Gima LD-101 Manual
Gima LD-101 Manual

Gima LD-101 Manual

Manual breast pump
Hide thumbs Also See for LD-101:

Advertisement

Quick Links

PROFESSIONAL MEDICAL PRODUCTS
TIRALATTE MANUALE
MANUAL BREAST PUMP
TIRE-LAIT MANUEL
MANUAL DEL SACALECHES
BOMBA TIRA-LEITE MANUAL
MANUELLE MUTTERMILCHPUMPE
41700/LD - 101
JOYTECH HEALTHCARE CO.LTD.
No.365, Wuzhou Road,
Yuhang Economic Development Zone,
Hangzhou city, 311100 Zhejiang, China
Made in China
Shanghai International Holding Corp. GmbH (Europe)
Eiffestrasse 80, 20537, Hamburg, Germany
Importato da / Imported by / Importé par /
Importado por / Importado por / Importiert von:
Gima S.p.A. Via Marconi, 1 - 20060 Gessate (MI) Italy
gima@gimaitaly.com - export@gimaitaly.com
www.gimaitaly.com
55°C
93%
-20°C
15%

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LD-101 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Gima LD-101

  • Page 1 Shanghai International Holding Corp. GmbH (Europe) 55°C Eiffestrasse 80, 20537, Hamburg, Germany Importato da / Imported by / Importé par / -20°C Importado por / Importado por / Importiert von: Gima S.p.A. Via Marconi, 1 - 20060 Gessate (MI) Italy gima@gimaitaly.com - export@gimaitaly.com www.gimaitaly.com...
  • Page 2: Table Of Contents

    ENGLISH Index Product Description ....................14 Safety Notice ......................14 Unit Illustration ......................15 Installation Instructions .................... 16 Product Assembly ....................16 Pumping ........................19 Size of Breastshield ....................20 Cleaning ........................21 Trouble Shooting ....................... 22 Waste Treatment ....................... 22 Maintenance ......................
  • Page 3: Product Description

    ENGLISH Product Description Thank you for purchase and use LD-101 manual breast bump. The manual breast pump is used to express and collect breast milk from lactating mothers. Please read this manual carefully before using stimulation and expression mode. This is a single use product that should not be shared between moms.
  • Page 4: Unit Illustration

    ENGLISH Unit Illustration 1. 1 × Elastic diaphragm 7. 1 × Breastshield 13. 1 × Dome cap 2. 1 × Stem 8. 1 × Pump body 14. 1 × Nipple 3. 1 × Handle 9. 2 × Valves 15. 1 × Screw ring 4.
  • Page 5: Installation Instructions

    ENGLISH Installation Instructions Product Assembly Note: Make sure you have cleaned and optionally disinfected the appropriate parts of the breast pump. After cleaning, follow these steps to assemble your collection units: Step 1: Insert the breastshield into the funnel-shaped section of the pump body. Two breastshield sizes are available:24mm and 27mm.
  • Page 6 ENGLISH Step 2: Please install the white membrane on valve smoothly. Make sure the white membrane won’t curl up. Step 3: Insert the valve into the pump body from un- derneath. Push the valve in as far as possible. Step 4: Screw the pump body clockwise onto the bot- tle until it is securely fixed.
  • Page 7 ENGLISH Step 5: Insert the stem into the hole of the elastic diaghragm. Push the stem in as far as possible. Place the diaphragm with stem into the seal seat, make sure the diagh- ragm edge and seal seat edge close fitting. If there’s no “O” shaped sealing ring on the plug at the bottom of the sealing seat, please put in on.
  • Page 8: Pumping

    ENGLISH Step 7: Insert the seal seat in the hole of the connec- tor and screw the seal seal clockwise until it is securely fixed. Pumping Relax in a comfortable chair (you may wish to use cushions to support your back). Press the assembled pump body against your breast.
  • Page 9: Size Of Breastshield

    ENGLISH Do not continue pumping for more than 5 minutes at a time if you do not succeed in expressing any milk. Use bottle holder to prevent the bottle from tipping over. Do not fill the bottle too full to o prevent overfilling and spillage.
  • Page 10: Cleaning

    ENGLISH Cleaning Caution 1. Clean and sanitize the parts below before using your pump for the first time. 2. Only use drinking-quality tap or bottled water for cleaning. 3. Take apart and wash all parts that come in contact with the breast and breastmilk immediately before and after use to avoid dry up of milk residues and to prevent growth of bacteria.
  • Page 11: Trouble Shooting

    ENGLISH Trouble Shooting Abnormal phenomenon Cause analysis Solutions Inspect all connection points to Connection points is loose ensure attachment is secure Low or No Suction The valve is chipped or Replace valve and/or membrane cracked or there’s holes or prior to pumping tears on membrane is Replace a appropriate size Breastshield size is not fit...
  • Page 12: Specifications

    (warnings) ative in the European complies with carefully community Directive 93/42/EEC Keep away from Manufacturer Serial number sunlight Consult instructions Product code Lot number for use Temperature limit Humidity limit GIMA WARRANTY TERMS The Gima 12-month standard B2B warranty applies.