DIETZ GSV 544X-xxx/400 DIETZ GSV 544X-xxx/400 Current Converter For Brush-Type DC Motors Attachment Operating Instructions DIETZ DSV 5444, DSV 5445 Lift Edition 04/07 Subject to technical modifications (Interim) Emotron AB 12.04.07 g444_04e.doc...
Page 2
Following the IEEE915 directive line reactors of 4% uk minimum are needed, further information or special solutions will be projected and quotated on request. Emotron Lift Center GmbH Max-Planck-Straße 15 D 72639 Neuffen...
Explanations of parameters 5.6.1 "F0" armature excitation 5.6.2 t rotor time constant 5.6.3 First initialisation flag 5.6.4 Commutating limit parameters F1, F2 and variables 0E6A, 0E6E TIPS, TRICKS Hotline note Technical data for enquiry order Seite 3 12.04.07 Emotron AB...
Page 4
Encoder of inferior quality with high-transistor logic, i.e. output signal has a rectangular shape, but supply voltage is up to 30 V DC. (2 tracks, cannot be monitored) Tracks Number of encoder signals that are displace by 90 ° to each other. Seite 4 Emotron AB 12.04.07...
GSV 5445 to operate high- and low speed DC winches with or without gear. ♦ Software package 3 GSVNIKE.KOM / GSVRBG.KOM / GSVDIG.KOM (menu navigation GSVNIKE.CNF / GSVRBG.CNF / GSVDIG.CNF) system GSV 5444-xxx/400 for shelf access equipment modernisation is projected. Seite 5 Emotron AB 12.04.07...
This short manual is only in conjunction with the corresponding operating instructions for three phase drives valid. There you can find also how to operate this drive and the pin assignment of the input/output clamps. Seite 6 Emotron AB 12.04.07...
Power decrease from 40 °C at 1,5 % per 1 °C (maximum up to 55 °C) ♦ Storage temperature: -20 ...70 °C ♦ Humidity rating E to DIN 40040 ♦ Installation altitude up to 1000m, thereafter power reduction 6% per 1000m Seite 7 Emotron AB 12.04.07...
Field current 0 - 10 A 1,5 mm² 0-20 A 2,5 mm² Brake resistor The dimensioning of the brake resistor has to be verified by means of the lift data! Seite 8 Emotron AB 12.04.07...
DIETZ GSV 544X-xxx/400 4 Power connection Driving via interface only if required. Bridge the clamps 23 and 24 if thermistor is connected to external controller. Connect varistor to brake magnet. Seite 9 Emotron AB 12.04.07...
There must be no contactor in the field circuit. There are only two contactors in the armature circuit, the three pairs of contacts of which are each connected in series in the below exam- ple. Non-binding switching proposal for the power circuit (R3 = 2kΩ 0,5W carbon film): Seite 10 Emotron AB 12.04.07...
"operation mode", if the suitable application has been selected. Is the system e.g. operating with "GSV_NIKE" (shelf access equipment) and you are working with standard application "GSV.KOM", the operation mode has to be changed to "normal" before editing parameters or variables! Seite 11 Emotron AB 12.04.07...
“REQUIRED = ACTUAL”. SET/ACTUAL on F18 F14*0,8 ms gives the period, in which the position must fall within the toler- position SET/ACTUAL scan ance window to set the message “SET = ACTUAL”. Seite 12 Emotron AB 12.04.07...
Page 13
E54 Customised settings. offset analog speed E56 Customised settings. max. digital speed Standardised analog torque E58 Customised settings. E5A Customised settings. hyst. analog torque offset analog torque E5C Customised settings. E5E Customised settings. max. digital torque Seite 13 Emotron AB 12.04.07...
Page 14
( % of I Encoder increments actually only 1024 increments per motor revolution preset Please change the bold values of the factory settings only after well examination resp. after calling back our company. Seite 14 Emotron AB 12.04.07...
If the speed is less than the set value (m/s), then output A2 is set.. At 0,300 speeds less than the set value, following lift function is enabled: "Early opening doors". E16 excess speed Output A3 will be low at V >E16 (start value = 1,15 * V3) 2,850 Seite 15 Emotron AB 12.04.07...
Page 16
Only very dynamical drives cause a switch-off in case of error. E62 emergency evacuation Corresponding to LIFT7TZ. E64 DCP=90,CAN=165,ACP=85 Selection of bus mode. E66 baud rate Selection of baud rate DCP, CAN, ACP E68 SG18-LG18-flag Event memory 0. fault memory 255 Seite 16 Emotron AB 12.04.07...
Page 17
Please change the bold values of the factory settings only after well examination resp. after calling back our company. Detailed information about the parameters and variables you can find in the lift manual l445_21e. Seite 17 Emotron AB 12.04.07...
5.6.3 First initialisation flag The first initialisation flag switches on an effective monitoring to protect the DC motor from the "runaway". If unexpected errors occur when using very high dynamic drives, this monitoring can be switched off. Seite 18 Emotron AB 12.04.07...
110 rpm up to 2 x “F2” = 220 rpm. For 159 rpm this results in 75%. On the other hand the value in “0E6E” has practically no effect since “F1” and “F2” inevitably are close. Seite 19 Emotron AB 12.04.07...
Soft start time too short, run-up rounding too steep Soft speed not matched to static frictional (too high) ♦ With epicyclical gears: Increase I-gain run and P-gain stop ♦ With old worm gears: Select high I-gain run and small P-gain stop ♦ Seite 20 Emotron AB 12.04.07...
Page 21
If the difference between the set point and actual values of the speeds is not too high at high speeds, the first initialisation flag 0E60 can also be set to “0”. In this case the above mentioned monitoring is disabled. Seite 21 Emotron AB 12.04.07...
UP Fault is reproducible during start during deceleration only during travel Fault occurs sporadically during acceleration when stopping DOWN Short description of fault: Seite 22 Emotron AB 12.04.07...
DIETZ GSV 544X-xxx/400 8 Technical data for enquiry order If ordering equipment please always complete this form and mail or fax it to: Emotron Lift Center GmbH, Max-Planck-Straße 15, D-72639 Neuffen Fax: +49-7025-5824, Tel. +49-7025-101-0 Customer and order information Date: Customer address...