  • Page 1 Small Duct High Velocity Heating, Cooling and Home Comfort Systems HE-B Series Commissioning Report & User Guide Manufactured By www.hi-velocity.com Module-HEB-COM-Commissioning-Report-and-User-Guide-111020 Module-HEB-COM-Commissioning-Report-and-User-Guide-111020...
  • Page 2 On: (Active) On: (Active) = Light On Light On On: (Inactive) On: (Inactive) ON: (INACTIVE) = = Light Off Light Off Off: Off: OFF: 2 SECONDS Module HEB-COM-Commissioning-Report-and-User-Guide (2/8) © 1995-2013 Energy Saving Products Ltd. © 1995-2013 Energy Saving Products Ltd.
  • Page 3 HE-B-100/101 4 Tons 1488 1323 1190 1082 (1420) (1291) (1184) (1093) 5 Tons 1488 1353 1240 1145 Outlet Velocity (FPM) (FPM ÷ 100 = Knots) Module HEB-COM-Commissioning-Report-and-User-Guide (3/8) © 1995-2013 Energy Saving Products Ltd. © 1995-2013 Energy Saving Products Ltd.
  • Page 4 ________ FPM per 2” Outlet Heating ________ FPM per HE Outlet ________ FPM per 2” Outlet* Constant Fan ________ FPM per HE Outlet ________ FPM per 2” Outlet Module HEB-COM-Commissioning-Report-and-User-Guide (4/8) © 1995-2013 Energy Saving Products Ltd. © 1995-2013 Energy Saving Products Ltd.
  • Page 5 Knots to CFM of 2” outlets = x 2.2 Knots to CFM of HE outlets = x 4.2 Columns Total Velocity = Columns Total CFM = Grand Total CFM = Module HEB-COM-Commissioning-Report-and-User-Guide (5/8) © 1995-2013 Energy Saving Products Ltd. © 1995-2013 Energy Saving Products Ltd.
  • Page 6 Knots to CFM of 2” outlets = x 2.2 (Cooling, Heating, Constant) and adjust the system accordingly. Knots to CFM of HE outlets = x 4.2 Module HEB-COM-Commissioning-Report-and-User-Guide (6/8) © 1995-2013 Energy Saving Products Ltd. © 1995-2013 Energy Saving Products Ltd.
  • Page 7 Use the damper key supplied from When it comes to servicing the Hi-Velocity HE-B System itself, Energy Saving Products for easy vent adjustments. only the 1” air filter requires maintenance on a regular basis. With a clean air filter, you not only have cleaner air to breathe, but you will also help maintain unit efficiency, and increase operating life.
  • Page 8 FAN OPERATION MODE ON: (ACTIVE) = Light On Light On ON: (INACTIVE) NO LIGHT = = Light Off Light Off OFF: 2 SECONDS 2 SECONDS 2 SECONDS Module HEB-COM-Commissioning-Report-and-User-Guide (8/8) © 1995-2013 Energy Saving Products Ltd. © 1995-2013 Energy Saving Products Ltd.