Contents Contents ............................2 Preface ............................. 4 Explanation of terms and index of abbreviations ..............5 Safety ............................6 Use as intended ........................ 6 Target group ........................6 Symbols used in the safety instructions ................6 Safety Instructions ......................7 3.4.1 General safety instructions ...................
Page 3
10.1.1 Saving positions ......................24 10.1.2 How to retrieve a saved position ................25 10.1.3 Calling the menu ......................25 10.1.4 Changing the unit of the height display (Inch – CM) ..........25 10.1.5 Calibrating the height display ..................26 10.1.6 Factory reset .......................
It is essential that the table control unit is installed in accordance with these instructions. Changes to the table frame, table control or accessories and improper use can have a negative effect on safety, function and service life. This operating manual has been written for the table controller STAND.CONTROL C1. Oelschläger Metalltechnik GmbH STAND: 17.06.2019...
2 Explanation of terms and index of abbreviations Abb./Term Meaning Oelschläger Metalltechnik GmbH Controller Table controller STAND.CONTROL C1 Reset position Lowermost mechanical end position of the table Minimal position Lowermost software end position of the table Safety stop Stop position from which onwards a safety zone up to the minimal position starts STAND: 17.06.2019...
Furniture installers, maintenance staff who commission the sit/stand desk in sales rooms or at the final customer. The following knowledge is considered a precondition for the commissioning and installation of the table controller STAND.CONTROL C1: Mechanical and electrical basic knowledge (corresponding illustration) Reading the instructions 3.3 Symbols used in the safety instructions...
3.4 Safety Instructions This operating manual contains safety instructions that inform you about potential hazards and thus facilitate safe operation of the STAND.CONTROL C1. Please be sure you comply with these safety instructions without fail! This section provides you with general safety instructions that do not refer to any specific work step.
Page 8
Caution: You must use the supplied power supply cable! Make sure that the power supply cable is not damaged. Operating the STAND.CONTROL C1 with a damaged electrical cord is prohibited. Danger: Before connecting and disconnecting drives, manual switches, or other accessories to the motor control unit, be sure to disconnect the power cable from the mains without fail.
Danger: If the controller is opened, danger of an electrical shock exists for an extended period of time, even after disconnection from the power supply. In case of a technical defect in the STAND.CONTROL C1, please contact the customer service department of Oelschläger Metalltechnik GmbH. Solutions for easy-to-rectify malfunctions are pro- vided in Section 12.
The STAND.CONTROL C1 must not be improperly handled or used and no changes may be made to the controller. Otherwise the warranty becomes invalid. Please see our General Terms and Conditions of Business for more information.
5 Overview Figure 1: Depiction of the controller and its connections. Surface for type rating plate Surface for company logo RJ45 socket D1 for hand switch, cascading or other accessories RJ45 socket D2 for hand switch, cascading or other accessories Motor connection M1 Motor connection M2 Power supply...
6 Scope of supply and necessary as well as optional accessories Note: Only listed accessories, approved by OMT, may be used. Caution: Connecting unapproved components/accessories can result in damage or malfunctions. 6.1 Delivery scope The delivery scope contains: STAND.CONTROL C1 Other accessories required for operation can be obtained from OMT.
Page 13
RJ45 multi-plugs for expanding the number of device connections: STAND.CONNECT hub connecting cables: STAND.CONNECT connecting cables PC software: CON.STAND (only for service engineers), LIVE.STAND USB connecting cables for connection with the workplace computer: STAND.CONNECT CC STAND: 17.06.2019 9910_Operation_Manual_STANDCONTROL_C1_Rev1v1_EN Seite 13 von 41...
Recycle reusable packaging. 7.2 Installation Assemble the table controller STAND.CONTROL C1 on the underside of your table. The table control- ler is normally fitted with screws below the desktop. Alternatively, it is possible to install the controller with a controller holder if the table-top support frame is already pre-fitted for it, for example, FREE.STAND 9051 (see: 7.2.2).
3. Drill the marked places for the screws with the drilling machine if necessary. 4. Fasten the STAND.CONTROL C1 with the two screws. 7.2.2 Assembly with controller bracket (FREE.STAND 9051) Figure 2: Controller bracket for desktop FREE.STAND 9051. No additional tool is required for fitting the controller with controller brackets. Two controller brackets are required for every controller to be fitted.
Figure 4: Controller fitted in the controller brackets. 7.2.3 Assembly with mounting plate Figure 5: Controller bracket You need the following materials and tools for assembly with these controller brackets: Pencil Drilling machine 2 screws Screwdrivers of a size suitable for the screws Note: The screws are not included in the scope of delivery since they have to be selected depending on the material and the thickness of the desktop.
Page 17
For assembly, keep the following steps in mind: 1. Position the table controller at the desired place. Ensure that the leg space of the user is not constrained. 2. Mark the bore holes with a pencil. 3. Drill the marked places for the screws with the drilling machine if necessary. 4.
8 Commissioning Note: Before commissioning, the controller must be electrically de-energised. Figure 6: Example configuration for a table. 8.1 Connecting the drives If you receive a pre-assembled table-top support frame, in which the columns and the controller are already connected to one another, continue with the instructions in Section 8.2. Connect the motor cables to the columns.
Other accessories - such as the collision sensor - can be connected to the free RJ45 port. If there are more accessories components to be connected to the controller than the number of free sockets, first, the STAND.CONNECT hub must be connected using the STAND.CONNECT connecting cable to one of the free RJ45 ports.
8.4 Initialisation / Reset Caution: During the initialisation movement, the safety mechanisms are disabled. The table moves with reduced speed. Collisions are not detected. Danger: The optionally available corrosion protection is not activated during any reset process. During this process, always watch out for the possible danger of being crushed.
9 Control Caution: The upper end position of the desktop is pre-set in the controller. For this reason, only those controllers that have been supplied as being suitable for the respective desk base may be used. For the operation, a simple hand switch (for example, STAND.MOVE Mx.0) is the minimum require- ment.
2. Press both the arrow keys ( ) at the same time. 3. The controller confirms with one “click-clack” sound. (The absence of this signal means that setting is possibly not permitted.) To delete the container stop, proceed as follows: 1.
9.4 Safety-Stop / Safety zone The safety stop is an additional stop above the minimal position. At this position, the table stops auto- matically when the -button is pressed. To further reduce the table height, first release the button and then press it again.
9.1). 10.1.1 Saving positions The STAND.CONTROL C1 controller provides the user the facility to save up to four heights. This function can only be used with a comfort hand switch. The positions are saved in the controller and are retained even when the hand switch is replaced.
Note: No positions can be saved below an existing container stop. 10.1.2 How to retrieve a saved position Keep the desired memory setting pressed. The desk independently moves from the current position to the saved position. The button has to be pressed until the position is reached; if you let go beforehand, the desk stops moving.
5. Confirm the selection by once again pressing the “Logo” key. 6. The hand switch automatically toggles back to the height display. The setting is permanently saved in the controller and is retained even when the hand switch is replaced. In the absence of any selection or further actions, after approx.
5. Confirm the input by once again pressing the “Logo” key. 6. The menu is exited automatically and is displayed. This code requests an initialization. Perform this according to the instructions in Section 8.4. If no selection is made, after six seconds, the display will automatically return tot he main menu. 10.1.7 Set shelf and container stop (depending on the configuration) Warning: Only trained personnel should carry out the setting of container and shelf stops.
In the absence of any selection or further actions, after approx. 6 seconds, the display automatically switches back to the main menu. 10.1.8 Delete shelf and container stop (depending on the configuration) Warning: Only trained personnel should delete container and shelf stops. There is a danger of injury from removal of the Stop positions, and a danger of the table getting destroyed.
If automatic movement is activated in the controller, positions such as described in section 10.1.2 can be invoked by briefly pressing the relevant position key. The key does not have to be kept pressed the entire time. All other functions are identical. Automatic movement is interrupted by pressing any other key.
10.3 Cascading Caution: The upper end position of the desktop is pre-set in the controller. For this reason, only those controllers that have been supplied as being suitable for the respective desk base may be used. Caution: Use only controllers with identical parameter sets for cascading, since otherwise, unforeseeable behaviour of the table could occur.
Therefore, only agents with a pH value of 6-8 may be used. The STAND.CONTROL C1 can be wiped from the outside with a soft cloth. Coarse soiling may only be removed with a soft, damp cloth. Ensure that no moisture penetrates into the housing.
12 Easy to rectify faults Warning: Before troubleshooting, especially on faulty cables, the controller must be isolated from the network. If a fault cannot be rectified as described, isolate the product from the voltage supply, wait for at least 3 minutes and try again. If the fault continues to occur, isolate the product from the voltage supply and contact our customer service.
Page 33
Fault description Troubleshooting Check the loading of the table. Reduce the weight on the table. STAND: 17.06.2019 9910_Operation_Manual_STANDCONTROL_C1_Rev1v1_EN Seite 33 von 41...
13 Acoustic and visual codes 13.1 Acoustic codes The controller, as soon as it is supplied electric power, can give the user information about the current system status by means of its integrated relay. Table 2: Acoustic codes of the controller. Number of “click- When...
13.2 Visual codes Visual codes can only be used when using hand-switch models with a display. Table 3: Visual codes of the controller Display Description Remedy Pull the mains plug. Correct the exter- nal short-circuit, check the cables to Short-circuit motor 1 the motors for damage or connect the correct motor to the relevant socket.
Page 36
Display Description Remedy The parameters in one controller do not match the number of legs or the parameters are not the same in the Discrepancy in the parameters two controllers. Contact Customer Service and have the parameter set of the table checked.
14 Technical data The technical data of the STAND.CONTROL C1: Rated input voltage 100 - 240 V Rated input frequency 50 – 60 Hz Rated input current consumption 2.5 A Rated input power 250W Standby power at nominal voltage, 0.3 W...
Page 38
STAND: 17.06.2019 9910_Operation_Manual_STANDCONTROL_C1_Rev1v1_EN Seite 38 von 41...
15 Tests and certificates The drive system is tested according to the following standards: Electromagnetic compatibility (EMV-Directive 2014/30/EU): EN 61000-6-2:2005 Electromagnetic Compatibility (EMC) EN 61000-6-3:2007+A1 Electromagnetic Compatibility (EMC) EN 61000-3-2:2014 Electromagnetic Compatibility (EMC) EN 61000-3-3:2013 Electromagnetic Compatibility (EMC) Electrical safety (low voltage directive 2014/35/EU): EN 62233:2008 Safety of persons in electromagnetic fields EN 60335-1:2012+A13...
16 Disposal The FREE.STAND table-top support frame in which the STAND.CONTROL C1 is fitted is an electrical and electronics device that must be disposed of separately from household waste, in accordance with the applicable WEEE-directive 2012/19/EU. Figure 9: Identification markings for products in accordance with WEEE Directive 2012/19/EU Dispose of the product and all other materials and parts in an environment-friendly manner, in accord- ance with the applicable national regulations in your country.
Section 9 for generating the end user documentation for the height-adjustable table, in which the STAND.CONTROL C1 was integrated, for 10 years from delivery, free of charge. This licence does not include any logo, design or page layout elements of Oelschläger Metalltechnik GmbH.
Need help?
Do you have a question about the STAND.CONTROL C1 and is the answer not in the manual?
Questions and answers