  • Page 1 DMX Dimmer Pack 6ch User's Manual 10A x 6 channels dimmer pack with digital DMX / analog 0­10V input control and pre­heat function CO670L...
  • Page 2 CO670L WARNINGS This  unit  should  only  be  used  for  purpose  for  Make sure that cables cannot cause trip hazard. which  it  has  been  intended  and  should  be  Do not attempt to dismantle and modify the unit. installed  using  the  instructions  which  are  Due  to  the  high  technological  level  of  this  unit,  any service maintenance should be performed by  provided.  Arena  Luci  cannot  be  held  liable  for ...
  • Page 3: Before Starting

    Arena  Luci  dealer  Each  output  channel  has  a  10A  magnetic  circuit  immediately. breaker. The unit is equipped with a thermal­controlled fan.  n° 1 dimmer pack CO670L When  the  temperature  is  over  45°C,  the  fan  will  start automatically. Before  starting  the  installation  of  your  product  The auto tracking of frequency and phase enables  make  sure  that  there  are  no  evident  damages ...
  • Page 4: Installing The Unit

    CO670L REAR PANEL / TERMINAL BOARD (9) DMX IN/OUT (XLR­3 pin) (10) DMX IN/OUT (RJ11, phone jack) (11) Output terminal board (12) Power input terminal board (20A each phase) 9 10 INSTALLING THE UNIT Respect  the  L­N­E  polarity  indicated  on  the  terminals (color brown = L1 or L, black = L2, grey  The unit must be fixed on a suitable support which  remains  stable  during  operation.  Always  make  = L3, blue = N, yellow / green = E). It  is  essential  that  each  unit  is  correctly  earthed  sure the rack or structure to which you are setting  the unit is secure and is able to bear the weight of  and  that  electrical  installation  conforms  to  all  the ...
  • Page 5: Connecting Control Signals

    USER'S MANUAL CONNECTING CONTROL SIGNALS The  dimmer  pack,  in  order  to  be  remotely  controlled,  requires  a  digital  signal  DMX  512  (1990).  The  connection  between  controller  and  dimmer  pack  and  between  dimmer  pack  and  dimmer  pack  must  be  made  with  two­core  shielded  cable  with  a  section  of  at  least  0.5mm  ...
  • Page 6: Operation

    CO670L Pin  4  and  pin  5  are  not  connected.  For  RJ11  PROJECTOR ADDRESSES plugs: pin 1 = +12V, pin 2 = DATA+, pin 3 = DATA­ , pin 4 = GND.  Connect  the  signal  coming  from  the  controller  to  the  DMX  socket  of  the  unit  labeled  DMX  IN.  Continue  connecting  the  DMX  OUT  socket  to  the  DMX IN socket of the next unit.
  • Page 7 USER'S MANUAL present,  the  corresponding  output  channel  will  Dimming/Switch Setting Press DMX button into DMX status. take  the  higher  value  between  DMX  signal  and  slider value. Press and hold the FNC button for 3 seconds. The  default  setting  for  all  channels  (AL)  is  When the dimmer pack is receiving a DMX frame,  if  the  signal  is  lost  (or  the  cable  is  disconnected)  dimming mode (=d). the outputs will take the value set by the sliders. Also, ...
  • Page 8: Technical Specification

    CO670L TECHNICAL SPECIFICATION Power supply 90÷240 V AC ­ 45­63 Hz Output current 10A max each channel Control Standard DMX512/1990 control signal, 6 control channels     ­ Connector XLR 5pin IN/OUT (front) ­ Connector XLR 3pin IN/OUT (rear)     ­ Connector RJ11­6p4c phone jack IN/OUT (front + rear) Control Analog signal DC 0­10V, 6 control channels     ­ Connector D­type plug 9pin Female Channels 6 independent, phase­cut dimming, 230V ac outputs Connection Terminal blocks, input and output Material Aluminium and steel plate Colour Epoxy powder paint finish, black Insulation class Weight 7 kg Dimensions 482 x 88 x 300 mm ­ Standard rack 19" 2U Protection IP20 Ambient Temperature  From 0°C to +35°C Not allowed to be fitted on normally inflammable surfaces Applied standards CO670L EN­R0   |   07/2018 WARRANTY CONDITIONS 2009/125/CE  ­  reg.  (UE)  1194/2012,  Energy  label ...