Aertesi SOFFIO Series Installation, Use And Maintenance Manual

Aertesi SOFFIO Series Installation, Use And Maintenance Manual

Ducted units

Advertisement

AERTESI srl
SOFFIO
INSTALLATION USE AND MANTEINANCE MANUAL
INSTALLATION,
USE AND MAINTENANCE MANUAL
SOFFIO – SOFFIO HP
Ducted units
Page 1
AER.MIU.GB.SOFFIO.000.02.15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SOFFIO Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Aertesi SOFFIO Series

  • Page 1 AERTESI srl SOFFIO INSTALLATION USE AND MANTEINANCE MANUAL INSTALLATION, USE AND MAINTENANCE MANUAL SOFFIO – SOFFIO HP Ducted units Page 1 AER.MIU.GB.SOFFIO.000.02.15...
  • Page 2: Table Of Contents

    AERTESI srl SOFFIO INSTALLATION USE AND MANTEINANCE MANUAL INDEX 1-INTRODUCTION............................3 2-RECEPTION…………………………………………………………………………………………………………..3 3-POSITIONING ..............................3 4-INSTALLATION .............................. 4 5-AERAULIC CONNECTIONS .......................... 6 6-IDRAULIC CONNECTIONS ........................... 7 7- ELECTRICAL CONNECTIONS ........................7 8-MANTENANCE .............................. 9 8.1-Filter ................................. 9 8.2- Fan (motor standard ) ........................... 10 8.3- Fan (HP motor high prevalence) ......................
  • Page 3: 1-Introduction

    AERTESI srl SOFFIO INSTALLATION USE AND MANTEINANCE MANUAL 1-INTRODUCTION Series units SOFFIO are designed for the function of heating, cooling, dehumidification and filtration of residential and commercial application (offices, public buildings, or so) with the counterceiling. Following applications are not permitted: 1.
  • Page 4: 4-Installation

    AERTESI srl SOFFIO INSTALLATION USE AND MANTEINANCE MANUAL Meet the following minimum spaces that are needed for installation and maintenance. It’s also need a minimum space on the suction side (filter side), at least equal to the height of the unit.
  • Page 5 AERTESI srl SOFFIO INSTALLATION USE AND MANTEINANCE MANUAL 31/38 1148 41/81 1698 21HP 38HP 1148 81HP 1698 91HP 1748 101HP 1998 21 vertical 31/38 vertical 1148 41/81 vertical 1698 Positioning of suspension bars Lift the machine using a suitable lifting device (hoist, forklift or other) appropriate, that can support the weight of the machine.
  • Page 6: 5-Aeraulic Connections

    AERTESI srl SOFFIO INSTALLATION USE AND MANTEINANCE MANUAL Check that the machine is perfectly horizontal or sloping slightly towards the condensate drain (never counter slope). If necessary adjust the height by means of the nut and locking nuts that hold the threaded rod to the bracket.
  • Page 7: 6-Idraulic Connections

    AERTESI srl SOFFIO INSTALLATION USE AND MANTEINANCE MANUAL 6-IDRAULIC CONNECTIONS The unit is equipped with coil suitable to work with water, water mixed with glycol. In wither season there is the possibility to empty the water circuit if there is a risk of icing inside the battery.
  • Page 8 AERTESI srl SOFFIO INSTALLATION USE AND MANTEINANCE MANUAL Power cables must be dimensioned with reference to the maximum current absorption of the unit, indicated in the label and in the technical manual, but not less than 0,75mmq. The control thermostat must be able to support the current absorbed from the unit and the start current of the fan.
  • Page 9: 8-Mantenance

    AERTESI srl SOFFIO INSTALLATION USE AND MANTEINANCE MANUAL Cables access Fairlead Before the electrical installation, see the specific circuit diagram of the unit supplied with the machine. After completing the electrical installation, replace the electrical panel cover and secure it with screws.
  • Page 10: Fan (Motor Standard)

    AERTESI srl SOFFIO INSTALLATION USE AND MANTEINANCE MANUAL Removal from the bottom / side of the filter machines with engines average prevalence For high prevalence sizes (HP) is only possible the extraction of the filter from below. For vertical sizes is only possible extraction from the front.
  • Page 11 AERTESI srl SOFFIO INSTALLATION USE AND MANTEINANCE MANUAL Remove the bottom panel Then unscrew the M6 screws that secure the motor plate to the machine frame (2 screws for size 21, 4 screws for size 31/38, 5 screws for size 41/81).
  • Page 12: Fan (Hp Motor High Prevalence)

    AERTESI srl SOFFIO INSTALLATION USE AND MANTEINANCE MANUAL Removing the motor plate After replacing the fan, install all the components performing the same operations in reverse order. 8.3- Fan (HP motor high pressure) In versions “High Prevalence” , after removing the bottom panel and disconnect the motor cables as described in the previous paragraph, you must remove individual fans, not the whole plate.
  • Page 13: 9- Troubleshooting

    AERTESI srl SOFFIO INSTALLATION USE AND MANTEINANCE MANUAL After replacing the fan, install all the components performing the same operations in reverse order. 9- TROUBLESHOOTING Anomaly Possible failures Remedy The fan does not There is no current Check the breaker / fuse...
  • Page 14 NOTES: ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ Aertesi srl. reserves the right to introduce at any time whatever modifications deemed necessary for improving the product with possible modification of the relevant technical data Page 14 AER.MIU.GB.SOFFIO.000.02.15...
  • Page 15 Aertesi srl Unipersonale viale della tecnica, 6a 35026 Conselve (PD) ITALY t. +39.049.9501109 f. +39.049.9500823 www.aertesi.com info@aertesi.com...

Table of Contents