Content:
01 SAFETY INFORMATION
01.1 Risk of eyes damage
01.2 Protection from electric shock
01.3 Fire prevention
02 PRODUCT SPECIFICATION
02.1 Technical Specification
02.2 Dimensions
02.3 Back panel
03 INSTALLATION
03.1 Unpacking
03.2 Physical installation
03.3 Connecting to AC power
03.4 Control data connecting
03.5 DMX channels
04 MAINTENANCE
ENVIRONMENT
Do not throw away the appliance with the normal household waste at the end of its life,
but hand it in at an official collection point for recycling. By doing this, you help to preserve
the environment.
©MMVIII - Leader Light – All right reserved
Leader Light s.r.o.
01
SAFETY INFORMATION
M.Gorkeho 33
SK-052 01 Spisska Nova Ves
Slovakia
www.leaderlight.eu
USER MANUAL
WARNING!!!
Carefully read before installing, powering or servicing.
Nothing to do if anything misunderstand!
Only for professional use!
01.1 Risk of eyes damage
- Do not look directly into LED lamps.
- Do not look into light beam from a distance of less than 40 cm (16 inches)!
120
01.2 Protection from electric shock
x
x
80
x
x
x
x
- Shut down power before installation or maintenance.
- Luminaries and recommended power supply must be installed by a qualified professional in
accordance with relevant local codes.
Only acceptable source of AC power and frequency that complies with local buidling and electrical
codes to use.
1 pc.
- Do not use or do not connect the products if the power cable, power plug or fixtures are any way
damaged, wet, or if they are overheating.
1 pc.
- Do not modify, alter, or attempt to service the LeaderLight appliance.
Doing so will void the warranty.
1 pc.
- Before removing or installing any cover or part of appliance disconnect it from AC power.
- Appliance allways connect to earth (eltech.).
2 pcs.
01.3 Fire prevention
1 pc.
1 pc.
- Follow all safety consideration.
- Thermostatic switches or fuses never to bypass.
1 pc.
- Device never shield. Around the axis of the fitting (180°) must be maintained space for cooling.
Minimum distance from the surrounding objects must be 100mm (4 in.) (figure 1.1).
- LEDs never direct cover with filters or other materials.
- Allowing max. ambient temperature is 40°C (104°F).
- Luminaries never use without mounting brackets. The housing never install directly to the surface.
02 PRODUCT SPECIFICATION
02.1 Technical Specification
Control data Input:
Input power:
Power Connection:
Dimensions LxWxH:
Ambient temp. (Ta):
Materials and finish:
Lamp type:
120 x RGBAW P4
(Red, Green, Blue, Amber and White - 6300K)**
Long 60 000 hrs 60% degradation
Lifetime:
Optic:
25mm standard 25°
optional 10°, 40° and 15°x90° - on request
DMX 512 in/out with XLR 5PIN
max. 200W
100-260V AC 50-60Hz in/out PowerCon
11kg
Net weight:
1000mm x 120mm x 80mm without bracket
IP:
IP20
Maximum 40°C
Cooling:
Conventional
Housing: powder-painted anodized aluminium RAL9006 (other
colours on request)
Cover: clear or frosted PMMA
Installation:
Any position for ceiling, wall and surface-mounting
Edition: A - 2008
02.2 Back panel
DMX OUT
DMX IN
Power IN
Control LEDs
XLR-5PIN
XLR-5PIN
PowerCon
» Rotating DIP address 000÷511
Dip options
"100" "10" "1"
Control LEDs Indication
LED
INDICATION
STATUS
POWER (Red)
blinking – 2Hz
OK - inside fixture is everything correct
DATA (Green)
light off
NO DMX512 signal
DATA (Green)
blinking – 4Hz
OK- income correct DMX512 signal
DATA (Green)
fast blinking
NON correct digital signal
POWER (Red)
alternate blinking
Autotest function
DATA (Green)
03 INSTALLATION
03.1 Unpacking
- Unpack carefully.
- This is electronic equipment and should be handled carefully.
- Damaged delivered package or if are any mechanical parts broken – it must be claim
immediately by the transport company.
Photo pictures as evidence are valuable for future claim.
03.2 Physical installation
- Loading capacity of bearing area has to be at least 10 times the weight of all device clusters
(luminaries, clamps, cables, ...).
- Heigrbreadth from combustible materials is 0,5m.
03.3 Connecting to AC power
- To tackle all Safety Information- 01!
- For protection from electric shock, the device must be grounded (earthed)!
- It is not necessary to open the fixture before power supply.
Power supply is sovled simple with Neutrik PowerCon connectors.
- The fixture is equipped with auto-switching power supply that automatically adjusts
to any 50-60 Hz AC power source from 100-260 Volts.
- Cord plug connections:
Symbol
Pin
Wire Colour
L
live
brown
N
neutral
blue
ground (earth)
yellow/green
03.4 Control data connecting
- Control data cable length is specified by Norm IEC929 Annex E4.
- It is not necessary to open the fixture before connecting of DMX512 control signal.
Interconnections are realized by Neutrik XLR 5 PIN IN/OUT connectors.
- Pin connections :
Pin 1 – ground
Pin 2 – signal negative
Pin 3 – signal positive
If you have any question please, contact support@leaderlight.sk
Power OUT
PowerCon
POWER
DATA
Screw (US)
yellow or brass
silver
green

Advertisement

loading

Summary of Contents for Leader Light LL LED FLOOD NEO Z-POWER RGBAW

  • Page 1 DATA (Green) codes to use. - LL LED FLOOD NEO Z-POWER RGBAW 5m power cable with PowerCon 1 pc. - Do not use or do not connect the products if the power cable, power plug or fixtures are any way damaged, wet, or if they are overheating.
  • Page 2 03.5 DMX channels *** DIP1=Off a DIP4=On switch on AutoRun – table functions Rotating Dip Rotating Dip Program Nr. 2: “100“ “10“ “1“ Step Time: DMX channels and DIP Switch: step 1 step 2 Mode 1 (5+2 channels): DIP2=Off and DIP3=Off step 3 channel 1 = 0-100%...

This manual is also suitable for:

Ll44 200