E.2 series high
efficiency
circulator
Installation and
operating instructions
File No: 10.84
Date: august 16, 2012
Supersedes: 10.84
Date: july 20, 2010

Advertisement

loading

Summary of Contents for Armstrong E.2 Series

  • Page 1 Part # 182212-663 Tag: PHX-3 Model # E10.2 CI 120V Tag: PHX-4 Model # E10.2 CI 120V Part # 182202-649 Tag: RCP1-3 Model # E12.2B BRZ 120V Part # 182212-842 E.2 series high efficiency circulator Installation and operating instructions File No: 10.84 Date: august 16, 2012 Supersedes: 10.84...
  • Page 3: Table Of Contents

    contents Operating limits Electrical wiring Start up Preventive maintenance – inspection Pump replacement in an existing installation Complete pump Motor end only Mechanical seal replacement...
  • Page 4: Operating Limits

    & oper ating the circulator installer: please leave this manual for the owner’s use You are about to install an E.2 Series circulator – a high– efficiency pump from Armstrong. E.2 Series circulators are designed for heating and cooling in hydronic, geothermal or solar systems and circulating water, ethylene or propylene glycol/water solutions.
  • Page 5: Start Up

    – Typical wiring diagram for including the E.2 Series circulator – for potential problems. If single phase, 120 v, 60 hz power source there is any evidence of leakage or damage, repair or replace the pump.
  • Page 6: Motor End Only

    4 If the entire volute is needed to be removed, then remove 12 To wire the E.2 Series circulator, follow steps C through G in the flange bolts and nuts. The entire circulator can then be the Electrical Wiring section above, noting that electrical removed from the piping system.
  • Page 7 19 If the impeller will not spin freely contact Armstrong seal installation. Technical Support at 1-416-755-2291 or email techsupport@armlink.com.
  • Page 8 t o r o n t o 23 bertrand avenue toronto, ontario canada m1l 2p3 +1 416 755 2291 b u f f a l o 93 east avenue north tonawanda, new york u.s.a. 14120 -6594 +1 716 693 8813 b i r m i n g h a m heywood wharf, mucklow hill halesowen, west midlands...
  • Page 12 FILE NO.: 6010.28 DATE: April 21, 2009 SUPERSEDES: New DATE: Feb. 23, 2006 Circulator Flange Dimensions Individual flanges Armstrong Bell & Gossett Dimensions Cast iron Bronze Cast iron Bronze Diagram P06660 1 ¼” 3 104300-011 104300-041 P03300 4 ¾” ½”...