Version 1.6.0...
  • Page 2: Table Of Contents

    No part of this manual may be copied, reproduced, transmitted, transcribed or translated into any language without permission. Unitron reserves the right to change the specifications of the hardware and software described in these manuals at any time. Unitron cannot be held liable for any damages resulting from the use of this product. Specifications are subject to change without notice.
  • Page 3: Introduction

    1.1. Product description The Johansson Profino Revolution Plus is an easy to use programmable filter amplifier and convertor for terrestrial signals. The module optimizes terrestrial VHF/UHF and FM signals from multiple inputs with the goal to provide high quality images on your TV screen. The state-of-...
  • Page 4: Hardware Installation

    PROFINO REVOLUTION PLUS (REF. 6711) 1.4. Hardware installation 1: T IGURE OP VIEW OF PRODUCT 1.5. Mounting the Profino Revolution Plus • Important: Mount the module vertically to a wall in a well-ventilated room and leave a minimum space of 15 cm around the product to guarantee a maximum ventilation of the product •...
  • Page 5: Configuring The Profino Revolution Plus

    PROFINO REVOLUTION PLUS (REF. 6711) 1.6. Configuring the Profino Revolution Plus AVIGATING THROUGH THE MENU Use the Johansson rotary/push button to navigate through the menu. This is very straightforward and simple. The table below shows how the rotary/push should be used: Push the button 2s to enter the basic configuration.
  • Page 6 PROFINO REVOLUTION PLUS (REF. 6711) DISPLAY READOUT EXPLANATION To activate the correct channel frequency plan, select the country or region where the Profino Revolution Plus is situated. Rotate to select and confirm by tapping the rotary button. The default setting is Europe. The Profino Revolution Plus is also operational in the following countries/regions: Australia, Brazil, China, Hongkong, Italia, New-Zealand, Russia, South Africa, UK and USA.
  • Page 7 PROFINO REVOLUTION PLUS (REF. 6711) DISPLAY READOUT EXPLANATION Tap Add Channel to add channel. Up to 6 channels can be added at once. First select the starting channel (e.g. CH5) and tap to confirm. Then select the stop channel (e.g. CH7, this means that you will add 3 channels).
  • Page 8 PROFINO REVOLUTION PLUS (REF. 6711) To delete a (group of) channel(s), position the arrow on the channel and press the rotary button 3 seconds. DISPLAY READOUT EXPLANATION To delete a (group of) channel(s), position the arrow on the channel and press the rotary button 3 seconds. When you have added all the channels to INPUT VHF, and you want to add channels to the other inputs, scroll up to the top of the menu (to INPUT VHF), tap...
  • Page 9 PROFINO REVOLUTION PLUS (REF. 6711) ADVANCED SETTINGS DISPLAY READOUT EXPLANATION language of the Profiler Revolution can be set to English, Italian, Spanish or French. Tap REGION to check to which region/country the Profiler Revolution is set. To change the region/country, a hard reset is required (see instructions above (cfr.
  • Page 10 PROFINO REVOLUTION PLUS (REF. 6711) EXIT SETTINGS DISPLAY READOUT EXPLANATION To avoid unauthorized people changing the settings, all Profiler products can be locked with a security code. Select LOCK and SET LOCK CODE. When the lock code is set, the device will shut down. When you restart the device, you will now have to enter the correct lock code.
  • Page 11: Technical Specifications

    PROFINO REVOLUTION PLUS (REF. 6711) 2. T ECHNICAL PECIFICATIONS Profino Revolution Plus 6711 Inputs 1 FM + 1 DAB/VHF + 2 UHF Outputs 1 main (FM-VHF-UHF) + 1 test port (-30dB) Frequency range FM: 88 - 108 VHF:174 - 240 UHF: 470 - 862 LTE protection Automatic selection: 694, 790 or OFF...
  • Page 12: Block Diagram

    PROFINO REVOLUTION PLUS (REF. 6711) 3. B LOCK DIAGRAM...
  • Page 13: Safety Instructions

    PROFINO REVOLUTION PLUS (REF. 6711) 4. S AFETY NSTRUCTIONS Read these instructions carefully before connecting the unit To prevent fire, short circuit or shock hazard: • Do not expose the unit to rain or moisture. • Install the unit in a dry location without infiltration or condensation of water. •...
  • Page 14: Conditions Of Warranty

    If during this period of warranty the product proves defective, under normal use, due to defective materials or workmanship, Unitron N.V, at its sole option, will repair or replace the product. Return the product to your local dealer for reparation.

This manual is also suitable for:

Johansson 6711

Table of Contents