Dip Switch Settings - HME VDB103 Installation Instructions Manual

Vehicle detector board
Table of Contents

Advertisement

DIP SWITCH SETTINGS

Before installing the VDB103/VDB103R, the following six functions can be set by switching/moving the switches as indicated
below. Refer to Figure 3, below.
* = factory setting
Clears vehicle detection after 20 minutes.
Lower detection sensitivity corresponds
to slower detection at the risk of small
fluctuations causing missed detections.
Release Sensitivity correlates to how
quickly the VDB103/VDB103R will signal
vehicle departure (higher sensitivity
means departures trigger more easily).
Verifies connection between VDB103/
VDB103R and Base.
Controls the delay between detection and
the actual signaling of detection.
ON is the default setting. Do not change.
Figure 3. SW1 DIP switch on VDB103/VDB103R circuit board
(Default pin positions displayed)
Switch #1
OFF
ON
Switch #2
OFF
ON
Switch #3 Switch #4 Release Sensitivity
OFF
OFF
ON
ON
Switch #5 Diagnostic Mode
OFF
ON
Switch #6 Switch #7 Delay
OFF
OFF
ON
ON
Switch #8
OFF
ON
Vehicle Presence Auto Reset
No Timeout
20 minute timeout for vehicle presence *
Detection Sensitivity
Normal Sensitivity *
Low Sensitivity
OFF
Low
ON
Medium *
OFF
High
ON
Extra High
Normal VDB103/VDB103R Operation *
Detection is Suspended - DSP firmware
scrolls, and car presence is cycled every 10
seconds (On 10 seconds, Off 10 seconds)
OFF
6 seconds
ON
4 seconds
OFF
2 seconds
ON
0 seconds *
Daily Log
Weekly Log *
4