OUTPUT SIGNAL CONNECTIONS
The unit also provides output signal capabilities (SPDT Relay Output Contact) for connection to a home
security panel or for use with an appropriate relay to control a secondary device, such as a pump. See
Figure 2 for wiring diagram.
Normally Closed Circuit – Terminal Pins 3 & 4
OPERATION & SYSTEM RESET
In the event the system activates, locate the source of the leak, remove the sensor from the water and
dry the metal contacts on the bottom. Correct the problem causing the leak and replace the sensor in
the desired leak detection location once again as required. Press and release the "Reset" button on the
receiver to open the valve and begin the flow of water again. The green "Power" indicator light on the
receiver will flash once to confirm the reset. Confirm reactivation of the power-vent unit.
MAINTENANCE
Test the system annually per the function test (install step 10) to ensure correct operation and maintain
product warranty status. At a minimum, exercise (press and release) the "Reset" button on the receiver.
EMERGENCY MANUAL VALVE OPERATION
The unit is equipped with an emergency feature for the manual rotation of the valve. Disengage the
actuator from the valve and manually changing the valve to open or closed as follows:
1. Turn off the main power to the transformer.
2. Stabilize the water feed line by grabbing it in one hand near the valve. While grasping the actuator
housing in the other hand, pull the actuator housing away from the water feed line.
3. Using an appropriate hand tool (such as a pliers), clamp down on valve stem and turn in the appropriate
direction until the desired position is achieved. Note the top of the stem is slotted to indicate valve
position (in line with water flow indicates open valve; slot across water line indicates closed).
4. Before remounting the actuator, return the valve to the original position prior to the manual rotation.
5. Remount the actuator and restore the main power to the transformer.
6. Test for correct operation per the function test listed in install step 10.
DANGER – Electrocution Hazard
For use in dry locations only. Always unplug the relay module before servicing or installation. For continued
protection against electric shock, plug into grounded outlets only and do not remove the ground pin.
DANGER – Risque d'électrocution
À utiliser dans des endroits secs uniquement. Toujours débrancher le module de relais avant l'entretien ou
l'installation. Pour une protection continue contre l'électrocution, uniquement brancher à des prises mises à la terre
et ne pas retirer la broche de terre.
NEED INSTALLATION OR SETUP ASSISTANCE?
Call toll-free: 888-771-4929 or visit www.RelianceDetection.com/support/RS-094
© Copyright 2020 Reliance Detection Technologies, LLC – A Madison Company
203-488-2684 or 888-771-4929
27 Business Park Drive, Branford, CT 06405
www.RelianceDetection.com
All specifications subject to change without notice.
ECN # 11386, 09/2020, MF105, RevB
Normally Open Circuit – Terminal Pins 4 & 5
info@RelianceDetection.com

Advertisement

loading