The terminals on the ENS31 are arranged as follows:
Attention
The ground conductor should always bypass the unit. The neutral con-
ductor MUST be connected to the ENS31 otherwise the unit may be
damaged.
If the ENS31 is switched on and off by means of a system control unit, the
L1 connection of the ENS31 can be switched by means of a relay.
Note
When switching on via L1, the delay until the contactors are activated
can be up to 30 seconds because the ENS31 must test the power feed
conditions again.