  • Page 1 様式-2 FTS-B580-03 S218R-200 Thermal Stripper Operating Instructions • Please read entire manual prior to usage. • Please keep this manual with the S218R-200. Issue 03 November. 2019...
  • Page 2: Table Of Contents

    Contents Contents ......................1 Safety Instructions ..................2 Components ....................5 2.1 Standard Components ................5 2.2 Optional Components ................5 Specifications .................... 5 Unit Description ..................6 Preparation ....................7 5.1 Battery setting ..................7 5.2 Charging the Battery ................8 Operating Instruction .................
  • Page 3: Safety Instructions

    • If the S218R-200 is dropped and damaged, disconnect the power source. Continuing to operate under these conditions may cause fire or electrical shock. • Do not operate the S218R-200 at temperatures less than 0ºC or above 40ºC. Do not expose to high temperatures. Doing so may cause fire, electrical shock or malfunction.
  • Page 4 • Do not use in a humid, dirty or vibration site. Doing so may cause fire, electrical shock or malfunction. • Do not place the S218R-200 on an unstable or inclined surface. The S218R-200 may fall and cause injury. • Disconnect all cords when using DC cord and moving the S218R-200. Doing so may damage the cords which may cause fire or electrical shock.
  • Page 5 Notes This symbol mark is for EU countries only. This symbol mark is according to the directive 2006/66/EC Article 20 Information for end-users and Annex II. This symbol means that batteries and accumulators, at their end-of-life, should be disposed of separately from your household waste. If a chemical symbol is printed beneath the symbol shown above, this chemical symbol means that the battery or accumulator contains a heavy metal at a certain concentration.
  • Page 6: Components

    Tools used for removing the Battery Pack Case S218X-04 Protection Case Strap Cleaning brush Operating Manual FTS-B580 2.2 Optional Components Name Code Quantity Remarks Blade for S218R-200 S218X-55 1(set) Battery Pack S944 Li-Ion Battery AC→DC Converter AC adaptor S952 Stand S218X-23 3 Specifications Description...
  • Page 7: Unit Description

    4 Unit Description Mode switch Temperature Trimmer Screw for the Battery cover Charge status LED Battery cover DC jack Rear side Front side - Polarity of DC jack...
  • Page 8: Preparation

    5 Preparation 5.1 Battery setting Mount the S944 Battery Pack into the S218R-200 before using it. 1) Loosen the screw of the Battery cover by using an attached Phillips-head screwdriver. 2) 2) Remove the Battery cover by pushing it to the direction as shown at right.
  • Page 9: Charging The Battery

    2) Connect S952 AC adaptor to AC power outlet (85-264V, 50/60Hz) using AC power cord. 3) Connect S218R-200 Main body to S952 AC adaptor using DC plug cable. 4) The orange charge LED will be illuminated and the battery will start to be charged.
  • Page 10: Operating Instruction

    Connect to a power source with appropriate wiring (DC/DC converter only) and press power switch. The Indication Lamp (LED) lights red to indicate power is being supplied to the S218R-200. The LED color will change from red to green approximately 15 seconds later to indicate that the S218R-200 is warmed up and ready to use.
  • Page 11: Adjusting Temperature

    Attach S944 battery to the S218R-200 and charge it using S952 AC adapter. 10 Confirming Battery Remaining During using S218R-200 with S944 battery, continuing to press the power switch for more than 2 seconds will cause the S218R to show the battery power remaining with indication lamp. (Green/Red LED) Each state of LED shows the condition of the battery and remaining power as per following table.
  • Page 12: Replacing The Blade

    12 Replacing the blade 2 of Upper blade adjusting screw (0.9mm) Upper blade 2 of Upper blade set screw (2-M2×1.5mmL) Lower blade 2 of Lower blade set screw(2-M2×1.5mmL) 12.1 Replacing the lower blade 1) Remove two lower blade set screws, and take off the lower blade. 2) Set the new lower blade temporarily with the set screw tightened slightly.
  • Page 13: Upper Blade Adjustment

    If S944 Battery Pack needs to be stored for more than 1 month without being used, please store it using the following procedure. Remove the S944 Battery Pack from S218R-200 Main body, then move that to proper storage area. Maintain the storage environment under following conditions, temperature: -20°C to +20°C, and humidity: 15 to 95 %RH without condensing.
  • Page 14: Holding Period For Spare Parts

    14 Holding period for spare parts We will have and hold the spare parts for repair and replacement at least 6 years after these products are discontinued for production. During the period, we will repair this product. Beyond the period, we may be able to repair this product depending on the problems, please contact Furukawa electric Co., LTD or your local sales representative for further assistant.