SIFCO ASC TechnoPlate Power Pack 6015A20V Operating Manual

With detachable control unit
Table of Contents

Advertisement

plating electronic GmbH
Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de
Documentation type:
Operating manual
Author:
J. Schumann
Last modification by:
Johannes Schumann
Last saving date:
2019-06-28
SIFCO ASC TechnoPlate Power Pack
Read this operating manual completely before installation.
Not following installation and operation procedures will void the warranty. It also
SIFCOTechnoPlate Power Pack_2019-05-06_V1.5_e.doc
Strictly confidential! No unauthorized circulation of content.
© All rights reserved by plating electronic GmbH. Modification and reproduction only by authorized persons!
-
Rheinstraße 4
Last modification:
Print date: 2019-06-28
Operating Manual for
with detachable control unit
could result in serious injury or death.
-
D-79350 Sexau
-
..\History_SIFCO TechnoPlate_001.xlsx
Germany
V1.5
Comment:
1/68

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ASC TechnoPlate Power Pack 6015A20V and is the answer not in the manual?

Questions and answers

Gilberto
April 14, 2025

what are the registers for the RS485 communication? I want to control the Voltage value form an external input and if possible, also the time, if not, I can do the programming from external source. Thank you.

Summary of Contents for SIFCO ASC TechnoPlate Power Pack 6015A20V

  • Page 1 Comment: Last saving date: 2019-06-28 Operating Manual for SIFCO ASC TechnoPlate Power Pack with detachable control unit Read this operating manual completely before installation. Not following installation and operation procedures will void the warranty. It also could result in serious injury or death.
  • Page 2 plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de SIFCOTechnoPlate Power Pack_2019-05-06_V1.5_e.doc 2/68...
  • Page 3: Table Of Contents

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de List of Contents: EU declaration of conformity ----------------------------------------------------------------- 5 General security information ----------------------------------------------------------------- 6 Class-A device ---------------------------------------------------------------------- 6 Security ------------------------------------------------------------------------------- 6 Installation of the DC power supply modules -------------------------------- 8 Operation conditions --------------------------------------------------------------- 8...
  • Page 4 Rectifier unit “SIFCO ASC TechnoPlate” (type: see package labeling, and rating plate) Control unit SIFCO ASC (for type 15A / 20 V and 30 A / 20 V: integrated control panel) Three types of mains power cord (individual plugs) for...
  • Page 5: Eu Declaration Of Conformity

    Karl Rieder (Managing Director) Product, to which the above declaration refers: Installation: electroplating DC power supply type SIFCO TechnoPlate POWER PACK air cooled, with integrated pole changer with preset counter, with RS485-BUS interface Serial No.: see rating plate SIFCOTechnoPlate Power Pack_2019-05-06_V1.5_e.doc...
  • Page 6: General Security Information

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de General security information Class-A device This device is defined as a class-A-device. Warning: This device is provided to be used only in industrial environment! In other environments, a sufficient electromagnetic tolerance could not be assured without additional installation measures.
  • Page 7 plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de This DC power supply was delivered after a thorough function- and safety-check. Only qualified staff shall connect the device and put it into operation.
  • Page 8: Installation Of The Dc Power Supply Modules

    D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Security advice: SIFCO TechnoPlate POWER PACK The DC-power-supplies of the series are designed as desktop units. The DC power supplies are only to be operated in the permissible ranges of current, voltage, environmental temperature and atmospheric humidity according to the rating plate and the operating manual.
  • Page 9: After Transportation

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de After transportation Check the device and the packaging and transportation material for damages caused by transportation! Never put a device into operation if there are visible or hidden transportation damages! Attention: After transportation, all electrical connections accessible by the customer...
  • Page 10: General Description

    Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de General description SIFCO ASC TechnoPlate Power Pack The DC-power supply type a sophisticated switch mode type rectifier, designed for the selective electroplating industry. It is designed as a desktop unit.
  • Page 11: Switch Mode Technology

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Switch mode technology This device was designed as switch mode type DC power supply. The advantages of the switch mode technology are: very compact design maximum regulation accuracy very low ripple...
  • Page 12: Detachable Control Unit

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Detachable control unit Assembling after transportation Plug the control cable to the socket at the control unit Latch the control unit to the rectifier unit For transportation, make sure the control unit is properly latched, and the protective cover is closed.
  • Page 13: Transport Lock For The Control Unit

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Transport lock for the control unit Use the delivered screw to fix the control unit during transportation: You can swing the control unit to adjust the angle of view. SIFCOTechnoPlate Power Pack_2019-05-06_V1.5_e.doc 13/68...
  • Page 14: Protective Cover

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Protective cover The protective cover plate is used to protect the control unit during transportation. It should be closed if the device is not in use. If the cover is opened, it could be used as a stand for manuals or process instructions.
  • Page 15: Control Unit With Stand

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Control unit with stand could also be hung up (use holes in plate) If unlatched, you can swing out the mounting plate of the control unit to use it as a stand for desk top positioning (extension control cable required, please order separately).
  • Page 16: Devices 15 A / 20 V And 30 A / 20 V

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Devices 15 A / 20 V and 30 A / 20 V The 15 A / 20 V type and the 30 A / 20 V type are the compact versions of the TechnoPlate Power Pack.
  • Page 17: Dc-Output Connection

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de DC-output connection Connect the DC-output connectors to the load. Check for right polarity and contact. Look for the DIN VDE 0298-4 / 2013-06 admitted cable cross section and the correct polarity.
  • Page 18: The Rs485 Bus Connection

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de The RS485 BUS connection There is a round four-pin socket located on the back plane of the device. BUS input This is used for remote RS485 BUS control of the device.
  • Page 19: Bus - Terminator

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Bus - terminator 4-pin female plug The BUS terminator is to be installed at the BUS output socket of the last participant within the RS485 BUS line.
  • Page 20: Mains Supply

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Mains supply Supply voltage: see device type and specification list. Use the delivered plug to connect the device to the corresponding mains supply.
  • Page 21: Power Cord Plug Single-Phase Type

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de 10.1.1 Power cord plug single-phase type 10.1.2 PFC technology For single-phase devices only: The PFC technology (Power Factor Control) allows a reduced phase current by increasing the efficiency of the power part.
  • Page 22: Phase Devices

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de 10.2 3~phase devices Connection scheme: Outside view on the socket 10.2.1 Power cord plug three-phase type SIFCOTechnoPlate Power Pack_2019-05-06_V1.5_e.doc 22/68...
  • Page 23 plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Mains cable specification Only connect supply cables that are in conformance with the following standards: DIN VDE 0298-4 / 2013-06 Use equivalent regulations that are valid for the country the device is used in.
  • Page 24: Back Plane

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Back plane 1 = Power socket 2 = RS485 BUS input connector 3 = RS485 BUS output connector 4 = Cooling air outlet If the BUS connectors are not used, apply protective covers to the sockets!
  • Page 25: Operation

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Operation 12.1 Main switch The DC-power-supply must be switched on by using the main switch in the front panel. The control unit gets started if the switch is set to ON.
  • Page 26: Function Overview Of The Software

    D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Function overview of the software The following control functions are implemented for the present SIFCO software: Preset settings “PRESET” Overload detection Manual pole changer “+/-“...
  • Page 27: Ampere-Hour Counter And Reset Function

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Ampere-Hour Counter and Reset function This is the PRESET counter for alarm output and AUTO-switch-off. 15.1 A/H value setting (A/H PRESET) Press the A/H PRESET key to set the preset value (see detailed description in item 20.5 Preset counter).
  • Page 28: Potentiometer Control And Step Function

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Potentiometer control and step function The digital potentiometers have several functions: potentiometer control (value adjusting for DC output by turning the knobs) reset value to zero (push knobs longer than 3 seconds) digit selection (move digit marking from right to left by pushing the...
  • Page 29: Potentiometers Control For Voltage And Current

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Potentiometers control for voltage and current Current and voltage settings are done by two digital endless potentiometers with integrated push-button function. A 360°-turn of each potentiometer has a resolution of 32 step-positions.
  • Page 30: Control Function

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de 17.1 Control function Description about the functionality of the digital potentiometers and how these can be used as follows: push to select digit one digit to the left turn to adjust value...
  • Page 31: Function 1 "Counting

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Function 1 “Counting” 17.1.1 By turning the potentiometer, the digit starts counting, in the below example in 0.01 V steps, until the maximum 99.99 V is reached. The start point of the counting is always the digit that was used the last, or, after a restart of the control unit, the rightmost digit.
  • Page 32: Function 2 "Jumping

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Function 2 “Jumping” 17.1.2 By pushing the potentiometer, you will enter the digit selection mode. With each push, you move the digit selection from right to left. The starting point is the digit position that was selected the last, or, after a restart of the control unit, the rightmost digit.
  • Page 33: Function 3 "Counting And Jumping

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Function 3 “Counting and Jumping” 17.1.3 By turning the potentiometer, the digit starts counting; in the below example in 0.01 V steps, from 0 until 0.09 V. By pushing the potentiometer one time, the digit selection is moved to the left.
  • Page 34: Function 4 "Digit Reset

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Function 4 “Digit reset” 17.1.4 By pushing and holding the potentiometer for 2 seconds, all digits located to the right side of the selected digit will be set to zero. The below example shows a value of 5.47 V.
  • Page 35: Step Function

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Step function The step function is used for a fast recall of stored preset values. A step preset includes the following parameters: DC voltage DC current Preset ampere-hour counter set value...
  • Page 36: Step And Next Step Keys

    “1” or higher will be selected. If step “Normal Operation”” is selected, the actual values are shown permanently on the display. The factory preset parameters will be predefined by SIFCO. The factory settings include 10 preset steps. More steps can be predefined in the step menu.
  • Page 37: Store Key

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de 18.2 STORE key The STORE key has two functions: By pushing the STORE key, the display shows for 2 sec.
  • Page 38: Label Key

    Example: If step 1 of 10 is loaded, the label is indicated with “01/10:” Behind the step number indication, the individual labeling can be done with max. 14 characters as follows: 0 – 9; A – Z; „.“ and „-“ and ˽ (free space). Example 01/10: 87586-SIFCO SIFCOTechnoPlate Power Pack_2019-05-06_V1.5_e.doc 38/68...
  • Page 39 plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Procedure: Press “LABEL” key The display shows: Use the STORE key to select characters in ascending direction: ˽ . - 0 1 2 3 4 5 6 7 8 9 A B C D …...
  • Page 40: Creating A Preset At Step 1

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de 18.5 Creating a preset at STEP 1 Starting point: Normal operation  STEP function is deactivated Start with key “NEXT STEP” =>...
  • Page 41 plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de If the voltage and current setting is finished: Press Ah PRESET key: Within 15 seconds, press STORE key to increase and STEP RESET key to decrease the Ah preset value on the left side of the...
  • Page 42: Examples How To Adjust Set Values

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Examples how to adjust set values These examples show how you can adjust a set value. However, there are alternative possibilities to adjust set values as well.
  • Page 43: Example 2: Adjust Voltage Set Value To 24.53 V

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de 19.2 Example 2: Adjust voltage set value to 24.53 V Turn voltage knob to adjust value in steps of 10 mV, up to 0.03 V 00.00 00.03 push 1 x...
  • Page 44: Adjust Existing Preset Values And Store New Values

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de 19.3 Adjust existing preset values and store new values If the STEP function is activated (STEP 1 or higher loaded), you can correct the values in OFF mode as well as in ON mode.
  • Page 45: Settings In Main Menu

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Settings in main menu 20.1 General description Open the main menu by pressing the ENTER key. The display shows: Select the desired menu point by pressing the corresponding key.
  • Page 46: The Settings Functions

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de 20.2 The SETTINGS functions If you are in the main menu as shown above, press the corresponding key for “Settings”. Eventually, change display page to come to the desired item.
  • Page 47: Configuration Of Bus Interface

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de 20.3 Configuration of BUS interface If you are in the in the “Settings” menu, press the key located beside the RS485 BUS line. The display shows: The following menu points are available in this menu: - Mode:...
  • Page 48 plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Menu point “Baudrate” The data transfer rate can be set to several fix values: 1200 2400 4800 9600 14400 19200 28800...
  • Page 49: Total Counter

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de 20.4 Total counter The totalizer (Total Counter) is not shown on the display. Therefore, you don’t need to do any settings here. This total counter is not relevant for the process.
  • Page 50: Preset Counter

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de 20.5 Preset counter If you are in the in the “Settings” menu, press the key located beside the Preset counter line. The display shows: In the preset counter menu, five items are available: - Direction:...
  • Page 51: Configuration Of The Preset Counter

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de 20.5.1 Configuration of the preset counter Menu point “direction” Set the counting direction of the preset counter: - up: counter counts from zero to preset value (incremental) - down: counter counts from preset value downwards to zero (decremental)
  • Page 52 plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Menu point “Reset now” In this menu point, you can reset the actual count of the preset counter. Select “NO”...
  • Page 53 plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Menu point “Switchoff” The switching functions for the DC power supply after the preset counter has reached the final value can be configured here. The Following settings are available: inactive = switching off disabled...
  • Page 54: Pole Changer

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de 20.6 Pole changer If you are in the in the “Settings” menu, press the key located beside the Pole changer line: The display shows: Note: The DEFAULT setting (manufacturer setting) is “Manual”...
  • Page 55 plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Mode Possible settings: manually or auto manually: The +/- key is used to set the output polarity. The manual mode is set by manufacturer when shipped. The pole changer function generates an acoustic beep sound when the pole changer will be switched to “reverse”...
  • Page 56: Overload Detection

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de 20.7 Overload detection Usually, the operating mode for the expected use of this DC power supply is CV (Constant Voltage regulation). The process this device is used for should never be affected by a short- circuit.
  • Page 57: Configuration Of The Overload Detection

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de 20.7.1 Configuration of the Overload detection If you are in the in the “Settings” menu, press the key located beside the Overload detection line.
  • Page 58: The Step Menu

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de 20.8 The STEP menu Press the “ENTER” key, select “Settings” and then select “STEP function”. The display shows: This is for information only;...
  • Page 59: Technical Data

    Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Technical data 21.1 General specifications SIFCO TechnoPlate POWER PACK Device type: Plating DC power supply Models: 6015A20V 300 W Function: 6030A20V...
  • Page 60: Individual Specifications

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de 21.2 Individual specifications 21.2.1 Type 6015A20V DC-output voltage: 0 - 20 V, continuously variable DC-output current: 0 - 15 A, continuously variable DC-output power: max.
  • Page 61: Type 6060A20V

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de 21.2.4 Type 6060A20V DC-output voltage: 0 - 20 V, continuously variable DC-output current: 0 - 60 A, continuously variable DC-output power: max.
  • Page 62: Dimensions

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Dimensions Size 1: Dimensions, protective cover closed SIFCOTechnoPlate Power Pack_2019-05-06_V1.5_e.doc 62/68...
  • Page 63 plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Protective cover The control unit is located behind the protective cover. Using an extension control cable, the control unit could be unlocked from rectifier unit and placed nearby.
  • Page 64 plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Size 2: SIFCOTechnoPlate Power Pack_2019-05-06_V1.5_e.doc 64/68...
  • Page 65: Checking Calibration

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Checking calibration To check calibration of DC output current and voltage, some special tools are required: digital measuring instrument for voltage measurements with high-end measuring lines The measuring instrument needs to be calibrated.
  • Page 66: Current Calibration

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de 23.2 Current calibration This is the measurement setup for current calibration: Make sure the DC cables have sufficient cross section for the maximum expected DC current!
  • Page 67: Service And Maintenance

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Service and maintenance This device is extensively maintenance-free. It is recommended to perform the following maintenance tasks at regular intervals: Clean the fans and the air ducts Check up the fans on functionality and unusual noises...
  • Page 68: Spare Parts List

    plating electronic GmbH Rheinstraße 4 D-79350 Sexau Germany Tel.: +49 (0)7641 / 93500-0 - Fax.: +49 (0) 7641 / 93500-999 E-Mail: info@plating.de Spare parts list On request Warranty and Repair Information This unit has a two-year manufacturer’s warranty, subject to the terms and conditions of the manufacturer.

Table of Contents

Save PDF